Records from 2016 to 2026. Most recent: inspection, 23 February 2026.
Inspection history · 39
23 February 2026
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8314032
26 August 2025
PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8208926
3 March 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8085697
3 February 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8073927
29 January 2025
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8104543
11 October 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8017836
9 September 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7999285
29 August 2024
COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7987699
25 August 2024
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7989618
26 June 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7942632
19 April 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7898105
19 April 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7898304
10 March 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7876626
1 March 2024
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7871936
2 October 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7801762
2 September 2023
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7782437
25 April 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7675514
3 March 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7644510
31 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7586464
11 September 2022
PSC B · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7553378
29 May 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7476192
27 March 2022
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7415831
16 September 2021
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7311153
6 May 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6949003
4 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6935468
29 March 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6932917
15 March 2020
COC-CVE Annual
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6920759
15 September 2019
Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6808402
17 March 2019
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6636753
16 September 2018
COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6540723
25 March 2018
ISPS II Exam · Ballast Water Examination · COC-CVE Annual · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6369098
24 September 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6266832
26 March 2017
COC-CVE Annual · ISPS III Exam · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6104543
29 January 2017
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6079070
15 January 2017
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6071190
25 September 2016
ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6005189
1 May 2016
Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 5866737
27 March 2016
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5840439
9 February 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5812027
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 February 2026
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and capable of closing with an angle inclination of up to 3.5 degrees opposing closure.
PSCO observed galley door 4.8.10 failed to close.
74 SOLAS 20 II-2/9.4.1.1.5.1
10(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 February 2026
Resolution: galley door 4.8.10 was serviced and properly closed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 August 2025
Resolved
Openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed fire door 1.1.05 did not latch completely.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 August 2025
Resolution: Vessel crew adjusted door hinge allowing the door to properly secure prior to the completion of the exam.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 March 2025
Resolved
EVERY CREW MEMBER WITH ASSIGNED EMERGENCY DUTIES SHALL BE FAMILIAR WITH THESE DUTIES BEFORE THE VOYAGE BEGINS. THREE (03) STAIRWAY GUIDES ASSIGNED TO DECK 8 PASSENGER STAIRWAY AND THREE (03) LIFE-RAFT CREW MEMBERS ASSIGNED TO LIFE-RAFT 32 WERE NOT FAMILIAR WITH SHIP'S EMERGENCY PROCEDURES DURING AN ABANDON SHIP.
74 SOLAS 20 III/19.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2025
Resolved 5 March 2025
Resolution: Def resolved, class documents uploaded attesting to training provided to crew members.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 March 2025
Resolved
EVERY SHIP OF 12 M OR MORE IN LENGTH OVERALL AND FIXED OR FLOATING PLATFORMS SHALL DISPLAY PLACARDS WHICH NOTIFY THE CREW AND PASSENGERS OF THE DISCHARGE REQUIREMENTS OF REGULATIONS 3,4,5 & 6 OF THIS ANNEX. MARPOL PLACARD WAS NOT DISPLAY IN REMBRANDT DINING GALLEY LOCATED IN DECK 3 ZONE 6.
MARPOL 2017 ZNNEX V/10.1
Action required: 10 - Deficiency Rectified
Resolved 3 March 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 August 2024
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersetions. Observed low location lighting in kid club area nont operating and deck 8 stbd between mvz 3 and 4, working intermitten.
74 solas 20 II-2/13.1.2.5.1
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 4 September 2024
Resolution: Rcvd class report attesting to repairs
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 29 August 2024
Resolved
Machinery, boilers and other pressure vessels shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and o ther hazards. Observed active pinhole leak on porable water cold line.
74 solas 04 II-1/26.1
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 4 September 2024
Resolution: Rcvd class report attesting to repairs
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 29 August 2024
Resolved
The master, owner, operator agent or person-in-charge of all vessels equipped with ballast water tanks that operate in the waters of the U.S. must...remove fouling organisms from the vessel's hull...observed excessive growth on hull beneath the waterline.
CG006
33CFR151.2050
50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2024
Resolved 11 October 2024
Resolution: Vessel satisfactorily cleaned hull of ship. See attached document for further details.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 August 2024
Resolved
Fire-extinguishing appliances shall be readily available. Observed furniture blocking fire appliance in fuel kids club.
74solas20 II-2/10.1.1.2
10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 29 August 2024
Resolved 29 August 2024
Resolution: removed furniture from fire appliance
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 29 August 2024
Resolved
Machinery, boilers and other pressure vessels shall be so installed and protected as to reduce to a miniumum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Observed wasted pinhole on sewage overflow line from mixing tank.
