Records from 2017 to 2025. Most recent: inspection, 23 September 2025.
Documentation record
Registered dimensions (L × B × D)163.0 ft × 30.0 ft × 14.0 ft
Registered tonnagegross 97 / net 65
ITC dimensions (L × B × D)163.0 ft × 30.0 ft × 14.0 ft
ITC tonnagegross 416 / net 124
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it416 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
124 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
23 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8238706
16 September 2025
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8234930
11 August 2025
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8207737
16 October 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8019655
4 December 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7828766
18 September 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7793839
12 September 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7554091
22 October 2021
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7337270
12 August 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7031323
16 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6835002
2 October 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6826158
3 May 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6679045
7 November 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6576760
10 October 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6284392
3 October 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6280526
1 March 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6097142
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2024
Resolved
Fuel filters fitted with bowls of other than steel must be approved by Commandant. Flame shield required. 04 Flame shields missing on inboard Port M/E.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 October 2024
Resolved 16 October 2024
Resolution: Engineer had flame shields in the rudder room. Installed prior to completion of inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 4 December 2023
Resolved
A vessel must comply with the applicable requirements for any radio installation to include requirements for station license & install certificates issued by the FCC set forth in 47 CFR part 80. Master did not have a Marine Radio Operator Permit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2023
Resolution: Vessel provided proof of MROP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2023
Resolved
Equipment installed on each vessel must be maintained to provide adequate protection and satisfactory arrangement for draining any watertight compartment. Strainer for bilge pump was leaking water from the base.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2023
Resolved 5 December 2023
Resolution: Received proof of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2023
Resolved
Equipment installed on each vessel and maintained to provide adequate protection from causing a fire or explosion. Starboard aft lube oil tank vent on deck not properly secured.
Action required: 10 - Deficiency Rectified
Resolved 4 December 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 September 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull.
-Found multiple cracks and cracked welds on the #1-4 P and S engine room exhaust overboards and piping.
-Found exhaust overboard on S side of gen room to haved cracked welds.
-Found multi cracked welds on transom in stern on P side.
46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2022
Resolved 14 September 2022
Resolution: Ground/reweld
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 September 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull.
-Found water tight hatch on S side in oil room to have excessive corrosion due to disimiliar metals in bolt holes.
46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2022
Resolved 14 September 2022
Resolution: cropped/renewed/dye penn.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 August 2020
Resolved
As appropriate for the intended voyage, a vesesl must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; Vessel had out of date charts for their AOR; Provide up-to-date nautical charts for AOR prior to departure; To the satisfaction of the OCMI.
Action required: 10 - Deficiency Rectified
Due 12 August 2020
Resolved 12 August 2020
Resolution: Vessel captain provided photographic proof of nautical charts corrected through the most recent NTM and LNM.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 12 August 2020
Resolved
All vessels with overnight accommodations must be equipped witha general alarm system; General alarm system bell on the main deck was not operablel Make general alarm system operable IAW 46 CFR 183.550 prior to departure; To the satisfaction of the OCMI.
Action required: 10 - Deficiency Rectified
Due 12 August 2020
Resolved 12 August 2020
Resolution: Crew was able to effect repairs so alarm would ring properly.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 August 2020
Resolved
Two (02) life floats were not properly marked with Type II SOLAS retroflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 4 September 2020
Resolution: Vessel rep provided photographic evidecne of proper retrorelective tape being attached.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 August 2020
Resolved
Entrances to spaces storing, protected by, or spaces adjacent into which cardbon dioxide might migrate were not properly marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 4 September 2020
Resolution: Vessel rep provided photograhic evidence of CO2 placards being installed.