MAURY USCG vessel records Sign in
← All vessels

GLORIA A

GLORIA A is a 2007 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2007, most recently in May 2026, along with 11 deficiencies and 2 casualty investigations between 2010 and 2026.

Records from 2007 to 2026. Most recent: inspection, 11 May 2026.

Built
2007
Last inspected
11 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7452
876461
Flag
UNITED STATES
367186630
Maury page id
psix-876461

Inspections, by type

…with no type recorded3
Years with a record 17 calendar years (2007–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)163.0 ft × 30.0 ft × 14.0 ft
Registered tonnagegross 97 / net 65
ITC dimensions (L × B × D)163.0 ft × 30.0 ft × 14.0 ft
ITC tonnagegross 416 / net 124
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it416 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
124 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7452MMSI 367186630 · active · compulsorily equipped · granted 9 March 2017, expires 11 May 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

M/V TAYLOR RENE Commercial Fishing Vessel · MISLE 47396 · 15 September 2010 · activity 3941430

Inspection history · 28

11 May 2026 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8371233
11 May 2026 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8373077
23 June 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8165084
5 June 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8150314
20 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7916444
21 June 2023 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7719847
5 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7704053
10 May 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7680536
12 April 2022 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7420752
14 April 2021 Drydock Exam · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7174873
23 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6984392
23 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6691318
7 May 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6678245
11 July 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6475824
23 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6342197
13 April 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6123540
10 April 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6123242
6 June 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5898728
27 June 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4900308
9 May 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4306488
19 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4227868
15 September 2010 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3850761
15 September 2010 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3941430
5 May 2009 Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3467668
23 July 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3276603
25 December 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3134379
8 May 2007 Initial Construction-Excluding Oversight · Inclining Experiment · Hull Examination · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2924983
17 April 2007 Plan Review "T" Boat
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2910116

Deficiency record · 11

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2026 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the condition of the shafting and bearings are in question. Vessel lost propeller when getting underway. Vessel is permitted a one time voyage to Superior Shipyards Golden Meadow to enact repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2026
Resolution: Satisfactory repairs were completed at shipyard.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 June 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Found "dead end" wire to port steering pump filter housing transducer.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 23 June 2025
Resolution: Vsl rep reconnected wiring IAW best engineering practices.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2023 Resolved
A self priming power driven fire pump must be installed on each vessel of more than 65’ in length. Fire pump motor not working. Repair fire pump.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 June 2023
Resolution: Vessel was able to get new fire pump motor installed while inspection was taking place. Fire pump tested SAT 78 psi.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 6 June 2023 Resolved
Each entrance to a space storing CO2 Cylinders, a space protected by CO2 systems must be conspicuously marked IAW 46CFR185.612(g)(1)(2) doors leading into the E/R and CO2 storage space have no marking. Label doors IAW above reference.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 June 2023
Resolution: Vessel provided proof that proper placards were placed at entry ways to protected spaces.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 April 2022 Resolved
Where an exhaust pipe passes through a watertight bulkhead, the watertight integrity of the bulkhead must be maintained. Cracked welds were identified where the engine exhaust piping terminates into the hull on the aft port exhaust and both starboard exhaust piping. Make temporary repairs within 2 weeks to the satisfaction of the Coast Guard. 46 CFR 182.430(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 25 April 2022
Resolution: Made temporary repairs.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 April 2022 Resolved
Where an exhaust pipe passes through a watertight bulkhead, the watertight integrity of the bulkhead must be maintained. Cracked welds were identified where the engine exhaust piping terminates into the hull on the aft port exhaust and both starboard exhaust piping. Make permanent repairs by next drydock 30APR2023 to the satisfaction of the Coast Guard. 46 CFR 182.430(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2023
Resolved 21 June 2023
Resolution: verified Def from previous COI were complete. Vessel had made Permanente repairs to the ships exhaust overboard piping.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2019 Resolved
Seven (07) waterlight batteries were expired. VSL must provide serviceable waterlight batteries for all 07 waterlights.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2019
Resolution: VSL has replaced all waterlights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019 Resolved
Retention clips for high voltage cabling on SSDG is missing rubber chaffe gear, cutting into cable insulation. VSL must provide adequate chaffing gear for high voltage cabling.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2019
Resolution: VSL installed new retention clips for high voltage wiring.
Stability › Watertight Integrity › General
Issued 15 September 2010 Resolved
Vessel has 8' x 22' sideshell in need of repair from collision. Vessel is allowed to transit to repair facility and call MSU Houma prior to starting any repairs. Extra precautions were placed on vessel during transit.
Action required: 705 - Other - as specified
Resolved 23 September 2010
Resolution: All repairs maded satisfactory.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 July 2008 Resolved
Replace broken mounting bracket
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2008
Resolution: New mounting bracket installed
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 July 2008 Resolved
Update numbers on EAP placard
Due 30 July 2008
Resolved 24 July 2008
Resolution: EAP placard was updated with new numbers.

Casualty record · 2

15 September 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3941430
11 May 2026Routine · role: Involved in a Marine Casualty · activity 8373077
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.