Inspection history · 20
22 June 2025
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 8165871
17 August 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7770256
24 May 2023
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7710290
9 February 2023
Administrative Inspection · DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7634310
26 January 2023
Administrative Inspection · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7629468
7 August 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7527452
10 December 2021
Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7401096
21 October 2021
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7341070
1 May 2021
Examination of Repairs · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7261684
16 September 2020
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7108811
22 June 2020
Administrative Inspection · Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6983301
18 October 2019
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6837006
20 May 2019
Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6700022
8 November 2018
Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6577798
7 August 2017
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6221047
10 May 2017
Drydock Exam · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6142727
23 November 2016
In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6046453
9 September 2016
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5995043
25 April 2016
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5861596
21 April 2016
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5858955
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 August 2023
No resolution recorded
46 CFR 176.600(c)(1): A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years Vessel's dry dock for credit is overdue as of 31MAY2023.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 26 January 2023
No resolution recorded
At next scheduled dry dock, 31MAY2023, remove wood rot and angel hair in overhead deck frames in engine room compartment and replace with new/repair to as original to the satisfaction of the attending USCG MI.
Action required: 705 - Other - as specified
Due 31 May 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 26 January 2023
No resolution recorded
Replace broken handle on forward emergency hatch cover to as original. Hatch cover is still able to close using the other handle but does not make it weathertight. Per vessel's captain/owner [name withheld], a new emergency hatch cover will have to procured. Lead time is 2 to 3 months. Replace or repair to as original.
Action required: 705 - Other - as specified
Due 31 May 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 26 January 2023
No resolution recorded
Prove operation of starboard fuel shutoff valve to the satisfaction of the [name withheld] fuel shutoff valve is seized in the open position.
Action required: 705 - Other - as specified
Due 6 February 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2023
No resolution recorded
Vessel missing 5 adult life jackets. COI requires 25 adult life jackets to be carried on board and maintained
per total lifesaving equipment. Pending 25 adult life jackets due no later than 28FEB2023 for inspection; vessel is limited to carrying no more than a total of 20 persons (crew and passengers combined).
Action required: 705 - Other - as specified
Due 28 February 2023 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2023
No resolution recorded
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 and restrictions in paragraphs (1) – (3) respectively. Replace non-USCG approved fuel hoses with hoses that meet SAE J-1942.
Action required: 705 - Other - as specified
Due 3 March 2023 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 January 2023
No resolution recorded
Flexible hoses installed no more than 30 inches subject to pressure of not more than 5 psig and designed with hose clamps, may be installed with two clamps at both ends which do not rely on spring tension of the clamp and are installed beyond the bead, etc. Operator to prove port and stbd fuel supply hose from fuel filter to engines are not more than 30 inches subject to pressure of not more than 5 psig and ends are installed in accordance with cite.
Action required: 705 - Other - as specified
Due 3 March 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2023
No resolution recorded
IMO Res A.658(16) Annex 2 (3.1) The brightness of the retro-reflective material when tested should be not less than 80% of its original installation. Retroreflactive material is worn. Replace 4 x adult PFDS with new as required.
Action required: 705 - Other - as specified
Due 28 February 2023 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 October 2021
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch covers are not tethered to vessel to prevent loss. Replace missing hinges on port side engine room hatch cover and aft hatch cover. Install a captive chain or cable to the aft hatch cover to prevent its loss.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Photo of captive devices and video submitted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Replace missing handle on washroom door to close/open from either side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: New washroom handle on outside of door installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Repair and prove operation of forward cabin light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Video showing light working with switch turned on and off.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2021
Resolved
Waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Replace missing non-combustible trash can for collecting trash.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Vidoe showing new non-combustible trashcan onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2021
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. Vessel rep. reported official log book was water damaged. Replace with new and document required drills, passenger count/trips, prevent maintenance, including EPIRB monthly tests per 46 CFR 185.728.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 December 2021
Resolution: Photo of new log book labled with vessel's name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2021
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Prove operation of aft steering bilge pump in manual mode. Repair or replace as required.
Action required: 10 - Deficiency Rectified
Resolved 26 October 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 November 2018
Resolved
46CFR182.530: High water alarm for aft steering compartment inoperable. Audible alarm still works.
Action required: 705 - Other - as specified
Due 17 November 2018
Resolved 16 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 November 2018
Resolved
46CFR182.720(e)(v)(B):Raw water inlet hose to reduction gear cooler and bilge pump overboard discharge hose in aft steering compartment are equipped with a single hose clamp on each side. Install double hose clamps on all hoses ends connected to the skin of the vessel.
Action required: 705 - Other - as specified
Due 17 November 2018
Resolved 16 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 August 2017
Resolved
Double clamp raw water inlet/discharge hoses.
Action required: 705 - Other - as specified
Resolved 7 August 2017
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 August 2017
Resolved
Replace missing inspection watertight covers on deck above fuel hoses on port and starboard gunnel.
Action required: 705 - Other - as specified
Resolved 7 August 2017
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2017
Resolved
Replace damaged life ring buoy with light with new.
Action required: 705 - Other - as specified
Resolved 31 August 2017
Operations/Management › Vessel Activity › Construction/Repair
Issued 23 November 2016
Resolved
46 CFR 176.700: O/O at own discretion will replace existing engines with in-kind. In-service inspection and sea trial to be conducted prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Power and sea trials completed satisfactory.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 September 2016
Resolved
46 CFR 183.340 (b)(4) All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Cables and wires secured with plastic strap ties.
Due 9 September 2016
Resolved 9 September 2016
Resolution: Corrected to the satisfaction of the MI.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 September 2016
Resolved
46 CFR 182.100: Verify cause of oil leak from port side engine and permanently secure.
Due 9 September 2016
Resolved 9 September 2016
Resolution: Corrected to the satisfaction of attending MI.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 September 2016
Resolved
46 CFR 176.800: Make permanent repairs to overhead lighting fixture in forward cabin space; space is used to store life saving and emergency equipment.
Due 12 September 2016
Resolved 15 September 2016
Resolution: Vessel representative replaced light fixture with new.
Lifesaving › Work Vest › Readily Accessible
Issued 9 September 2016
Resolved
46 CFR 180.72: Make available work vest for crew during parasailing operations on aft/raised platform.
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 18 October 2016