74SOLAS04 II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 August 2024
Resolved 29 August 2024
Resolution: repaired pinhole leak
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 March 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage beings. Crewmembers were unaware of cabin evacuation procedures IAW shipboard protocols. Crewmembers were not able to utilize clearance cards for cabine, unable to explain instructions for decent devices, and failed to communicate properly with the Evacuation Control Center (ECC) for special needs requireing limited accessibility including wheelchairs.
74 SOLAS (20) III/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2024
Resolved 1 March 2024
Resolution: Additional crew training was provided.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2024
Resolved
Cabin doors in "B" class divisions shall be of a self-closing type. Hold-back hooks are not permitted. Cleaning crew failed to remove door hold-backs during the drill.
74 SOLAS (20) II-2/9.4.1.2.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2024
Resolved 1 March 2024
Resolution: Hold-backs were removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 March 2024
Resolved
Safe escape routes shall be provided. The photo gallery office on deck 4 does not meet the requirements of being able to safely and swiftly escape to the lifeboat and life raft embarkation deck. The room leads to the photo gallery room which is a category 8 space.
74 SOLAS (20) II-2/13.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2024
Resolved 19 April 2024
Resolution: Class report attesting to the alarm placed into photo galley to allow safe escape.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 March 2024
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionall, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. Multiple stripes of low location lighting in the crew berthing corridor aft of the carpenter space (deck 1, fire zone 3) were not operating properly.
74 SOLAS (20) II-2/13.3.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 March 2024
Resolution: Low location lighting was repaired.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 March 2024
Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. PSCOs observed a laundry cart obstructing an escape route from the spa on deck 12.
74 SOLAS (20) II-2/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 March 2024
Resolution: Laundry cart was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The shuttle on lifeboat #29 could not fully turn to port during the operational test of the life boats steering gear.
74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 March 2024
Resolution: The shuttle was repaired and a satisfactory test of the life boats steering gear was conducted.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 September 2023
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. multiple areas of low location lighting found extinguished throughout the ship.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 September 2023
Resolved 2 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 September 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, hold-back hooks not subject to central control station release are prohibited. PSCO's observed fire screen door 1.7.17 tied open. The door is listed on the fire control plan as self closing.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 September 2023
Resolved 2 September 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 March 2023
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements must be met;fire protection systems and firefighting systems and appliances shall be maintained ready for use. High pressure water mist nozzles on deck 12 SKY Bar were severely corroded.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 March 2023
Resolution: Corroded nozzles in SKY bar were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 March 2023
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces , such spaces are classified according to their fire risk as shown in categories (1) to (14) below. Category 9 space on deck one , fire zone 3 in way of stairway was being used as a category 13 space for stowage.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 March 2023
Resolution: Room was emptied to meet criteria for cat 9.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 March 2023
Resolved
Before this ship leaves port and at all times during the voyage , all life-saving appliances shall be in working order and ready for immediate use. life boat 13 was not able to steer under means of primary steering
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 March 2023
Resolution: life boat 13 was fixed while on board and able to be steered using primary means.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 March 2023
Resolved
Doors and door frames in " B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. "B-15" class door located in the stairway on deck 1, fire zone 3 did not close.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 3 March 2023
Resolution: b-15 door was fixed by carpenter and closes as appropriate.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2022
Resolved
FIXED FIRE-EXTINGUISHING SYSTEMS SHALL BE INSTALLED HAVING DUE REGARD TO THE FIRE GROWTH POTENTIAL OF THE PROTECTED SPACES AND FIRE-EXTINGUISHING APPLIANCES SHALL BE READILY AVAILABLE. PSCO OBSERVED 7 SPRINKLER HIGH FOG SPRINKLER HEADS WITH WHITE PAINT COVERING THE NOZZLES.
74 SOLAS(20)II-2/10.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 September 2022
Resolved 11 September 2022
Resolution: RESOLVED ON SPOT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 September 2022
Resolved
MEANS OF ESCAPE FROM CONTROL STATIONS, ACCOMMODATION SPACES AND SERVICE SPACES. ESCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. PSCO OBSERVED FURNITURE BLOCKING ESCAPE ROUTE/ESCAPE DOOR ON DECK 14 IN THE SUITE LOUNGE.
74SOLAS(20)II-2/13.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 11 September 2022
Resolved 11 September 2022
Resolution: RESOLVED ON SPOT.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 11 September 2022
Resolved
ALL LIFE-SAVING APPLIANCES AND ARRANGEMENTS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE CODE. PSCO OBSERVED 03 WATER RATIONS LEAKING IN LIFEBOAT NUMBER 26.
