MAURY USCG vessel records
← All vessels

405

405 is a 2007 tank barge. The Coast Guard has recorded 25 inspections since 2007, most recently in March 2026, along with 10 deficiencies.

Records from 2007 to 2026. Most recent: inspection, 10 March 2026.

Built
2007
Last inspected
10 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2007–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

876869
Flag
UNITED STATES
Maury page id
psix-876869

Documentation record

Registered dimensions (L × B × D)263.3 ft × 54.0 ft × 15.0 ft
Registered tonnagegross 2,113 / net 2,113
ITC dimensions (L × B × D)263.3 ft × 54.0 ft × 15.0 ft
ITC tonnagegross 1,735 / net 993
BuilderSOUTHWEST SHIPYARD · HOUSTON, TX, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 March 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1735 - Convention (Subpart B), Gross Ton
2113 - Regulatory (Subpart C or D), Gross Ton
993 - Convention (Subpart B), Net Ton
2113 - Regulatory (Subpart C or D), Net Ton
85985 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

25 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 1 vessel inspected with it, by name and date; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MIAMI Towing Vessel · MISLE 202209 · 8 November 2014 · activity 5040313

Inspection history · 25

10 March 2026 Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8326815
28 October 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8260735
28 October 2024 Periodic Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8018059
17 October 2023 MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7810118
24 October 2022 Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7582595
17 August 2021 Examination of Repairs · Internal Structural Exam · COI Inspection · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7278850
28 July 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7019922
27 April 2019 Periodic Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6671529
6 August 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6506907
11 July 2017 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6219087
20 June 2016 Deficiency Check · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5914031
7 July 2015 Deficiency Check · MTSA Verification · Periodic Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5176320
8 November 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5040313
5 May 2014 Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4849028
6 August 2013 MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4675860
2 July 2013 Examination of Repairs · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4641011
30 May 2012 COI Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4335060
14 May 2010 Internal Structural Exam · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3737871
14 July 2009 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3534311
29 May 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3492551
17 June 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3239441
25 February 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3152966
27 August 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3039977
21 July 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3020354
17 May 2007 Cargo Tank Internal · Initial Certification · Internal Structural Exam · Hull Examination · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2901732

Deficiency record · 10

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2023 Resolved
Each cargo tank of a tank barge must have a high-level indicating device, unless the barge complies with 46 CFR 39.2009(a). The high level and overfill alarms did not function as designed. Renew alarm systems and perform testing to the satisfaction of the attending marine inspector. 46 CFR 39.2003(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2023
Resolved 8 November 2023
Resolution: Witnessed alarm panel and high level and overfill alarms, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2022 Resolved
46 CFR 54.01-35 (b)(1): The pressure portions of pressure vessels hsall: Normally have a corrosion allowance of one -sixth or the calculated thickness as determined by thed applicable design formula. Start air compressor has excessive pitting surrounding the data plate, submit measuremnt calculations on shell and pitting to ensure the corrosion is in allowance.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2022
Resolved 8 December 2022
Resolution: Data plate re-welded on air compressor, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 24 October 2022 Resolved
46 CFR 32.15-15 (e): All components of the system must be in general conformity with the standards issued. Towing chains have excessive wear, steel has rusted away and chain links need measurements for acceptability. Send report with measurements within ABS standards or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2022
Resolved 8 December 2022
Resolution: Chain replaced, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 October 2022 Resolved
46 CFR 38.10-20: Each tank shall be fitted with a liquid level gagind device of approved design to indicate the maximum level to which the tank may be filled with liquid. Secondary alarm lights at Cargo tanks were not lighting when testing hi-level alarms. Replace lights to the satisfaction of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2022
Resolved 8 December 2022
Resolution: Alarm light gaging panel replaced,
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (air motor)
Issued 19 July 2016 Resolved
Prove proper operation of starboard pump engine and demostrate operation of emergency shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2016
Resolution: O/O installed new air starter. Pump engine started and ran then properly shutdown via emergency pull cable.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 7 July 2015 Resolved
Outer insulating cover of cable for forward deck work lights is damaged, exposing inner insulation. Operator required to repair or remove from service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2015
Resolution: Verified wiring has been renewed, sealant placed around cover in various locations to provide weather tight integrity.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 7 July 2015 Resolved
Low pressure lift pump is leaking at diaphragm. Operator states will renew pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2015
Resolution: Verified leak free operation of renewed pump by op test to coincide with satisfactory e-stop check.
Engineering › Pressure Vessel › Coast Guard Symbol
Issued 6 August 2013 Resolved
Proved evidence that pressure vessel has adequate corrosion allowance.
Due 27 September 2013
Resolved 7 July 2015
Resolution: Presure vessel label has UL stamp from ASME demonstrating satisfactory complience.
Construction/Loadline › Hull › Hull Plating
Issued 2 July 2013 Resolved
Permanent repairs of port side aft outer shell plating to be completed at next scheduled drydock.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 29 April 2019
Resolution: Issued rectified in previous dry dock availability. Verified no temp repairs reamined durin the ISE.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 17 May 2007 Resolved
Provide documentation showing that electrical connections on engine meets Class 1 Div 1, by 31Aug07.
Due 1 August 2008
Resolved 25 February 2008
Resolution: In lieu of meeting Class I/ Division 1 requirements, vessel is limited to the carriage of combustible Grade "D" cargoes having a flashpoint of 140 degrees Fahrenheit or above in accordance with D8(dp) Policy Letter 02-2007 Change 1.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.