Records from 2008 to 2009. Most recent: inspection, 27 July 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 15 January 2009
Resolved
Prove minimum safe manning prior to departing port Hampton Roads.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2009
Resolution: Proved safe manning as required to the satisfaction of attending Coast Guard Marine Inspector.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 15 January 2009
Resolved
STBD Generator has a exhaust leak, Repair/replace coupling that is causing the leak.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2009
Resolution: Repaired to the satisfaction of attending Coast Guard Marine Inspector.
Operations/Management › Drug and Alcohol Testing › DHHS Certified Laboratory
Issued 9 April 2008
Resolved
This company has contract with a Certified Laboratory, only uses sample confirmation for all screened non-negatives done on site. This procedure does not fall under the guidlines of Department of Transportation/USCG.
Due 21 April 2008
Resolved 19 June 2008
Resolution: Company started completing discrepencies 04/09/2008, kept in contact with Sector and District DAPI the status and update of their program. Company now enrolled and using Nowcare Collection Facilities.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 April 2008
Resolved
Company could not produce any EAP records.
Due 21 April 2008
Resolved 19 June 2008
Resolution: Members have been educated on chemical testing causes and effects of the substance and responsibility of owner.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 April 2008
Resolved
No proof of training
Due 21 April 2008
Resolved 19 June 2008
Resolution: Mariners Trained.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 9 April 2008
Resolved
Company has yet to submit an Management Informtion Systems (MIS) report .
Due 21 April 2008
Resolved 30 June 2008
Resolution: Received MIS report
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 9 April 2008
Resolved
No proof of Pre-employment drug testing or background checks.
Due 21 April 2008
Resolved 19 June 2008
Resolution: Future employees will be pre-employment and background tested.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 31 March 2008
Resolved
Provide proof of GMDSS endorsements for all licensed deck officers.
Due 30 April 2008
Resolved 18 April 2008
Resolution: Provided proof of endorsements
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 31 March 2008
Resolved
Provide proof of GMDSS shore side maintenance program
Due 30 April 2008
Resolved 30 April 2008
Resolution: Proof provided of GMDSS shore side maintenance program.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 March 2008
Resolved
Provide proof of drug testing program for crewmembers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2008
Resolution: Provided proof of all crewmembers enrolled in a testing program.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 31 March 2008
Resolved
Repair steering station to indicate ordered rudder that matches actual rudder angle
Due 30 April 2008
Resolved 18 April 2008
Resolution: Conducted steering test, All sat.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 31 March 2008
Resolved
Remove main engine lube oil alarm bypass switch on main console.
Due 30 April 2008
Resolved 30 April 2008
Resolution: Lube oil alarm bypass switches removed, and main engine lube oil alarms tested from proper operation.
Engineering › Pressure Vessel › Marking and Stamping
Issued 31 March 2008
Resolved
Provide manufacturer's data plate for each pressure vessel.
Due 30 April 2008
Resolved 18 April 2008
Resolution: Inspected dataplates.
Accommodation/Occupational Safety › Potable Water System › General
Issued 31 March 2008
Resolved
Provide cold running water in hospital space.
Due 30 April 2008
Resolved 18 April 2008
Resolution: Inspected sat.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 31 March 2008
Resolved
Provide vital system automation testing procedures iaw 46 cfr 61.40-10 and part 62 to [name withheld] for approval.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 15 July 2008
Resolution: Vital system automation testing procedures submitted and approved.