MAURY USCG vessel records
← All vessels

COOPER V

COOPER V is a 2007 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in December 2025, along with 27 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 9 December 2025.

Built
2007
Last inspected
9 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD7599
877777
Flag
UNITED STATES
Maury page id
psix-877777

Documentation record

Registered dimensions (L × B × D)31.1 ft × 10.3 ft × 5.3 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPREMIUM BOAT COMPANY INC · CAPE CORAL, FL, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

9 December 2025 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8280127
30 October 2024 Drydock Exam · Deficiency Check · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8026816
14 November 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7824328
3 November 2022 Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7588519
4 November 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7344349
17 November 2020 Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7096301
5 November 2019 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6847394
26 February 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6632752
24 January 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6615263
28 November 2018 Internal Structural Exam · Drydock Exam · Construction Oversight · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6588363
7 November 2018 Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6575955
24 April 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398581
14 March 2018 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6372035
6 March 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6367954
28 February 2018 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6364123
30 November 2016 Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6049654

Deficiency record · 27

05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 November 2021 Resolved
Vessel that operates on the high seas must have a EPIRB with non-expired battery. EPIRB battery was expired. Provide non-expired battery for EPIRB. 46 CFR 180.64
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2021
Resolution: EPIRB with valid battery provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2021 Resolved
Installation of portable fire extinguisher must be in accordance with manufacture. Extinguisher not placed in bracket. Provide bracket for lower forward fire extinguisher. 46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 13 December 2021
Resolution: Bracket provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 November 2021 Resolved
Vessel shall have mounted at the operating station emergency instructions for fire, man over board conditions. Emergency instructions not posted. Provide emergency instructions. 46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 1 December 2021
Resolution: Emergency instructions provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 November 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Center bilge and engine room bilge #1 indicator lights not operational. Provide operational indicator lights for center bilge and engine room bilge #1. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 5 November 2021
Resolution: Indicator lights operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 November 2021 Resolved
Construction of vessel must allow for safe operation. Aft swim step bracket weld cracked all around. Make proper repairs to cracked bracket. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 10 November 2021
Resolution: Bracket repair provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 November 2020 Resolved
Port side engine room natural ventilation did not have a means of closing. Provide closure device for port side engine room natural ventilation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2020
Resolution: Means of closing provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 November 2020 Resolved
First aid kit missing and had expired items. Provide new first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2020
Resolution: First aid items provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2020 Resolved
Engine room pre-engineered fixed firefighting system was not fully charged. Provide charged and serviced pre-engineered fixed firefighting system for engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2020
Resolution: Fire boy charged.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 November 2020 Resolved
Fire extinguishers past service date. Provide servicing on all fire extinguishers past service date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2021
Resolution: New extinguisher installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 November 2020 Resolved
Visual auto bilge indicator for center bilge not operational at helm. Provide visual indication for auto bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2020
Resolution: Bilge indicator operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 November 2020 Resolved
Life Float damage to shell/covering. Make repairs to life float with approved repair products from Life Float manufacturer.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2020
Resolution: Life float repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 November 2019 Resolved
The weak link for the vessel's life float was in disrepair and unserviceable. Replace in kind in accordance with 46 CFR 180.130.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 18 November 2019
Resolution: Weaklink replaced
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 November 2019 Resolved
The remote fuel shutoff station was not labeled. Label the remote emergency fuel shut off station in accordance with 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 18 November 2019
Resolution: Label installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 January 2019 Resolved
Engine compartment audible high water alarm was inoperative. Repair in accordance with 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2019
Resolution: Alarm repaired during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 January 2019 Resolved
4 red flares were expired. Renew in accordance with 46 CFR 180.68.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2019
Resolution: 4 red flares were provided during inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 January 2019 Resolved
Fireboy audible alarm is inoperative. Repair in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
Resolution: Fireboy audible alarm repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 January 2019 Resolved
Fireboy was not serviced. Service in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Fireboy serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 January 2019 Resolved
Ringbuoy was missing vessel name. Mark in accordance with 46 CFR 185.604.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2019
Resolution: Ring buoy was marked with vessel name.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 January 2019 Resolved
DSC VHF radio was not programmed. Prove proper operation in accordance with 46 CFR 184.502.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: DSC radio programmed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 January 2019 Resolved
Current Light List and Coast Pilot were not provided. Provide in accordance with 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Current Light List and Coast Pilot provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019 Resolved
Oil Discharge placard was not mounted. 33 CFR 155.450.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Oil Discharge placard mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019 Resolved
MARPOL V placard(garbage) was not mounted. 33 CFR 151.59
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: MARPOL V placard mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019 Resolved
Emergency Instruction List was not provided. 46 CFR 185.510.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Emergency Instruction List provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019 Resolved
Emergency Broadcast Placard not mounted. 46 CFR 184.506
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2019
Resolution: Emergency Broadcast placard mounted.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 March 2018 Resolved
Engine room bilge audible alarm is inoperative. Repair in accordance with 46CFR 182.530. Check compartment every 20mins during operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 14 March 2018
Resolution: Unit renewed. Audible alarm repaired.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 March 2018 Resolved
Emergency fuel shut-off valve does not close completely. Repair in accordance with 46CFR 182.455.
Condition: Improper/Lack of Maintenance
Due 16 March 2018
Resolved 14 March 2018
Resolution: Valve closes completely.
Documentation › Certificates/Documents › FCC SSL
Issued 6 March 2018 Resolved
Station License not present. Provide in accordance with 47 CFR.
Condition: Invalid
Due 16 March 2018
Resolved 16 March 2018
Resolution: Receipt for License provided.

Ownership record