Records from 2011 to 2021. Most recent: operational control imposed, 6 October 2021.
Documentation record
Registered dimensions (L × B × D)55.1 ft × 20.9 ft × 4.7 ft
Registered tonnagegross 46 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIBERTY SHRIMP & OYSTER CO INC · GOLDEN MEADOW, LA, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLULING, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 March 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 October 2021
No resolution recorded
All smoke and fire detection systems, including detectors and alarms, must be tested. The fire control panel was last inspected in 2018 and was actively showing a “fault” alarm.
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 October 2021
No resolution recorded
Means must be provided for stopping each fan in the ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Observed that all air vents on the main deck were missing closure covers.
Action required: 30 - Ship detained
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 6 October 2021
No resolution recorded
Rails or equivalent protection must be installed near the periphery of all decks accessible to the crew. No handrails or hand grabs are available for crew use.
Action required: 30 - Ship detained
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 October 2021
No resolution recorded
Any exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Numerous pieces of engine room equipment were missing guards including pumps and turbos on both main engines.
Action required: 30 - Ship detained
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2021
No resolution recorded
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Numerous wire connections in the engine room were made using electrical tape, alligator clips, and were not meeting standards to prevent disconnection or accidental contact. Exposed electrical wiring on the portable water pump controller on the main deck and on several junction boxes, controllers, and electrical panels in engine room.
Action required: 30 - Ship detained
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2021
No resolution recorded
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port and starboard generator windings coated with oily residue.
Action required: 30 - Ship detained
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2021
No resolution recorded
A continuous supply of clean fuel must be provided to main propulsion engine and generators. Observed green growth in fuel filters on main engines.
Action required: 30 - Ship detained
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 October 2021
No resolution recorded
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Observed holes rusted through creating opening from the main deck to the engine room.
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 October 2021
No resolution recorded
Each towing vessel must be maintained and operated so as to minimize fire hazards. Vessel was operating main engines and generator from a portable fuel tank that was placed on the main deck.
Action required: 30 - Ship detained
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 6 October 2021
No resolution recorded
There must be an individual holding an appropriate license as or a valid MMC with endorsement as master in command of each of the following vessels: Every towing vessel of at least 26 feet or more in length. No master was onboard the vessel, the unlicensed deckhand who was onboard stated that he move the vessel 1 mile to its current location.
Action required: 30 - Ship detained
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 October 2021
No resolution recorded
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States, or coastwise trade, must have a Certificate of Documentation. The vessels COD expired in 2018.
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 October 2021
No resolution recorded
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months.
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 October 2021
No resolution recorded
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Identified excessive amounts of oil and fuel throughout the entire engine room bilge, up to 12 inches, posing an imminent fire hazard to the crew & environment.
Action required: 30 - Ship detained
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 6 October 2021
No resolution recorded
Each towing vessel must be capable of preventing all oil spills from reaching the water. We found up to 12 inches of oil in the large engine room bilge and two automatic submersible pumps placed in the bilge, of which one was observed to have a hose leading from the engine room bilge to the overboard discharge and the pump was plugged in; sheen was observed in the waterway. Unplugged pump and had vessel secure power.
Action required: 30 - Ship detained
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 October 2021
No resolution recorded
To stop the flow of fuel in line in the event of a fire or break in the fuel line, a remote fuel shut-off valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Remote fuel shutoff valves on the installed fuel tank were not hooked up. Vessel was operating from a portable fuel tank on the main deck with flexible hoses running through a corroded hole in the hull.
Action required: 30 - Ship detained