Records from 2007 to 2016. Most recent: inspection, 11 August 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
11 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6096854
8 February 2011
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3941581
18 January 2011
MTSA Verification · Ballast Water Examination · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3932096
24 March 2009
Examination of Repairs · Internal Structural Exam · Re-Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3438929
31 March 2008
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3174803
11 March 2008
Re-Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3162034
1 November 2007
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3090961
27 March 2007
MTSA Verification · Construction Oversight · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2895891
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 January 2011
Resolved
Engine room wire runs had numerous areas being held together with only wire ties. Instructed company electrician to remove wire ties and install metal band straps.
Condition: Improper Installation
Due 24 February 2011
Resolved 8 February 2011
Resolution: Installed metal band straps
Lifesaving › Rescue Boat › Markings
Issued 24 January 2011
Resolved
Rescue boat did not have retro on hull bottom.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: Crew placed retro on the bottom of rescue boat.
Engineering › Steering Gear System › Power Unit
Issued 24 January 2011
Resolved
Repair stbd steering tank high temp alarm. Alarm light was constantly on.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: Alarm repaired
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 January 2011
Resolved
Vessel did not have a lifesaving equipment maintenance log.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: Capt created lifesaving equipment log
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 24 January 2011
Resolved
Fire extinguisher brackets in E/R were not mounted. Vessel rep was instructed to permanently mount brackets.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: Brackets were mounted.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 24 January 2011
Resolved
Dirty oil pump suction union was leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: Union was repaired.
Communications › Radio Communications › EPIRB
Issued 24 January 2011
Resolved
When the EPIRB was tested it produced a fault light. Capt was instructed to repair/replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: EPIRB was replaced.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 24 January 2011
Resolved
Found a recreational style sea anchor in rescue boat equipment. Vessel to provide correct sea anchor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: Rescue boat has correct equipment onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 24 January 2011
Resolved
Two lifebuoys require replacement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2011
Resolution: Lifebuoys identified by marine inspector were replaced.
Lifesaving › Line-Throwing Appliances › Lines
Issued 24 March 2009
Resolved
Provide 500' of line for line throwing gun.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2009
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 24 March 2009
Resolved
Renew wire penetrations on split eng. rm. blkhd above water tight door.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 26 March 2009
Lifesaving › Lifefloat › Pendant
Issued 24 March 2009
Resolved
Renew/repair lifefloat lines, attach together with correct length of line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 24 March 2009
Resolved
Clean out all dryer vents.
Action required: 705 - Other - as specified
Due 24 April 2009
Resolved 26 March 2009
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 11 March 2008
Resolved
Provide automation test procedures for approval, include set points and ranges.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 26 March 2009
Engineering › Lubricating Oil Service System › Gauge
Issued 11 March 2008
Resolved
Provide jacking system low hydraulic oil level alarm.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 31 March 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 March 2008
Resolved
Provide e-lights at pilothouse, lifefloat and rescue boat storage.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 31 March 2008
Stability › Watertight Integrity › General
Issued 11 March 2008
Resolved
Provide class 1 QAWTD for E/R centerline with indicator as required by 46 CFR 174.210
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 17 March 2008
Resolution: C/L bulkhead is not WT subdivision bhd, QAWTD not required.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 11 March 2008
Resolved
Provide fixed piping and pump as required by 33CFR 155.420.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 31 March 2008
Documentation › Certificates/Documents › International Load Line Certificate
Issued 27 March 2007
Resolved
Vessel shall be operated in compliance with restrictions listed in memorandum CG-3PSE-2 dated 06Feb07. The permit to operate is pending issuance of a valid load line cert. The vessel is limited to U.S. domestic operations only (not international). Vessel is to be operated in accord. with app. stability ltr. Rest. to not more than 12 hrs from location where it can jack to survive 100kt winds.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 1 November 2007
Resolution: Domestic loadline issued by LR dated 28JUN2007.