← All vessels
PLOUTOS
PLOUTOS is a 2006 tank ship. The Coast Guard has recorded 18 inspections since 2007, most recently in May 2026, along with 25 deficiencies and 3 operational controls.
Records from 2007 to 2026. Most recent: inspection, 12 May 2026.
- Built
- 2006
- Last inspected
- 12 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9327023 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6VO3
874684
Flag
BAHAMAS, THE
—
Maury page id
psix-874684
Inspections, by type
…with no type recorded4
Years with a record
9 calendar years (2007–2026)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it42048 - Convention (Subpart B), Gross Ton
22309 - Convention (Subpart B), Net Ton
73711 - Dead Weight, Metric Ton
89381 - Displacement, Metric Ton
22309 - Convention (Subpart B), Net Ton
73711 - Dead Weight, Metric Ton
89381 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
12 May 2026
COC-TVE Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8371501
21 September 2024
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8006713
3 August 2024
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7973395
2 July 2024
PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7942868
12 September 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7787716
25 April 2023
COC-TVE Annual · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7674412
1 January 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7612205
26 December 2022
Administrative Inspection · COE-Administrative
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7613110
29 April 2022
PSC B · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7611896
28 August 2019
Deficiency Check · COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6796885
10 August 2017
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6234387
18 May 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5880620
14 March 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5832625
12 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5831760
24 February 2016
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5820774
2 May 2014
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4848674
11 March 2007
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · COC-TVE Renew · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2885598
10 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2885435
Deficiency record · 25
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 August 2019
Resolved
In tankers, a system for continuous monitoring of the concentrations of hydrocarbon gases shall be fitted. Sampling points or detector heads shall be located in suitable positions in order that potentially dangerous leakages are readily detected. Two sampling heads in the pump room were exhibiting electrical faults and not reading measurements accurately.
74 SOLAS (2004) II-2/4.5.10.1.3
Prior to conducting cargo ops
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 August 2019
Resolved
The high level alarm must activate a visible and audible alarm so that it can be seen and heard on a vessel where cargo is controlled. High level visual and audible alarms are not operational on deck.
46 CFR 39.2067
Prior to loading cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 August 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. IGG drain line from blower was sheared off and no longer connected.
74SOLAS (2014) I/11 (a) 16AC
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 28 August 2019
Resolved
Oil residue (sludge) may be disposed of directly from the oil residue (sludge) tank(s) to reception facilities through the standard discharge connection or to any other approved means of disposal of oil residues (sludge), such as an incinerator, auxiliary boiler or other acceptable means annotated in item 3.2 of the supplement to IOPP form A or B. According to the oil record book part 1, the vessel transferred sludge from dirty fuel oil tank to No 1 HFO settling tank on 27Aug2019 and 19Aug2019.
MARPOL Annex I/12.2 17AC
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2019
Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. The pilot cylinders on the fixed High Pressure CO2 system has not been hydro tested since 2005.
74 SOLAS (2009) II-2/14.2.1.2 17AC
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 28 August 2019
Resolved
Machinery...associated piping systems and fittings shall be installed to reduce to a minimum any danger to persons on board, with due regard to moving parts, hot surfaces, and other hazards. The Main engine's cylinders 2,4, and 5 fuel pumps were leaking fuel oil. Additionall, cylinder 5 was found to be leaking jacket cooling water.
74SOLAS (2004) II-1/ 26.1
17AC
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 August 2019
Resolved
The fire resistance of doors shall be equivalent to the division in which they are fitted. Doors fitted in boundary bulkheads of category A shall be reasonably gastight and self closing. Numerous self closing doors of class A as listed in the vessels Fire Control Plan do not properly close and latch including A-60 doors to E/R from AC room and from E/R to steering gear. A-0 doors to fire locker on upper deck, CCR, deck and engine changing rooms, and hydro pump room.
74SOLAS(2009) II-2/9.4.2.1 50AC
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 August 2019
Resolved
A main electrical lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by passengers or crew shall be supplied from the main source of electrical power.
Multiple lighting and emergency lighting fixtures were found to be inoperable. Some fixtures contained water, some lacked grounding wire.
74 SOLAS 14/41.2.1 17AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019
Resolved
The machinery..associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts hot services and other hazards.
On the steering gear system, a hydraulic oil leak was identified on the piping outlet side of the #1 pump.
