MAURY USCG vessel records
← All vessels

LNG ALLIANCE

LNG ALLIANCE is a 2007 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in September 2023, along with 24 deficiencies and 1 operational control.

Records from 2016 to 2023. Most recent: inspection, 28 September 2023.

Built
2007
Last inspected
28 September 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 September 2023
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9320075
876974
Flag
FRANCE
Maury page id
psix-876974

Documentation record

Tonnage as PSIX records it29322 - Convention (Subpart B), Net Ton
117388 - Displacement, Metric Ton
86389 - Dead Weight, Metric Ton
97741 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

28 September 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7799798
3 June 2023 PSC B · Deficiency Check · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7695545
24 March 2021 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7155795
11 February 2021 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7139488
6 March 2020 COC-GAS Renew · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6917624
5 January 2019 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6605882
2 July 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6463742
28 January 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6344867
22 January 2018 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6341262
26 November 2017 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6310385
9 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6303923
17 January 2017 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6071774
24 December 2016 Special · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6062102
13 December 2016 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6056937
4 November 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036607
1 November 2016 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6032984
11 October 2016 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6020053
26 August 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5986382
25 August 2016 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5983227
22 July 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Renew · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5949105

Deficiency record · 24

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 June 2023 Resolved
"NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE ABLE TO COLLECT INCLUDING THOSE ON BOARD TANKERS OR IN COMPARTMENTS ASSIGNED PRINCIPALLY TO ACCUMLATOR BATTEREIES, IN PAINT LOCKERS, ACETYLENE, STORES, OR SIMILAR SPACES." PSCO OBSERVED MULTIPULE CRACKED EXPLOSION PROOF LIGHTS INCLUDING: ONE IN THE COMPRESSOR ROOM, ONE ABOVE #4 LIQUID DOME ,ONE ABOVE #2 VAPOR DOME AND 2 IN THE OXIDIZER ROOM. 74 SOLAS (2004) II-1/45.10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 June 2023
Resolution: PSCO verified replacement of the light fixture lenses.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 June 2023 Resolved
"AN AIRLOCK SHOULD ONLY BE PERMITTED BETWEEN A GAS-DANGEROUS ZONE ON THE OPEN WEATHER DECK AND A GAS-SAFE SPACE AND SHOULD CONSIST OF TWO STEEL DOORS SUBSTANTIALLY GAS TIGHT SPACE." PSCO OBSERVED SIGNIFICANT GAPS BETWEEN THE KNIFE EDGE AND GASKET MATERIAL OF THE EXTERIOR AIRLOCK DOOR AND PORTION OF THE DOOR LATCH MISSING FROM THE INTERIOR DOOR RENDERING NEITHER DOOR SUBSTANTIALLY GAS TIGHT. 74 SOLAS (2020) VII/13.1 IGC 93 3.6.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2023
Resolved 30 June 2023
Resolution: Service report provided stating "Gasket fully replaced, handles adjusted. Tightness checked by hose test." Pictures were provided of the repair.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 June 2023 Resolved
"ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION." WHILE STEERING PUMPS WERE PARALLELED AND THE GEAR PLACED HARD OVER TO EITHER SIDE, THE PUMPS WOULD ERRATICALLY JUMP BETWEEN 30 DEGREES TO 35 DEGREES UNABLE TO HOLD A CONSISTENT RUDDER ANGLE. 74 SOLAS (2004) II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2023
Resolved 13 July 2023
Resolution: Vessel provided Class Report attesting to repairs made to their steering pumps.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2023 Resolved
"DOOR FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY 'A' SHALL BE REASONABLY GAS TIGHT AND SELF-CLOSING." MULTIPLE FIRE DOORS IN THE ENGINE ROOM WERE MISSING A PORTION OF THE DOOR LATCH. 74 SOLAS (2004) II-2/9.4.2.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2023
Resolved 30 June 2023
Resolution: Service report provided stating "All engine room doors are regularly checked and adjusted for automatic closing,door latch mentioned in deficiency were inadvertently omitted. Spare latches stored in safety lockers."Pictures provided. were replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 June 2023 Resolved
