← All vessels
LNG ALLIANCE
LNG ALLIANCE is a 2007 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in September 2023, along with 24 deficiencies and 1 operational control.
Records from 2016 to 2023. Most recent: inspection, 28 September 2023.
- Built
- 2007
- Last inspected
- 28 September 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9320075 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
FMLU
876974
Flag
FRANCE
—
Maury page id
psix-876974
Inspections, by type
…with no type recorded2
Years with a record
7 calendar years (2016–2023)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29322 - Convention (Subpart B), Net Ton
117388 - Displacement, Metric Ton
86389 - Dead Weight, Metric Ton
97741 - Convention (Subpart B), Gross Ton
117388 - Displacement, Metric Ton
86389 - Dead Weight, Metric Ton
97741 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
28 September 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7799798
3 June 2023
PSC B · Deficiency Check · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7695545
24 March 2021
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7155795
11 February 2021
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7139488
6 March 2020
COC-GAS Renew · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6917624
5 January 2019
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6605882
2 July 2018
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6463742
28 January 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6344867
22 January 2018
Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6341262
26 November 2017
Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6310385
9 November 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6303923
17 January 2017
Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6071774
24 December 2016
Special · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6062102
13 December 2016
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6056937
4 November 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6036607
1 November 2016
Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6032984
11 October 2016
Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6020053
26 August 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5986382
25 August 2016
Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5983227
22 July 2016
Ballast Water Examination · ISPS II Exam · COC-GAS Renew · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5949105
Deficiency record · 24
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 June 2023
Resolved
"NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE ABLE TO COLLECT INCLUDING THOSE ON BOARD TANKERS OR IN COMPARTMENTS ASSIGNED PRINCIPALLY TO ACCUMLATOR BATTEREIES, IN PAINT LOCKERS, ACETYLENE, STORES, OR SIMILAR SPACES." PSCO OBSERVED MULTIPULE CRACKED EXPLOSION PROOF LIGHTS INCLUDING: ONE IN THE COMPRESSOR ROOM, ONE ABOVE #4 LIQUID DOME ,ONE ABOVE #2 VAPOR DOME AND 2 IN THE OXIDIZER ROOM.
74 SOLAS (2004) II-1/45.10
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 June 2023
Resolved
"AN AIRLOCK SHOULD ONLY BE PERMITTED BETWEEN A GAS-DANGEROUS ZONE ON THE OPEN WEATHER DECK AND A GAS-SAFE SPACE AND SHOULD CONSIST OF TWO STEEL DOORS SUBSTANTIALLY GAS TIGHT SPACE." PSCO OBSERVED SIGNIFICANT GAPS BETWEEN THE KNIFE EDGE AND GASKET MATERIAL OF THE EXTERIOR AIRLOCK DOOR AND PORTION OF THE DOOR LATCH MISSING FROM THE INTERIOR DOOR RENDERING NEITHER DOOR SUBSTANTIALLY GAS TIGHT.
74 SOLAS (2020) VII/13.1
IGC 93 3.6.1
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 June 2023
Resolved
"ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION." WHILE STEERING PUMPS WERE PARALLELED AND THE GEAR PLACED HARD OVER TO EITHER SIDE, THE PUMPS WOULD ERRATICALLY JUMP BETWEEN 30 DEGREES TO 35 DEGREES UNABLE TO HOLD A CONSISTENT RUDDER ANGLE.
74 SOLAS (2004) II-1/29.2.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2023
Resolved
"DOOR FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY 'A' SHALL BE REASONABLY GAS TIGHT AND SELF-CLOSING." MULTIPLE FIRE DOORS IN THE ENGINE ROOM WERE MISSING A PORTION OF THE DOOR LATCH.
74 SOLAS (2004) II-2/9.4.2.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 June 2023
Resolved
"AN AUDIBLE AND VISUAL ALARM SYSTEM TO GIVE A WARNING ON BOTH SIDES OF THE AIRLOCK" THE INTERIOR AIRLOCK VISUAL INDICATOR WAS EXTINGUISHED.
74 SOLAS (2020) VII/13.1
IGC 93 3.6.3
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 June 2023
Resolved
"WHERE A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM IS REQUIRED FOR PROTECTION OF SPACES... AT LEAST ONE DETECTOR COMPLYING WITH THE FIRE SAFETY SYSTEM CODE SHALL BE INSTALLED IN EACH SUCH SPACE." THE FLAME DETECTOR PROTECTION THE INCINERATOR ROOM WAS NONFUNCTIONAL. THE CREW REPLACED WITH A SPARE AND TESTED STATISFACTORILY.