74 SOLAS 14 II-1/26.1 50AC
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 August 2019
Resolved
After any survey of the ship under regulations 7.8.9 or 10 has been completed, no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without sanction of the Administration. An unapproved light fixture has been added above the workbench in the electrical workshop in the engine room.
74 SOLAS (2014 Cons) 1/II (b) 40AC
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 August 2019
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Both port and starboard deck lines are unpainted.
ICLL 66/Anexx 1 Regulation 8 40AC
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 August 2019
Resolved
Every radio installation shall be clearly marked with the call sign, ship station ID, and other information. The CCR VHF radio was missing the vessels MMSI number.
74 SOLAS (2014) IV/ 6.2.5 10C
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 August 2019
Resolved
Vessels of 400 gross tons and upwards shall be fitted with at least 1 international shore connectional meeting the requirements of the code. Washers were missing from the international shore connection in the fire locker.
74 SOLAS (2004) II-2/ 10.2.1.7.1 10C
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 August 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. One of the fire dampers in the gymnasium was missing its handle. 74 SOLAS (2014) I/11 (a) 40AC
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 August 2019
Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off power before the davit arms reach the stops. The limit switch on the port side lifeboat (which is also the rescue boat) was not operational.
74 SOLAS (2014) III/ 16.1
LSA VI/ 6.1.2.7 10C
Deck/Cargo › Inert Gas System › IGS Blower
Issued 10 August 2017
Resolved
ATLEAST TWO INERT GAS BLOWERS SHALL BE FITTED AND BE CAPABLE OF DELIVERING TO THE CARGO TANKS ATLEAST THE VOLUME GAS REQUIRED. INERT GAS BLOWER #1 WAS UNABLE TO START AND MAINTAIN OPERATION. 74 SOLAS (04) II-2/4.5.5.1.1 FSS CODE CH15 2.3.1.4.1
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 10 August 2017
Resolved
INSTRUMENTATION SHALL BE FITTED FOR CONTINUOUSLY INDICATING AND PERMANENTLY RECORDING THE OXYGEN CONTENT OF THE INERT GAS. OXYGEN ANALYZER WAS UNABLE TO BE CALIBRATED AND PROVIDE ACCURATE OXYGEN CONTENT READING. 74SOLAS(04) II-2/4.5.5.1.1 FSS CODE CH15 2.2.4.2.2
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 10 August 2017
Resolved
MATERIALS USED IN INERT GAS SYSTEMS SHALL BE SUITABLE FOR THEIR INTENDED PURPOSE. DISCOVERED PINHOLE LEAKS IN FLUE GAS INLET PIPING. 74SOLAS(04) II-2 4.5.5.1.1 FSS CODE CH15 2.2.1.3
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 10 August 2017
Resolved
CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PINHOLE LEAKS WERE DISCOVERED ON THE TOP SIDE OF THE MARINE SANITATION DEVICE. 74SOLAS(14) I-11(a)
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 August 2017
Resolved
CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PINHOLE LEAKS WERE DISVCOVERED ON THE OILY WATER SEPERATOR. 74SOLAS(14) I/11(a)
Deck/Cargo › Inert Gas System › IGS Blower
Issued 10 August 2017
Resolved
CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. UNNAPROVED SOFT PATCHES WERE DISCOVERED ON THE INERT GAS BLOWER LINE. 74SOLAS(14) I/11(a)
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2017
Resolved
CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. UNNAPROVED SOFT PATCHES WERE DISCOVERED ON THE SALT WATER COOLER FOR THE MDE. 74SOLAS(14) I/11(a)
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 10 August 2017
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE ALL LIFE-SAVING APPLIENCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. APPROXIMATELY HALF OF ALL LIFE JACKETS HAD DIM LIGHTS COMPARED TO THAT OF A NEW ONE. 74SOLAS(14) III/20.2
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 24 February 2016
Resolved
Drain pipe on cargo pump #2 has a substantial leak of cargo. A temporary clamp has been placed over the drain pipe. operation of cargo pump #2 must be secured until classification approval. *Rectify deficiencies prior to next us port after sailing foreign.*
Accommodation/Occupational Safety › Ventilation › General
Issued 11 March 2007
Resolved
Provide a NFPA Marine Chemist Certificate to show that the cargo pump room is safe for entry, prior to departure. Coast Guard to enter pump room, no latter than 24 hours after issuance of Marine Chemist Certificate.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National