"AN AUDIBLE AND VISUAL ALARM SYSTEM TO GIVE A WARNING ON BOTH SIDES OF THE AIRLOCK" THE INTERIOR AIRLOCK VISUAL INDICATOR WAS EXTINGUISHED. 74 SOLAS (2020) VII/13.1 IGC 93 3.6.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 June 2023
Resolution: [name withheld] OF EXTINGUISED LIGHT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 June 2023 Resolved
"WHERE A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM IS REQUIRED FOR PROTECTION OF SPACES... AT LEAST ONE DETECTOR COMPLYING WITH THE FIRE SAFETY SYSTEM CODE SHALL BE INSTALLED IN EACH SUCH SPACE." THE FLAME DETECTOR PROTECTION THE INCINERATOR ROOM WAS NONFUNCTIONAL. THE CREW REPLACED WITH A SPARE AND TESTED STATISFACTORILY. 74 SOLAS (2004) II-2/7.2.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 June 2023
Resolution: THE CREW REPLACED WITH A SPARE AND TESTED SATISFACTORILY
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2023 Resolved
"MACHINERY SPACE OF CAT. A CONTAINING OIL FUEL UNITS SHALL BE PROVIDED WITH ANY ONE OF THE FIXED FIRE- EXTINGUISHING SYSTEMS." THE FLEXIBLE HOSE ON MULTIPLE HI-FOG N2 BOTTLES ARE DRY-ROTTING AND CRACKING. 74 SOLAS (2004) II-2/10.5.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2023
Resolved 13 July 2023
Resolution: Vessel provided Class Report attesting to repairs made to the CO2 hoses.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 January 2019 Resolved
04110 - Each lifeboat shall be launched, and maneuvered in the water by its assigned operating crew, at least once every three months during an abandon ship drill. The lifeboats have not been launched and maneuvered in the water since 18SEP18. SOLAS 74 (2014 Cons) III/19.3.3.3
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2020
Resolution: Drill records reviewed with satisfactory results.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 January 2019 Resolved
11102 - Every lifeboat shall consist of food rations totaling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate and these rations shall be kept in air tight packaging. Port and STBD lifeboats were supplied with 45 food rations and the lifeboats accommodate 50 persons. Also, 23 food rations were found with failed air tight packaging. SOLAS 74 (2014 Cons.) III/31.1.1 LSA Code 4.4.8.12
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 9 March 2020
Resolution: Lifeboat ood rations examined with satisfactory results.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 5 January 2019 Resolved
12199 - An airlock should consist of two steel doors substantially gastight. The gastight gasket on the airlock failed. PSCO observed sunlight coming through the door. SOLAS 74 (2014 Cons.) VI/13.1 IGC Code 3.6
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 March 2020
Resolution: The crew replaced the worn gasket.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 5 January 2019 Resolved
12199 - On ships carrying toxic or flammable cargoes, or both, a water spray system for cooling, fire prevention, and crew protection should be installed to cover exposed cargo tank domes and any exposed parts of the cargo tanks. 02 spray nozzles on the C.T. #2 gas dome were clogged. SOLAS 74 (2014 Cons.) VI/31.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 March 2020
Resolution: The crew unclogged the nozzles.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform w/ the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Rudder stbd side inspection cover missing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 July 2018
Resolution: The vessel provided documentation attesting to the rectification of the missing cover plate on the rudder.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 18 January 2017 Resolved
Vessel's gas indicator for the #3 primary barrier space did not indicate the correct percentage of span gas introduced into the space. The read value on cubicle screen should be the same as the span gas bottle concentration value +/- 2%.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 19 January 2017
Resolution: Received class report attesting to the gas detection system.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 January 2017 Resolved
2515 - The company should identify equipment and technical systems, the sudden operational failure of which may result in hazardous situations. The company's SMS for control of gas equipment does not address the fixed gas detection system for interbarrier spaces.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 November 2017
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 3 January 2017 Resolved