74 SOLAS (2004) II-2/7.2.3
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2023
Resolved
"MACHINERY SPACE OF CAT. A CONTAINING OIL FUEL UNITS SHALL BE PROVIDED WITH ANY ONE OF THE FIXED FIRE- EXTINGUISHING SYSTEMS." THE FLEXIBLE HOSE ON MULTIPLE HI-FOG N2 BOTTLES ARE DRY-ROTTING AND CRACKING.
74 SOLAS (2004) II-2/10.5.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 January 2019
Resolved
04110 - Each lifeboat shall be launched, and maneuvered in the water by its assigned operating crew, at least once every three months during an abandon ship drill. The lifeboats have not been launched and maneuvered in the water since 18SEP18.
SOLAS 74 (2014 Cons) III/19.3.3.3
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 January 2019
Resolved
11102 - Every lifeboat shall consist of food rations totaling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate and these rations shall be kept in air tight packaging. Port and STBD lifeboats were supplied with 45 food rations and the lifeboats accommodate 50 persons. Also, 23 food rations were found with failed air tight packaging.
SOLAS 74 (2014 Cons.) III/31.1.1
LSA Code 4.4.8.12
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 5 January 2019
Resolved
12199 - An airlock should consist of two steel doors substantially gastight. The gastight gasket on the airlock failed. PSCO observed sunlight coming through the door.
SOLAS 74 (2014 Cons.) VI/13.1
IGC Code 3.6
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 5 January 2019
Resolved
12199 - On ships carrying toxic or flammable cargoes, or both, a water spray system for cooling, fire prevention, and crew protection should be installed to cover exposed cargo tank domes and any exposed parts of the cargo tanks. 02 spray nozzles on the C.T. #2 gas dome were clogged.
SOLAS 74 (2014 Cons.) VI/31.1
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform w/ the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Rudder stbd side inspection cover missing.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 18 January 2017
Resolved
Vessel's gas indicator for the #3 primary barrier space did not indicate the correct percentage of span gas introduced into the space. The read value on cubicle screen should be the same as the span gas bottle concentration value +/- 2%.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 January 2017
Resolved
2515 - The company should identify equipment and technical systems, the sudden operational failure of which may result in hazardous situations. The company's SMS for control of gas equipment does not address the fixed gas detection system for interbarrier spaces.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 3 January 2017
Resolved
1410 - Under all sailing conditions, including maneuvering, the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable form the navigation bridge. Vessel lost pilothouse propulsion control while preparing to get underway. 17a
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 7 November 2016
Resolved
See attached form B
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 2 November 2016
Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column F in the table of chapter 19. Gas detector for the HVAC room was found inoperable. No fault was detected on the alarm panel in CCR.40ac
Construction/Loadline › Structures › Ventilators
Issued 25 August 2016
Resolved
*See attached Form B. Inefficient space for the deficiency description.
Engineering › Fuel Oil Service System › Valve
Issued 27 July 2016
Resolved
1899 - A master gas fuel valve that can be closed from the machinery space should be provided within the cargo area. The valve should be arranged so as to close automatically if leakage of gas is detected. When gas detection in the machinery space was tested the master gas valve failed to close.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 27 July 2016
Resolved
1850-On ships carrying flammable products, a water spray system for cooling, fire protection and crew protection should be installed to cover exposed cargo tank domes and any exposed parts of cargo tanks. 1 spray head is missing on the #1 liquid dome, all spray heads on the #2 gas dome clogged, 1 spray heads clogged on the #3 gas dome, and 1 spray head clogged on the stbd manifold aft liquid line.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 27 July 2016
Resolved
1850-On ships carrying flammable products, a water spray system for cooling, fire protection and crew protection should be installed to cover boundaries of superstructures and deck houses. The cargo area riser stbd side between the 4th and 5th water spray pipes is wasted and holed in 3 locations. IGC Code 11.3.1.4
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 July 2016
Resolved
1730 - The condition of the ship and it's equipment shall be maintained to conform to the provisions of the present convention. Inlet piping from bilge tank to the OWS was found wasted with a rubber patch.
Engineering › Fuel Oil Service System › Ventilation
Issued 27 July 2016
Resolved
1899-The vent hood or casing should be installed or mounted to permit the ventilating air to sweep across the gas utilization unit and be exhausted at the top of the vent hood or casing. Port and stbd gas valve rooms have temporary hoses redirecting the flow of ventilation, see 2007 Gazocean feedback report 00507 in vessel documents.
Electrical › Electric Supply System (service) › Cable
Issued 27 July 2016
Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. A bonding cable on the #2 LD compressor motor was found detatched and fitting was missing from the #2 HD compressor motor junction box.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.