Records from 2008 to 2026. Most recent: inspection, 24 April 2026.
Documentation record
Registered dimensions (L × B × D)133.2 ft × 28.0 ft × 12.1 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)133.2 ft × 28.0 ft × 12.1 ft
ITC tonnagegross 295 / net 88
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 2008
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFREEPORT, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
295 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
88 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
24 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8355296
31 July 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8186321
20 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7915427
6 May 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7908041
9 May 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7678569
9 May 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7447131
2 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7442146
9 November 2021
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7348292
27 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7207966
22 January 2021
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7129024
21 August 2020
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7044596
27 May 2020
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6962026
29 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6945607
24 June 2019
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6733370
2 May 2019
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6675505
20 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6646155
17 May 2018
Internal Structural Exam · Drydock Exam · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6419982
7 April 2017
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6119850
22 February 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6301521
7 June 2016
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5901989
17 June 2014
Internal Structural Exam · Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4891553
12 June 2012
Hull Examination · Internal Structural Exam · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4340648
18 February 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3681773
21 January 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3667289
14 July 2008
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3268046
12 July 2008
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3265431
12 July 2008
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3331014
8 May 2008
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3201830
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 May 2023
Resolved
essels that operate on a Coastwise or Oceans route must conduct emergency egress training for each member of the crew at least monthly and each time a new crew member joins such vessel. This training must be completed and logged in accordance with CG regulations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 17 May 2023
Resolution: Vessel Master conducted emergency egress training with crew and properly logged it in the vessel log.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 May 2023
Resolved
Found cracked welds in the port and starboard side wing voids, by the kitchen, in the exact location on both sides, top forward corner where bulkhead meets the sideshell. The cracked weld in the starboard side extended into the first longitudinal deck frames. Cracked welds and affected structural members must be repaired in accordance with CG regs and ABS Guidelines.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 17 May 2023
Resolution: Cracked welds and frames were properly fixed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2023
Resolved
A vessel that operates on an Oceans route must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces. Crew accommodation spaces that don't have interconnected fire detectors must be properly fitted with required detectors per CG regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 9 June 2023
Resolution: Interconnected fire detectors were installed in the wheelhouse, galley, staterooms, and passenger area and where integrated to the vessels Fire Alarm Panel in the bridge.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 9 May 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation giving consideration to provisions for protection against fire. Although fire pump is operable it must be fixed to address water leak of pump shaft and valve on fire station #17.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2023
Resolved 17 May 2023
Resolution: Pump shaft seal was replaced and is now leak free; valve of fire station #17 was replaced with a new one and is now leak free.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 27 May 2021
Resolved
PORT and STBD rescue area has cracking at the deck edge and rub rails. #3 main engine exhaust hanger had a cracked weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2021
Resolved 1 June 2021
Resolution: Cracked welds were ground out and rewelded.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 May 2021
Resolved
Engine room and generator room not marked with proper verbiage; steering gear room not properly marked with proper storage verbiage.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 1 June 2021
Resolution: Correct CO2 placards were installed on engine room and generator room WTDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2021
Resolved
One life right had deteriorated Type II retroreflective strip.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2021
Resolved 27 May 2021
Resolution: Reflective strip replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 May 2021
Resolved
Life floats need proper material for spacers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2021
Resolved 27 May 2021
Resolution: Proper dunnage wood was used to replace spacers.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 May 2021
Resolved
Proper securing device neet to be attached to each paddle.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 May 2021
Resolved 27 May 2021
Resolution: Correct securing ties installed to each paddle.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 June 2012
Resolved
The vessel has several cracks in the forward swash bulkhead of the aft ballast water tank on the STBD side. The vessel representative was allowed to drill stop and weld up the cracks in the swash bulkhead. The vessel is required to crop and renew this section of the swash bulkhead (2'4').
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 September 2012
Resolved 9 August 2012
Resolution: Swash bulkhead was inserted.
Construction/Loadline › Hull › Side Shell
Issued 12 July 2008
Resolved
Repair damaged area to forward portside bow prior to conducting cargo operations.
Crop and renew damaged "fractured" area of side shell.
Replace tripped underdeck longitudinal
Replace tripped sideshell longitudinal
Repair deck plate were damaged
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2008
Resolved 22 July 2008
Resolution: All repairs completed and tested.