The 1 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for RIO ATRATO, retrieved 18 September 2026. mauryrecords.com/v/psix-876019.html
Documentation record
Tonnage as PSIX records it1274 - Convention (Subpart B), Net Ton 4999 - Dead Weight, Ton 4248 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 1
3 July 2007MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2975730
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 3 July 2007Resolved
Electro-motor for emergency fire pump is burned out. Em. fire pump is currently under repair to return to service. Vessel is unable to provide fire main pressure from outside engine room. SOLAS 60 (unamended) II-2/5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2007
Resolution: Witnessed satisfactory operation of emergency fire pump.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 3 July 2007Resolved
Tank high level/ overfill alarms operate only in certain weather conditions; one gauge was unable to be tested. Vessel cannot accurately determine tank levels in all conditions. 33 CFR 155.480
Action required: 705 - Other - as specified
Resolved 31 August 2013
Resolution: Tested all high level and overfill alarms. All worked satisfactory.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 3 July 2007Resolved
Switches for emergency generator switchboard are not in working language of the crew. Chief Engineer unable to explain purpose of all switches. SOLAS 2004 (cons. ed.) I/11
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 31 August 2013
Resolution: Observed switches and instructions are in the working language of the crew.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 3 July 2007Resolved
Heats sensors for two cylinder heads are inoperative. Parts are on board and uninstalled. Lack of accurate temperature detection creates heightened fire risk. Class machinery survey is currently in progress. SOLAS 2004 (cons. ed.) I-11
Due 3 August 2007
Resolved 31 August 2013
Resolution: Observed operational sensors. Vessel has had multiple surveys since installation in 2007 when deficiency was issued.