HATTERAS TRADER

HATTERAS TRADER is a 2008 tank ship. The Coast Guard has recorded 51 inspections since 2016, most recently in May 2026, along with 35 deficiencies, 6 operational controls and 9 casualty investigations between 2008 and 2024.

Records from 2008 to 2026. Most recent: inspection, 1 May 2026.

Built
2008
Last inspected
1 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9353541
878765
Flag
UNITED STATES
Maury page id
psix-878765

Documentation record

Registered dimensions (L × B × D)576.0 ft × 105.6 ft × 61.7 ft
Registered tonnagegross 29,242 / net 11,926
ITC dimensions (L × B × D)576.0 ft × 105.6 ft × 61.7 ft
ITC tonnagegross 29,242 / net 11,926
BuilderAKER PHILADELPHIA SHIPYARD INC · PHILADELPHIA, PA, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46809 - Dead Weight, Ton
29242 - Convention (Subpart B), Gross Ton
11926 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

51 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each; 6 operational controls with the dates imposed and removed; 2 vessels inspected with it, by name and date; 2 other recorded names, with years; 9 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENERGY ZEUS Towing Vessel · MISLE 828062 · 4 June 2020 · activity 6971462GASPARILLA Towing Vessel · MISLE 845821 · 4 June 2020 · activity 6971462

Inspection history · 51

1 May 2026 Administrative Inspection · Permit to Proceed
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8367838
21 February 2026 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8313753
9 December 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8279842
26 June 2025 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8161277
29 May 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8147116
9 May 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8131594
16 March 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8094437
7 March 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8090156
17 December 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8048558
5 August 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7974958
29 May 2024 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7922238
4 May 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7917039
13 September 2023 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7791013
22 July 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7749031
9 July 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7737080
9 May 2023 ACP COI Oversight · Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7684306
14 March 2023 Examination of Repairs · Administrative Inspection · MTSA/ISPS Verification · ACP Additional Oversight – Risk Assessment · ACP Drydock Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7650578
16 December 2022 In-Service Inspection · Administrative Inspection · ACP Additional Oversight – Risk Assessment · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7603137
28 November 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7600859
23 November 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7598911
4 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7571261
31 May 2022 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7457331
22 September 2021 Administrative Inspection · ACP Additional Oversight – Risk Assessment · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7314419
19 August 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7291424
26 July 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7270714
21 July 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7263119
24 May 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7205172
19 April 2021 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7178243
14 April 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7175100
17 March 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7154118
10 June 2020 ACP Periodic Oversight · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6967711
4 June 2020 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6971462
21 April 2020 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6944033
21 April 2020 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6944403
28 February 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6920007
3 January 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6882160
9 September 2019 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6807056
8 September 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6857842
15 August 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6784654
23 May 2019 Administrative Inspection · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6691287
11 May 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6682347
5 May 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6677455
1 August 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6503815
23 March 2018 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6376108
10 February 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6353273
5 September 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6281088
15 June 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6176384
9 June 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6162358
17 May 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6228729
6 May 2016 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5867971
13 January 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5829737

