Records from 2010 to 2026. Most recent: inspection, 20 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 23
20 April 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8352987
8 April 2025
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8108587
5 February 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8075175
19 August 2024
In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7984808
15 April 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7895926
9 June 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7714407
24 April 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7674803
17 January 2023
Hull Examination · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7623509
15 December 2022
Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7609411
9 June 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7476360
5 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7424723
11 May 2021
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7185531
5 February 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7136280
23 June 2020
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7002812
29 April 2019
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6661247
25 March 2019
Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6648905
7 February 2019
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6621582
24 April 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6390393
18 May 2017
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6149571
17 April 2017
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6116992
23 January 2017
Examination of Repairs · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6075060
26 August 2016
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6024880
17 May 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5881975
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 5 April 2022
Resolved
A loading mark required by paragraph (c)(2) of this section must be a horizontal line of at least 205 millimeters (8 inches) in length and 25 millimeters (1 inch) in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint.
Loading marks per stability letter not present.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 4 May 2022
Resolution: Loading marks were properly installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure.
Alternator dead end wire and console wire must be removed or put in enclosure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 4 May 2022
Resolution: Altenator wire was removed and dead end wires in console were put in an enclosure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2022
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
plastic trash can in the head.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 4 May 2022
Resolution: Plastic trash cans removed and replaced with metal.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Anchor light trips the breaker.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 4 May 2022
Resolution: Found a loose connection in the anchor light fixture, replaced connection, which corrected breaker tripping.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 April 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
First aid kit missing some of the required items per 160.041.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 4 May 2022
Resolution: Replaced with approved first aid kit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 April 2022
Resolved
Rails on passenger decks of a vessel engaged in excursion trips, including but not limited to sightseeing trips, dinner and party cruises, and overnight cruises, must be at least 1,000 millimeters (39.5 inches) high.
Tighten aft nets to required heights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 4 May 2022
Resolution: New upper wire was installed and tightened cargo nets to required heights.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 April 2022
Resolved
Each vessel must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls that - (a) Illustrate the purpose of controls; (b) Illustrate the procedures for operating the launching device; (c) Give relevant instructions or warnings; (d) Can be easily seen under emergency lighting conditions; and (e) Display symbols in accordance with IMO Resolution A.760(18).
Launching instructions not present.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 4 May 2022
Resolution: Life raft launching instructions posted on aft hand rail.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 April 2022
Resolved
Lifeboatman. Every person assigned duties as a lifeboatman must hold a credential attesting to such proficiency. Persons serving on vessels subject to the STCW Convention must also hold an STCW endorsement in proficiency in survival craft and rescue boats other than fast rescue boats (PSC).
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 October 2022
Resolved 16 September 2022
Resolution: Mariner completed Survval Craft course RCMMAR-372
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 April 2022
Resolved
hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or other standard specified by the Commandant.
Hydrostatic release was installed incorrectly, held training and corrected.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 April 2022
Resolution: Held training with vessel master and corrected the installation.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 May 2021
Resolved
Batteries installed in lifesaving equipment shall be changed annually. Existing batteries in lifesaving equipment were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2021
Resolved 21 June 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 May 2021
Resolved
CAT I EPIRB required to be equipped with hydro-static release unit (HRU). Existing HRU was out of date/expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 21 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2021
Resolved
Vessel required to be equipped with a first aid kit. Existing first aid kit contained expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 21 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 May 2021
Resolved
Vessel required to carry current/up to date marine charts for areas transited. Existing marine charts were outdated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 21 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 May 2021
Resolved
Watertight hatches are required to be marked. Existing watertight hatches are not marked properly (WATERTIGHT HATCH KEEP CLOSED).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 21 June 2021
Communications › Alarms/Indicators › Fire Alarm
Issued 24 April 2018
Resolved
Vessel had inoperable audible alarm for pre-engineered fire extinguishing system (Fireboy).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 14 May 2018
Resolution: Attending Inspector(s) performed satisfactory operational test of audible alarm.
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 April 2018
Resolved
Vessel was not equipped with current/up to date Coast Pilot.
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 14 May 2018
Resolution: Verified carriage of current/up to date Coast Pilot.
Documentation › Markings/Placards › Warning Signs
Issued 24 April 2018
Resolved
Emergency Instructions not posted/carried on board.
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 14 May 2018
Resolution: Verified proper instalation/posting of emergency escape markings.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 April 2018
Resolved
Vessel's PFD stowage locations are not properly marked with qty.
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 14 May 2018
Resolution: Verified proper markings for PFD storage.
Documentation › Certificates/Documents › Stability Letter
Issued 18 May 2017
Resolved
Vessels stability letter addendum is inaccurate (does not account for weight of dive gear).
Action required: 705 - Other - as specified
Resolved 23 October 2017
Resolution: MSC reviewed the vessels stability data and issued a revised stability letter dated October 18, 2017.
Navigation › Piloting/Steering › Marine Charts
Issued 17 April 2017
Resolved
Vessel did not carry current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 19 April 2017
Resolution: Owner/operator provided proof of purchase for marine charts.
Lifesaving › Lifefloat › Capacity
Issued 17 April 2017
Resolved
Vessel did not have life float capacity for 100% of persons on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 18 May 2017
Resolution: Replaced life floats with 50-man IBA.
Fire Fighting › Ventilation Systems › Ducts
Issued 17 April 2017
Resolved
Ventilation closures for machinery space ventilation was not vapor tight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 19 April 2017
Resolution: Vessels crew installed weatherstripping/gasket around perimeter of ventilation closure devices for machinery space ventilation ducts.