Records from 2016 to 2025. Most recent: inspection, 9 December 2025.
Inspection history · 16
9 December 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8280127
30 October 2024
Drydock Exam · Deficiency Check · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8026816
14 November 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7824328
3 November 2022
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7588519
4 November 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7344349
17 November 2020
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7096301
5 November 2019
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6847394
26 February 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6632752
24 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6615263
28 November 2018
Internal Structural Exam · Drydock Exam · Construction Oversight · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6588363
7 November 2018
Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6575955
24 April 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398581
14 March 2018
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6372035
6 March 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6367954
28 February 2018
Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6364123
30 November 2016
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6049654
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 November 2021
Resolved
Vessel that operates on the high seas must have a EPIRB with non-expired battery. EPIRB battery was expired. Provide non-expired battery for EPIRB.
46 CFR 180.64
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2021
Resolution: EPIRB with valid battery provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2021
Resolved
Installation of portable fire extinguisher must be in accordance with manufacture. Extinguisher not placed in bracket. Provide bracket for lower forward fire extinguisher.
46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 13 December 2021
Resolution: Bracket provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 November 2021
Resolved
Vessel shall have mounted at the operating station emergency instructions for fire, man over board conditions. Emergency instructions not posted. Provide emergency instructions.
46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 1 December 2021
Resolution: Emergency instructions provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 November 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Center bilge and engine room bilge #1 indicator lights not operational. Provide operational indicator lights for center bilge and engine room bilge #1.
46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 5 November 2021
Resolution: Indicator lights operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 November 2021
Resolved
Construction of vessel must allow for safe operation. Aft swim step bracket weld cracked all around. Make proper repairs to cracked bracket.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 10 November 2021
Resolution: Bracket repair provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 November 2020
Resolved
Port side engine room natural ventilation did not have a means of closing. Provide closure device for port side engine room natural ventilation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2020
Resolution: Means of closing provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 November 2020
Resolved
First aid kit missing and had expired items. Provide new first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2020
Resolution: First aid items provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2020
Resolved
Engine room pre-engineered fixed firefighting system was not fully charged. Provide charged and serviced pre-engineered fixed firefighting system for engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2020
Resolution: Fire boy charged.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2020
Resolved
Fire extinguishers past service date. Provide servicing on all fire extinguishers past service date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2021
Resolution: New extinguisher installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 November 2020
Resolved
Visual auto bilge indicator for center bilge not operational at helm. Provide visual indication for auto bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2020
Resolution: Bilge indicator operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 November 2020
Resolved
Life Float damage to shell/covering. Make repairs to life float with approved repair products from Life Float manufacturer.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2020
Resolution: Life float repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 November 2019
Resolved
The weak link for the vessel's life float was in disrepair and unserviceable. Replace in kind in accordance with 46 CFR 180.130.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 18 November 2019
Resolution: Weaklink replaced
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 November 2019
Resolved
The remote fuel shutoff station was not labeled. Label the remote emergency fuel shut off station in accordance with 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 18 November 2019
Resolution: Label installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 January 2019
Resolved
Engine compartment audible high water alarm was inoperative. Repair in accordance with 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2019
Resolution: Alarm repaired during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 January 2019
Resolved
4 red flares were expired. Renew in accordance with 46 CFR 180.68.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2019
Resolution: 4 red flares were provided during inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 January 2019
Resolved
Fireboy audible alarm is inoperative. Repair in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
Resolution: Fireboy audible alarm repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 January 2019
Resolved
Fireboy was not serviced. Service in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Fireboy serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 January 2019
Resolved
Ringbuoy was missing vessel name. Mark in accordance with 46 CFR 185.604.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
Resolution: Ring buoy was marked with vessel name.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 January 2019
Resolved
DSC VHF radio was not programmed. Prove proper operation in accordance with 46 CFR 184.502.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: DSC radio programmed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 January 2019
Resolved
Current Light List and Coast Pilot were not provided. Provide in accordance with 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Current Light List and Coast Pilot provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019
Resolved
Oil Discharge placard was not mounted. 33 CFR 155.450.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Oil Discharge placard mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019
Resolved
MARPOL V placard(garbage) was not mounted. 33 CFR 151.59
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: MARPOL V placard mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019
Resolved
Emergency Instruction List was not provided. 46 CFR 185.510.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Emergency Instruction List provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019
Resolved
Emergency Broadcast Placard not mounted. 46 CFR 184.506
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Emergency Broadcast placard mounted.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 March 2018
Resolved
Engine room bilge audible alarm is inoperative. Repair in accordance with 46CFR 182.530. Check compartment every 20mins during operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 14 March 2018
Resolution: Unit renewed. Audible alarm repaired.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 March 2018
Resolved
Emergency fuel shut-off valve does not close completely. Repair in accordance with 46CFR 182.455.
Condition: Improper/Lack of Maintenance
Due 16 March 2018
Resolved 14 March 2018
Resolution: Valve closes completely.
Documentation › Certificates/Documents › FCC SSL
Issued 6 March 2018
Resolved
Station License not present. Provide in accordance with 47 CFR.
Condition: Invalid
Due 16 March 2018
Resolved 16 March 2018
Resolution: Receipt for License provided.