MAURY USCG vessel records Sign in
← All vessels

VARAMO

VARAMO is a 2007 freight ship. The Coast Guard has recorded 39 inspections since 2007, most recently in August 2021, along with 10 deficiencies and 15 operational controls.

Records from 2007 to 2021. Most recent: operational control imposed, 23 August 2021.

Built
2007
Last inspected
23 August 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9395044 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
874649
Flag
CYPRUS
—
Maury page id
psix-874649

Inspections, by type

…with no type recorded14
Years with a record 9 calendar years (2007–2021)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it15375 - Convention (Subpart B), Gross Ton
15375 - Regulatory (Subpart C or D), Gross Ton
5983 - Convention (Subpart B), Net Ton
18464 - Dead Weight, Ton
5983 - Regulatory (Subpart C or D), Net Ton
25324 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

23 August 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7294034
21 August 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7293001
11 March 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7154773
9 March 2021 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7152720
8 October 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7073852
3 May 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6947554
21 February 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6912292
9 August 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6776873
18 May 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6686940
15 May 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6685057
14 May 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6683868
5 October 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6555421
20 September 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6545074
11 August 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6508182
7 August 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6503451
20 July 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6485516
14 June 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6444136
26 March 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6378688
13 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6286845
24 September 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6269973
24 September 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6273674
15 August 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6241087
10 August 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6236771
13 December 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6056931
19 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6004139
6 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5993226
9 August 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5967495
29 February 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5824307
23 June 2014 PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4897248
19 June 2014 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4888868
3 March 2014 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4808925
1 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3444494
1 April 2009 Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3444637
1 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3488417
13 January 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3392794
18 December 2007 ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3117572
14 March 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2887107
13 March 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2885312
13 March 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2887415

Deficiency record · 10

10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 15 May 2019 Resolved
A gyro-compass, or other means, to dertermine and display their heading by shipborne non-magnetic means. Gyro-compass is malfunctioning, no data infomation at the main gyro control and display unit.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 16 May 2019
Resolved 18 May 2019
Resolution: VESSEL PROVIDED TECHNICIAN REPORT ATTESTING TO THE PROPER OPERATION OF THE GYRO. SECMIA ADMINISTRATIVELY REVIEWED AND APPROVED CORRECTIVE ACTIONS. SEE DOCUMENTS FOR REPORT.
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 September 2017 Resolved
Emergency generator set shall be equipped with a second source of power for starting. Second set of batteries were found with low voltage and were unable to provide the generator with enough amps to start generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2017
Resolution: Vessel replaced emergency generator batteries. Class Surveyor in attendance approved of the batteries.See Class Survey Report attached.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 24 September 2017 Resolved
Cargo ships engaged on international voyages shall be fitted with a voyage data recorder. Annual VDR certificate was not onboard vessel & last service report checklist could not check batteries due to abnormally high temperatures.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 October 2017
Resolution: Rcvd correspondence from class attesting to repairs to VDR to complete the VDR Annual performance Test. See Documents for class report.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 24 September 2017 Resolved
Proper navigational charts shall be provided for area of operation. Vessel did not have the proper chart for Port Canaveral.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2017
Resolution: Vessel obtained Navigational charts for Port Canaveral.
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 September 2016 Resolved
1530 - All ships of 3,000 GT and upwards shall have a 3 GHz radar. Radar was reported inoperable. 74 SOLAS (2014 CONS) V/19.2.7.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 30 September 2016
Resolution: Received DNV-GL Survey attesting that the S band radar had been repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 19 June 2014 Resolved
0725 - Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. On CO2 tanks 12 and 13, the high pressure discharge hose attached to the CO2 manifold via a reducer, are severely corroded due to a condensation leak from the CO2 room's ventilation. The connection point has three dissimilar metals accelerating the corrosion. SOLAS 74 (con ed 09)
Action required: 705 - Other - as specified
Due 19 July 2014
Resolved 2 July 2014
Resolution: Received report from [name withheld] stating that Panama Marine Safety and Supply has replaced the discharge hoses on the CO2 manifold. Deficiency is cleared.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 19 June 2014 Resolved
0615 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. While conducting the deck examination portion of the PSC exam the PSCO had the crew test their rescue boat engine, the crew was unable to start the engine after multiple attempts. SOLAS 74 (con ed 09) III/20.2
Action required: 705 - Other - as specified
Resolved 20 June 2014
Resolution: Received notification from class that rescue is operational. Rescue boat engine has a class condition to receive maintenance while in Norfolk.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 19 June 2014 Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Instructions for maintenance of life-saving appliances shall be easily understood. While reviewing the vessel's SMS manual there was no maintenance for the rescue boat engine. ISM SOLAS (con ed 09) IX/3.1 CODE 10.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2014
Resolution: Received documentation from class attesting to the correction of the above deficiency.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 1 April 2009 Resolved
Ship experienced an overpressurization in the main diesel engine's crankcase causing all crankcase relief valves to relieve. Provide class report describing cause and attesting to the satisfactory operation of the ship's main engine including but not limited to the fuel & lube oil service systems. To be completed prior to moving from Long Beach berth G229.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2009
Resolution: Satisfactory class letter recieved: Dock trials conducted at 1900 on 8/21/09. Present during dock trials were MAN B&W, ship''s Fleet Manager and engineering personnel. Dock trial successful as engine performed satisfactory and proved fuly functional.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 1 April 2009 Resolved
Satisfactory sea trials must be conducted to verify proper operation of the main diesel engine by the vessel's class society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2009
Resolution: Received Class report attesting to successful sea trails

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.