Inspection history · 10
21 September 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6272663
21 September 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6299773
5 May 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6139581
29 November 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6049574
15 November 2016
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6042020
15 November 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6051905
31 May 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5892653
3 May 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5868308
14 January 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797711
11 January 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5795391
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 21 September 2017
Resolved
74SOLAS (cons. 2014) CHII-1 Reg. 26- Means shall be provided wherby normal operation of propulsion machinery can be sustained or restored even though one o fthe eddental suxiliaries becomes inoperative. Vessel experianced a loss of propulsion while pulling into berth.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2017
Resolution: recieved class report attesting to the diagnoses and repair of the main engine start air.
Construction/Loadline › Markings › Load Line Mark
Issued 6 May 2017
Resolved
1966 ICLL/8 40ac The ring, lines, and letters shall be painted in white or yellow on a dark ground, or in black on a light ground. Deck line mark on hull was not painted in contrasting colors.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: Recieved class report attesting to the repair.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 May 2017
Resolved
1966 ICLL/25(2) 40ac Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. The guard rail on the starboard side at cargo bay #22 towards the bow was wasted and not completely attached.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: Recieved class report attesting to the repair.
Lifesaving › Lifebuoys › Immediately Available
Issued 6 May 2017
Resolved
74SOLAS (2014 CONS. ED.) III/7.1.1.2 40ac Life buoys complying w/ the requirements of paragrph 2.1.1 of the Code shall be so stowed as to be capable of being rapidly cut loose, and not be permanently secured in any way. 03 lifebuoys were directly tied to the railing.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: Recieved class report attesting to the repair.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 May 2017
Resolved
74SOLAS (2001 CONS. ED.) II-2/20.1 40ac In all ships general arrangement plans shall be permanently exhibited for the guidance of the sip's officers. Multiple firefighting appliances have damaged labels obscuring the identity of the appliance.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: Recieved class report attesting to the repair.
Deck/Cargo › Cargo Stowage › General
Issued 5 May 2017
Resolved
74SOLAS (2001 CONS. ED.)VI/5.1 17ac Cargo and cargo units on or under deck shall be so loaded, stowed and secured as to prevent as far practicable, throughout the voyage, damage or hazard to the ship and the person on board, and loss of cargo overboard. Container lashings not properly secured, allowing lashings to go under compression during roll periods.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2017
Resolution: Container lashing onboard the vessel, now followed lashing pattern as per approved
Cargo securing Manual. Securing, visually inspected and found in order. Confirmation from master received, this will be strictly followed further.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 15 November 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel had disconnect between the bridge and engine room telegraph causing loss of astern propulsion; Specific cause to be determined.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2016
Resolution: Recieved satisfactory classification report.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 May 2016
Resolved
74 SOLAS (04 Cons Ed)II-1/29.12.2 | 40(a)(c) Hydraulic power-operated steering gear shall be provided with the following: a low-level alarm...No audible alarms were given on the navigation bridge after the hydraulic low-level alarm was tested.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 May 2016
Resolution: Received Class Survey stating that all alarms - audible and visual - are fully operational.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 14 January 2016
Resolved
Vessel has an inoperable echo depth sounder
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 February 2016
Resolution: Exchanged the broken transducer to a new one with diver assistance.