Records from 2016 to 2026. Most recent: inspection, 6 August 2026.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2025
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Observed a battery containment box was loose. Secure battery box to prevent movement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2026
Resolved 27 January 2026
Resolution: Provided satisfactory video of battery box being secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2025
Resolved
All electrical equipment and circuits must be clearly marked and identified. Observed breaker switches without labeling. Provide labeling to indicate connection source.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 6 February 2026
Resolution: Received satisfactory pictures of labeling of the breaker switches.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2024
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection.
Fire extinguisher at operating station was not stowed in a bracket approved by the fire extinguisher manufacturer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: Correct bracket was installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency.
One of three fire buckets was cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: Another fire bucket was put onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 June 2024
Resolved
A durable placard must be posted next to all
radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
The emergency broadcast placard was faded and unreadable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: A placard was placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
No lifejacket donning placard was posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: A placard was placed on the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 June 2024
Resolved
Electrical equipment exposed to the weather must be watertight.
Electrical equipment exposed to corrosive environments must be of suitable construction and corrosion-resistant.
Extension cord was run from generator on aft deck, through an aft window, and along the port side, under the seats, to the port forward area inside the cabin. Extension cords cannot be used as permanent wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: Extension cord was removed.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 28 June 2024
Resolved
Seats must be constructed to minimize possibility of injury and avoid trapping occupants.
The starboard aft seat in the center row of seating was not attached to the deck. Open from previous inspection
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: Seat was fastened to the deck.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 June 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) US COAST PILOT or similar publication (2) Coast guard Light list (3) Tide Tables, and (4)Current tables
Vessel did not have up-to-date Light List on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: Updated light list was put on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 June 2024
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these rules.
Vessel did not have copy of Inland Navigation rules on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: New Nav Rules book was placed on vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 June 2024
Resolved
Vessel must carry either first aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
First aid kit on board contained several expired products. Open from previous inspection
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2024
Resolved 29 July 2024
Resolution: A new first aid kit was placed on the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 May 2024
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date.
Vessel missed the annual inspection window of 3 months before or after the anniversary date of 07FEB23 rendering its COI invalid. Vessel is required to complete a COI inspection prior to recertification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: All requirements have been met to re-obtain COI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 February 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Found 03 orange hand and 01 red distress signals to be expired.
46 CFR 180.68 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2023
Resolution: Verified new distress flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Current battery to floating waterlight was found expired.
46 CFR 180.70 (d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2023
Resolution: Verified operation of waterlight, and installation of new battery.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 February 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Expired items in kit.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2023
Resolved 29 July 2024
Resolution: New first aid kit was placed on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2023
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire-extinguisher bracket not mounted securely.
46 CFR 181.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2023
Resolution: Verified repair made to fire exingutisher bracket.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 February 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions not posted on vessel.
46 CFR 185.510 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2023
Resolution: Verified proper emergency instructions posted at operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts. Found dead-ended wires, hanging speed gauge, and lightening fixture with no cover in head.
46 CFR 183.200 (b)(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2023
Resolution: Verified all dead end and loose wires have been removed or secured properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2023
Resolved
Electrical equipment exposed to corrosive environments must be of suitable construction and corrosion-resistant. Batteries on aft deck did not have covers to prevent corrosion to terminals.
46 CFR 183.210 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2023
Resolution: Battery covers were replaced satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 February 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Marking was not adequately visible.
46 CFR 185.608
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2023
Resolution: Verified new placard for fuel shutoffs.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 6 February 2023
Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Seats were not securely mounted to deck.
46 CFR 177.820 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2023
Resolved 29 July 2024
Resolution: Seat was secured to the deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 January 2023
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Cracked starboard window and some not able to fully open or close.
46 CFR 177.1020
Action required: 10 - Deficiency Rectified
Resolved 29 July 2024
Resolution: Windows have been temporarily repaired to satisfaction of [name withheld] repairs will be addressed during upcoming drydock.
29JUL24: Windows are sufficient for route and conditions.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 August 2021
Resolved
OPERATOR SHALL BE PREPARED TO TEST THE STEERING SYSTEMS OF THE VESSEL FOR FIT FOR SERVICE. STEERING SYSTEM INOPERABLE. REPAIR STEERING SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2021
Resolution: Observed a satisfactory repair and testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2020
Resolved
A vessel must carry one floating waterlight, must be approved IAW 46 CFR 161.010 in Subchapter Q. Replace broken water light holder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 3 June 2020
Resolution: Water light mount replaced.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 19 May 2020
Resolved
Two required means of escape must be widely separated and at opposite ends. Fix foward dooor handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 3 June 2020
Resolution: Door handle repaired.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 May 2020
Resolved
A vessel must be fitted with gound tackle for the vessel to be safely anchored or moored. Installed mousing wire to shackle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 3 June 2020
Resolution: Mousing wire installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 September 2019
Resolved
A vessel of at least 5 net tons engaged in coastwise trade must have a valid certificate of documentation. No COD was onboard. Provide proof of COD.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
Resolution: Vessel rep provided proof of valid COD onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2019
Resolved
A vessel not required to have a fire pump must have three fire buckets. Repair/Replace fire buckets and handles.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
Resolution: Vessel rep provided photo of 3 new fire buckets onboard.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 September 2019
Resolved
Portable fire extinguishers must be clearly visible and readily accessible. The port forward extinguisher is blocked by a table and cooler. Remove obstructions.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2019
Resolution: Vessel rep provided photo of accessible extinguisher.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 10 September 2019
Resolved
A vessel must have a marine sanitation device that complies with 33 CFR Part 159. The vessel's toilet was removed. Vessel is restricted to voyages of not more than 30 minutes away from the dock until the toilet is properly installed.
