PELAGIC TAIMEN

PELAGIC TAIMEN is a 2006 tank ship. The Coast Guard has recorded 18 inspections since 2016, most recently in August 2023, along with 10 deficiencies and 2 operational controls.

Records from 2016 to 2023. Most recent: inspection, 11 August 2023.

Built
2006
Last inspected
11 August 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 August 2023
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9350850
874738
Flag
LIBERIA
Maury page id
psix-874738

Documentation record

Tonnage as PSIX records it30053 - Convention (Subpart B), Gross Ton
62032 - Displacement, Metric Ton
50885 - Dead Weight, Metric Ton
13712 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

11 August 2023 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7765580
16 March 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7652127
10 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7607196
20 September 2022 PSC C
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7562703
10 August 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7529725
10 August 2022 PSC B · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7530257
29 April 2022 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7443809
26 July 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7269379
23 July 2021 PSC B · MARPOL Annex VI Survey · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7265284
22 July 2020 Deficiency Check · COC-CHEM Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7012034
24 December 2018 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6602298
2 February 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6348706
24 November 2017 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6310599
12 June 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6170876
12 June 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6174586
31 March 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6115021
9 January 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6067864
1 November 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6033488

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 August 2022 Resolved
FOR THIS PURPOSE, THE FOLLOWING FUNTIONAL REQUIREMENTS SHALL BE MET, MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS.PSCO OBSERVED FUEL OIL LEAK FROM FILTER. 74SOLAS(04)I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 16 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2022 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ESNSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD.PSCO OBSERVED WHILE IN THE ENGINE ROOM A JACKET WATER LEAK ON THE NR1 GENERATOR AT A RATE OF APPROXIMATELY 3 DROPS PER SECOND. WHILE ON DECK, FOUND CRACKED PIPING IN THE FRESH WATER LINE. 74SOLAS(04) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2022
Resolution: ABS surveyor attended vessel at pemex terminal and verified the repairs of the cooling water leaking on the #1 generator.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2020 Resolved
The condition of the ship and its equipment shall be maintained to confrom with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The PSCO observed a leak on the gray water pipe that leads to the MSD tank. The leak was approixmately a gallon per minute. 74 SOLAS (14) I/11(a) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2020
Resolution: Vessel replaced four foot section of pipe. See class report for details.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 July 2020 Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flamable products. PSCO identified unapproved fitting on explosion proof lighting fixture on deck. Lighting fixture located on stbd forward collision bulkhead. 74 SOLAS(14) VII/10.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2020
Resolution: Gland was found to be deformed by surveyor. Vessel replaced with appropriate gland. See Class report for details.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 July 2020 Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO identified explosion proof lighting with debris inside of casing. Lighting fixture located centerline forward of collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2020
Resolution: Vessel disassembled and and cleaned. Fixture was water tested to the satisfaction of class surveyor. See class report for details.
Lifesaving › Launching Appliances › Release Mechanism
Issued 24 November 2017 Resolved
0613 - 74SOLAS(14)III/34, LSA 6.1.1.8 - A lifeboat launching appliance shall be capable of recovering the lifeboat wuth its crew. During abandon ship muster, lifeboat was lowered to embarkation deck. Crew was unable to return lifeboat to stowed position. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2017
Resolution: Class Report Provided, Uploaded in documents.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 January 2017 Resolved
Plans shall be kept up to date. The issued key for the fire control plan does not match current symbols on the fire control paln.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2017
Resolution: Fire plan edited to include missing information.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 3 November 2016 Resolved
At least two blowers shall be fitted, for systems with IGG the Administration may permit only 1 blower if the capacity os sufficient. IGG System has two blowers installed, but blower number 1 could not be operated.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 3 November 2016
Resolution: Electrical issue was resolved and #1 IGG Blower was able to be demonstrated as operational to USCG examination team
Fire Fighting › Structural - A Class Divisions › Doors
Issued 3 November 2016 Resolved
Doors required to be self closing shall not be fitted with hold backs. The fire doors leading from the officers mess to the galley and from the crews mess to the galley have installed holdbacks.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2017
Resolution: A marine inspection attended the vessel and verified that the doors from the Officer's mess room leading to the galley can have installed hold backs. As the written requirement for prohibited hold backs is for machinery spaces.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 3 November 2016 Resolved
Suitable means shall be provided for the zero and span calibration of both fixed and portable cas concentrationmeasurement Instruments. Vessels engineers were unable to demonstrate proper calibration of the inert gas generator Oxygen sensor. Following final attempt to calibrate, when the IGG was in operation -3% O2 was shown.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2017
Resolution: A marine inspector attended the vessel and conducted a calibration test for the inert gas generator, verifying the O2 sensor. A service report was also provided from an outside company, verifying the the correction of the oxygen sensor.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.