Records from 2009 to 2026. Most recent: inspection, 11 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)66.5 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)62.0 ft × 28.3 ft × 9.2 ft
ITC tonnageNot recorded
BuilderISLAND BOATS INC · JEANERETTE, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
23 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; 1 vessel inspected with it, by name and date; 4 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 23
11 May 2026
Internal Structural Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8371280
11 December 2025
In-Service Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8282752
9 June 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8156736
3 June 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8157524
29 April 2025
Examination of Repairs · Drydock Exam · In-Service Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8126404
21 November 2024
In-Service Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8038899
13 May 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7911890
24 December 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7847273
23 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7722828
5 April 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7624239
28 April 2022
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7439616
16 November 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7359118
23 June 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7222722
7 April 2021
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7171235
21 January 2021
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7129652
4 August 2020
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7023559
26 August 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6792817
18 April 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6674701
6 August 2018
Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6502972
5 June 2017
Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6146772
6 April 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6223078
24 July 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5962115
16 May 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5915938
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Seven life jackets dated 2002 were squishy, deteriorated and no longer structurally adequate, unserviceable condition. Provide replacement life jackets in serviceable condition. Reduced passenger count by seven adults.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2023
Resolved 24 June 2023
Resolution: All life jackets replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 June 2023
Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. The vessel only had one method of energizing the fire pump from the bridge, no other local operation was present. Vessel not outfitted with required local operations at the pump, reduced passenger carriage to 49.
46 CFR 181.300(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2023
Resolved 24 June 2023
Resolution: Witnessed tests of the local means of starting the fire pump; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 June 2023
Resolved
Fire hoses and nozzles.
(a) A fire hose with a nozzle must be attached to each fire hydrant at all times. During the test of the fire pump, the hose blew off the fitting making the hose unserviceable. Vessel rep to replace the hose IAW 46 CFR 181.320 (b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2023
Resolved 24 June 2023
Resolution: Sighted new hose nad witnessed pressure test; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2023
Resolved
Vessel required to have one 24" ring lifebuoy fitted with a floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebuoy found unserviceable; plug removed with core material exposed to water. Provide serviceable ring lifebuoy onboard vessel and properly arranged prior to carrying passengers.
46 CFR 180.70(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2023
Resolved 24 June 2023
Resolution: New ring buoy installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2023
Resolved
The employer shall provide an Employee Assistance Program for all crewmembers that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. Crewmembers were unaware of EAP details, company must conduct training with all crew members and submit documentation to the CG to verify completion. Additionally, provide documentation of company's policy or policy statement IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2023
Resolved 27 June 2023
Resolution: All required mandatory training completed to the satisfaction of the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 June 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The port and starboard shafts are exposed and do not have adequate protection over the rotating machinery presenting a hazard. Install suitable protection that does not impede or restrict the operation of the shafts. MI must verify new installation.
46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2023
Resolved 14 July 2023
Resolution: Attended vessel and sightds required guards installed to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 June 2023
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. The gauge was not operational, must replace and test.
46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2023
Resolved 24 June 2023
Resolution: Guage replaced gauge and sighted 60 psi during test; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 April 2023
Resolved
A vessel must comply with the structural design requirements of one of the standards listed.
- Stbd lazarette, pitting found in fwd bulkhead and keel/bottom plate.
- Stbd storage void, pitting found in inboard hull plate, 1/8" hole found in aft bulkhead, pitting found on keel plate forward of swash bulkhead.
- Stbd storage void, pitting found on horizontal portion of two transverse swash bulkheads.
- Port lazarette, pitting found on keel plate adjacent to forward bulkhead.
Provide repair proposal for aforementioned areas to satisfaction of attending Marine Inspector.
46 CFR 177.300 705 C
Action required: 705 - Other - as specified
Due 6 April 2023
Resolved 4 May 2023
Resolution: Repair proposals provided and followed with inserts completed sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 April 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Junction box found with missing front plate. Replace in kind missing plate.
46 CFR 183.200 (c) 705 C
Action required: 705 - Other - as specified
Resolved 10 May 2023
Resolution: Front plate replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 April 2023
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Cracked
weld found on swim ladder where vertical stanchion meets
handrail. Scarf and renew weld.
46CFR177.300 705 C
Action required: 705 - Other - as specified
Resolved 4 May 2023
Resolution: Swim ladder renewed weld.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 April 2023
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. 3 sections of hand rails on second deck were missing screws. Replace screws in identified sections.
46 CFR 177.900 (b)
Action required: 705 - Other - as specified
Resolved 10 May 2023
Resolution: Screws replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2023
Resolved
During the examination all accessible parts of the vessels underwater body and all through hull fittings including the propellers, shafts, bearings shall be made available for examination. Clean propellers to make ready for inspection.
46 CFR 176.610 (a) 705 C
Action required: 705 - Other - as specified
Resolved 4 May 2023
Resolution: Propellers cleaned and inspected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023
Resolved
When required by the marine inspector, a portion of the inspection must be conducted while the vessel is underway. Conduct sea trial prior to credit drydock.
46 CFR 176.802 (c) 705 C
Action required: 705 - Other - as specified
Resolved 10 May 2023
Resolution: Sea trial completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2022
Resolved
Each vessel must have permanent draft marks at each end of the vessel or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and admidships to indicate the maximum allowable drafts. Vessel does not have draft marks or loading marks as required by the stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2023
Resolved 10 May 2023
Resolution: Vessel has provided proper draft marks.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 26 August 2019
Resolved
Replace three ring buoys with proper retroflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 26 August 2019
Resolution: Marine Inspector verified proper retroflective tape on ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 August 2019
Resolved
Place life jacket donning placard on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 26 August 2019
Resolution: Marine Inspector verified life jacket donning placard on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2019
Resolved
Battery connections must be made to battery terminals with permanent type connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 26 August 2019
Resolution: Marine Inspector verified permanent type connections on battery terminal.