Action required: 705 - Other - as specified
Resolved 7 November 2019
Resolution: Vessel's toilet has been reinstalled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 September 2019
Resolved
Electrical equipment shall be maintained to provide necessary services. The wiring sleeve into the starboard outboard motor has come off. Reinstall wiring sleeve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 7 October 2019
Resolution: Wiring sleeve has been properly reinstalled.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 September 2019
Resolved
Each vessel must have at least 2 portable battery lights. Only one light was onboard. Provide another light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 7 October 2019
Resolution: 2 flashlights in packaging were provided.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 September 2019
Resolved
Life jacket donning placards must be posted in conspicuous places that are places that are regularly accessible and visible. The donning placard is obstructed by the life ring buoy. Relocate the donning placard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 7 October 2019
Resolution: Donning placard has been moved to the aft bulkhead in a visible location.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 September 2019
Resolved
The master and crew must be familiar with the content of the emergency instructions. The crew's actions did not match the man overboard instructions. Revise the instructions to reflect actual crew actions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 7 October 2019
Resolution: Emergency instructions have been revised.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 September 2019
Resolved
Crew training shall be documented for review by the coast guard upon request. Logs are kept electronically. Provide a copy of ship's logs for review.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2019
Resolved 7 October 2019
Resolution: A print-out of the company's vessel logs was provided for review.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 10 September 2019
Resolved
The fuel tanks must be adequately supported and braced. The starboard fuel tank aft supports are fractured. Provide a repair proposal to fix the broken tank supports.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2019
Resolved 7 November 2019
Resolution: Fuel tank mount has been reinforced with additional aluminum flat bar.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 10 September 2019
Resolved
Seats must be constructed to minimize the possibility of injury. 7 of the centerline bench seats have broken/dilapidated seats. Repair/replace seat benches.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2019
Resolved 7 November 2019
Resolution: All broken seat benches have been repaired/replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 10 September 2019
Resolved
Seats used to determine passenger count must be secured to the deck or bulkhead. None of the interior seats are secured. One of the bow seats is unsecured. Permanently mount all seats to the deck and/or bulkhead no later than 09 November 2019.
Action required: 705 - Other - as specified
Due 9 November 2019
Resolved 7 November 2019
Resolution: All seating permanently mounted to the deck with screws.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 August 2018
Resolved
CLSN: Vsl is broadcasting Invalid Call Sign, AIS PLACEMENT NOT PROVIDED: incomplete dimension information (AIS Antenna Position “X” equals 0)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2018
Resolved
Flexible hose must have a high resistance to saltwater, petroleum oils, and vibration. Both hydraulic hoses at outboards found cracked/worn.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 14 August 2018
Resolution: Hydraulic hoses were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2018
Resolved
Electrical equipment must be installed and maintained to: protect passengers, crew, other persons and the vessel from electrical hazards. Multiple dead-end wires were found under operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 14 August 2018
Resolution: Dead-end wires were removed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 July 2018
Resolved
Vessel name must be marked on clearly visible exterior part of the bow. Vessel name is not marked on bow.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 14 August 2018
Resolution: Vessel name is marked on bow.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 August 2017
Resolved
No alcohol test strips onboard
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 28 August 2017
Resolution: Alcohol test strips have been placed onboard
Communications › Visual Communication › Signalling Lamp
Issued 28 August 2017
Resolved
Anchor light inoperative
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 28 August 2017
Resolution: Anchor light bulb was replaced, light is now operative
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 28 August 2017
Resolved
EAP poster not posted
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 29 August 2017
Resolution: EAP statement has been appropriately posted.
Fire Fighting › Fire Bucket › Lanyard
Issued 28 August 2017
Resolved
Fire buckets are missing lanyards
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 28 August 2017
Resolution: Lanyards have been properly attached to all fire buckets
Communications › Audible Communications › Bell
Issued 28 August 2017
Resolved
Ship's bell is missing lanyard
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 28 August 2017
Resolution: Lanyard has been attached to the ship's bell
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 September 2016
Resolved
Vessel's COD is expired. COD must be renewed and placed on board vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2016
Resolved 8 September 2016
Resolution: COD has been processed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 September 2016
Resolved
Vessel's 04 portable fire extinguishers have not been serviced. All fire extinguishers must be serviced by approved organization.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2016
Resolved 8 September 2016
Resolution: Extinguishers have been serviced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 September 2016
Resolved
One of the windows on the starboard side of the vessel was busted during the recent Hurricane. Remove all debris and fix window.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 16 September 2016
Resolution: Window was replaced.