1410 - Under all sailing conditions, including maneuvering, the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable form the navigation bridge. Vessel lost pilothouse propulsion control while preparing to get underway. 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2017
Resolved 4 January 2017
Resolution: Vessel submitted class survey report stating that the faulted item had been isolated and satisfactory tests of the propulsion were conducted.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 7 November 2016 Resolved
See attached form B
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 21 April 2017
Resolution: Received email and class report attesting to the installation of an additional gas detector. This corrective action fulfills the SMS recommendation from the near miss report from 2007.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 2 November 2016 Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column F in the table of chapter 19. Gas detector for the HVAC room was found inoperable. No fault was detected on the alarm panel in CCR.40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 December 2016
Resolved 4 November 2016
Resolution: Tested detector. SAT.
Construction/Loadline › Structures › Ventilators
Issued 25 August 2016 Resolved
*See attached Form B. Inefficient space for the deficiency description.
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 4 November 2016
Resolution: Temporary hose has been removed to the satisfaction of attending MI and attending class surveyor.
Engineering › Fuel Oil Service System › Valve
Issued 27 July 2016 Resolved
1899 - A master gas fuel valve that can be closed from the machinery space should be provided within the cargo area. The valve should be arranged so as to close automatically if leakage of gas is detected. When gas detection in the machinery space was tested the master gas valve failed to close.
Action required: 705 - Other - as specified
Resolved 27 July 2016
Resolution: Vessel's crew repaired valve and operationally tested.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 27 July 2016 Resolved
1850-On ships carrying flammable products, a water spray system for cooling, fire protection and crew protection should be installed to cover exposed cargo tank domes and any exposed parts of cargo tanks. 1 spray head is missing on the #1 liquid dome, all spray heads on the #2 gas dome clogged, 1 spray heads clogged on the #3 gas dome, and 1 spray head clogged on the stbd manifold aft liquid line.
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 29 July 2016
Resolution: Vessel's crew replaced missing nozzle and flushed system. Operationally tested all spray nozzles.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 27 July 2016 Resolved
1850-On ships carrying flammable products, a water spray system for cooling, fire protection and crew protection should be installed to cover boundaries of superstructures and deck houses. The cargo area riser stbd side between the 4th and 5th water spray pipes is wasted and holed in 3 locations. IGC Code 11.3.1.4
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 29 July 2016
Resolution: Vessel's crew made temporary repairs by replacing wasted pipe with new and installing rubber tensioning pipe bands at connection points. Operationally tested temporary piping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 July 2016 Resolved
1730 - The condition of the ship and it's equipment shall be maintained to conform to the provisions of the present convention. Inlet piping from bilge tank to the OWS was found wasted with a rubber patch.
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: Vessel's crew temporarily removed piping and welded wasted area. Operationally tested welded inlet piping.
Engineering › Fuel Oil Service System › Ventilation
Issued 27 July 2016 Resolved
1899-The vent hood or casing should be installed or mounted to permit the ventilating air to sweep across the gas utilization unit and be exhausted at the top of the vent hood or casing. Port and stbd gas valve rooms have temporary hoses redirecting the flow of ventilation, see 2007 Gazocean feedback report 00507 in vessel documents.
Action required: 705 - Other - as specified
Due 1 August 2017
Resolved 25 August 2016
Resolution: Vessel provided email from RO that the GVU room has not been modified according to IGC code.
Electrical › Electric Supply System (service) › Cable
Issued 27 July 2016 Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. A bonding cable on the #2 LD compressor motor was found detatched and fitting was missing from the #2 HD compressor motor junction box.
Action required: 705 - Other - as specified
Resolved 27 July 2016
Resolution: Vessel's crew attached bonding cable to motor casing and installed a threaded bolt into the open hole of the junction box.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.