74SOLAS(20)III/34.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 September 2022
Resolved 11 September 2022
Resolution: DAMAGED RATIONS REPLACED ON THE SPOT.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 September 2018
Resolved
0750 - Fire doors in main vertical zone bulkheads, galley boundries and stairway enclosures other than power operated watertight dorrs and those which are normally locked shall satisfy the following requirements. The door shall be self closing and be capable of closing with an angle of up to 3.5 degrees oppsoing closure. Fire door 1.1.05 does not self close. SOLAS (14) II-2/9.4.1.5.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 16 September 2018
Resolution: Vessel fixed fire door and demonstrated proper closure of it.
Lifesaving › Lifeboat › Cooling Air Duct System
Issued 25 March 2018
Resolved
Maintenance, testing, and inspections of life-saving appliances shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring reliability of such appliance. Lifeboat 29 keel cooler for engine was found detached from mounting bracket.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 20 April 2018
Resolution: Provided class report attesting to the proper repair of the cooling pipe on the #29 lifeboat.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 25 March 2018
Resolved
A copy of the documentation as approved by the administration indicating that the alternative design and arrangements comply with this regulation shall be carried on board the ship. Copy of the document indicating the alternative design as perscribed in the PSSC was not found on board.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 20 April 2018
Resolution: Vessel provided class doc stating that the vessel now has onboard the correct documentation.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 24 September 2017
Resolved
The normal equipment of every lifeboat shall consist of: food ration for each person the lifeboat is permitted to accomodate; these rations shall be kept in airtight packaging and be stowed in a watertight container. Several lifeboats were found with multiple food rations not meeting the airtight requirement. SOLAS (14) Ch. III/13.1.4 LSA (17) Ch. IV/4.4.8 Action: 16AC
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 October 2017
Resolved 8 October 2017
Resolution: Submitted class report, see attached.
Lifesaving › Lifeboat › Hull
Issued 24 September 2017
Resolved
All lifeboats shall be of sufficient strength to enable them to be safely launched into the water when loaded with their full complement of persons and equipment. Lifeboat #26 was observed to have a crack appox. 16 inches long in the forward starboard side, topside of gunwale fractured gel coat and fiberglass mat. SOLAS (14) Ch. III/21.1.1.1 LSA (17) Ch. IV/4.4.1.3 Action taken: 16 AC
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 October 2017
Resolved 8 October 2017
Resolution: Submitted class report, see attached.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 26 March 2017
Resolved
0750 - Fire Prevention - Openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fire as the divisions in which they are fitted. MVZ#5 movable fire wall across promenade area was obstructed by confetti wedged in track and did not completely close, leaving A-class MVZ boundary not set.- 74 SOLAS (09) II-2/9.4.1.1.1 - 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 March 2017
Resolution: Confetti cleared and wall retested satisfactorily.
Fire Fighting › Means of Escape › Doorways
Issued 26 March 2017
Resolved
0999 -Other Safety- Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of force in the direction of escape flow. Escape doors from main dining room leading to the exterior deck had thumbscrews on doors.-74(09)II-2/13.3.2.6.2
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 2 April 2017
Resolution: Class report was submitted attesting to the removal of thumb screws from all escape doors in public areas.
Lifesaving › Lifeboat › Propulsion Transmission
Issued 15 January 2017
Resolved
before leaving port all life-savings appliances shall be in working adn ready for immediate use; life boat #27 is inoperable due to damaged propulison gear box. 74SOLAS(14) CH.III/20.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 29 January 2017
Resolution: LifeBoat #27 was tested. ALL SAT. Video and photos of operation was also verified. ALL SAT.
Fire Fighting › Means of Escape › Blocked
Issued 25 September 2016
Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Obstruction was found outside the crew gym to crews recreation area. Obstruction was also found on Deck 3 Port Side, main dining room. A table and chairs blocking escape route. SOLAS 14, CH II-2 Reg 13.1.2. Action take 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 25 September 2016
Resolution: Crew cleared the obstructions on the spot.
Fire Fighting › Means of Escape › Blocked
Issued 27 March 2016
Resolved
0960-Stairway enclosure in accomodation and service spaces shall have direct access from the corridors and be of a sufficient area to prevent congestion. Stairway adjacent to FD 2.8.06 had a sign blocking access to the stairway. SOLAS(09) CH II-2 REG 13.3.2.3 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 27 March 2016
Resolution: Crew moved the sign blocking the stairway on the spot.
Fire Fighting › Fire Hoses › Location
Issued 27 March 2016
Resolved
0720-In interior locations in passenger ships carrying more than 36 passengers, fire hoses shall be connected to hydrants at all times. Fire hoses not available at locations TT-4.5. SOLAS (09) CH II-2 REG 10.2.3.1.1 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 27 March 2016
Resolution: Crew placed spare hose where it was missing.