Deficiency record · 35

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 May 2024 Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted. Galley door that leads to scullery cannot self close or latch due to improper installation. Door was also found fitted with hold back hook. 74SOLAS(20)II-2/9.4.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2024 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers or in compartments assigned principally to accumulator batteries, in paint locker lockers, acetylene stores or similar spaces, unless the Administration is satisfied that such equipment is: appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. Vessel’s lighting fixture located outside the acetylene and oxygen lockers was installed with inadequate fittings (i.e. t-coupling, elbow, and nipples) that do not meet the explosion proof requirements. 74SOLAS(04)II-1/45.10.4
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2024 Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. Cable gland and wiring to the deck water seal float switch was installed with improper fittings and has wiring exposed(i.e. t-glads, coupling,) that do not meet the explosion proof requirements identified by the International Electrotechnical Commission (IEC) Publication 92. 74SOLAS(04)II-1/40.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 May 2024 Resolved
Electrical installations shall be such that: electrical services essential for safety will be ensured under various emergency conditions. Multiple emergency lights were observed to be not operational near embarkation areas for the lifeboat, rescue boat, and liferafts. 74SOLAS(04)II-1/40.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 May 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and rady for immediate use. The self contained air support system for the free fall lifeboat had a broken gauge rendering it unreadable and was leaking air into the boat at an uncontrollable rate. 74SOLAS(20)III/20.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2024 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensured under various emergency conditions. While testing the standby function for the no. 3 CFW pump running in auto change mode, the pump was not able to start up automatically. 74SOLAS(04)II-1/40.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 July 2023 Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. The main source of power shall consist of at east two generating sets. Vessel reported failure of main circuit breakers for No.2 and No.3 main diesel generators. Vessel to conduct repairs to the satisfaction of RO. 74 SOLAS (41) II-1/41.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 May 2023 Resolved
Fire Protection systems and fire-fighting systems and appliances shall be maintained ready for use. Vessels water mist system indicating system fault relating to the Pump Starter Motor. 74 SOLAS(08)II-2/14.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2023 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Auxiliary boiler inoperable at time of inspection, unable to complete testing of equipment. 74 SOLAS(08)II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 May 2023 Resolved
Illustrations and instructions in appropriate languages shall be posted in passenger cabins and be conspicuously displayed at muster stations and other passenger spaces to inform passengers of: the method of donning lifejackets. Marine Inspector discovered missing lifejacket donning instructions at lifeboat muster station. 74 SOLAS(20)III/8.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2023 Resolved
Waste receptacles shall be constructed of noncombustible materials with no openings in the sides of bottom. Several wastes receptacles throughout the ship were made of combustible materials(plastic). 74 SOLAS(08)II-2/4.4.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 May 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Ring buoy light located on the starboard cargo deck handrail.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 May 2023 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors that are weathertight/watertight when closed. Marine inspector noticed light coming through the weathertight/watertight doors within the superstructure when fully dogged down. ILLC(98)Annex I Chapter II/12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 May 2023 Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. Cable's penetrating fire divisions were incorrectly installed inside cable trunk on “D” deck. 74 SOLAS(08)II-2/9.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 May 2023 Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted. Aft galley door that leads to dry stores cannot selfclose or latch due to improper installation. 74 SOLAS(08)II-2/4.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 12 May 2023 Resolved
Protection of cargo tanks shall be achieved by a fixed inert gas system in accordance with the Fire Safety Systems Code(FSS) requiring the pressure of inert gas be continuously indicated. Vessels Kongsberg inert gas control screen is showing incorrect pressure readings for NO.2 C.O.T(P).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 16 December 2022 Resolved
The inert gas system referred to in paragraph 5.5.3.1 shall be designed, constructed and tested in accordance with the Fire Safety System Code. In addition to the requirements of paragraph 2.2.4.5, audible and visual alarms shall be provided to indicate: low water pressure or low water flow rate to the cooling and scrubbing arrangement. The low pressure cooling water inlet alarm was inoperable. 705 A- Prior to cargo operations. 74 SOLAS (04) 11-2/4.5.5.3.2 FSSC/15.2.3.2.2.3
Action required: 705 - Other - as specified
Due 23 December 2022
Resolved 23 December 2022
Resolution: The low cooling water pressure alarm switch was replaced with new spare OEM switch. Upon completion low cooling water alarm and shut down was demonstrated in accordance with PSTP; additionally, operation of the Inert Gas Generator was demonstrated; sat.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 16 December 2022 Resolved
A general emergency alarm system complying with the requirements of paragraph 7.2.1 of the Code shall be provided and shall be used for summoning passengers and crew to muster stations and to initiate the actions included in the muster list. The system shall be supplemented by either a public address system complying with the requirements of 7.2.2 of the Code or other suitable means of communication. The public address system shall be a loudspeaker installation enabling the broadcast of messages into all spaces where crew members or passengers, or both, are normally present, and to muster stations. The public address system on the Fore Mast was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, public address speaker was reattached to the Fore Mast including wiring. Mounting arrangements were examined and the public address system operation was demonstrated and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. MI observed the Port and Starboard weathertight doors of the A-Deck will not dog down. ICLL 88/16.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, crew adjusted the closing / dogging mechanism and operation was confirmed and sealing was demonstrated with chalk contact test and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Marine Inspector identified vent closure approximately 12” x 12” located on the bulkhead above and left of the Class I weathertight door for the Emergency Diesel Generator compartment with severely corroded/wasted knife edge for sealing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, sealing knife edge was repaired by weld build up, examined, operation was demonstrated and upon completion sealing was demonstrated with chalk contact test and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Marine Inspector identified knife edge on the Class I weathertight door for the Emergency Diesel Generator compartment that is corroded/wasted located on the bottom right of knife edge approximately 4” above the turn. ICLL 88/16.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, sealing knife edge was repaired by weld build up, examined, operation was demonstrated and upon completion sealing was demonstrated with chalk contact test and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Marine Inspector identified Class I watertight door for the Emergency Diesel Generator compartment with missing/corroded metal track for gasketing. ICLL 88/16.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, gasket retaining channel was repaired by cropping to fair and sound material and inserting the flat bar, examined, operation of the weathertight door was demonstrated and upon completion sealing was demonstrated with chalk contact test and
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 16 December 2022 Resolved
Every able seafarer deck serving on a seagoing ship of 500 GT or more shall be required to demonstrate the competence to perform the functions at the support level, as specified in column 1 of table A-II/5. The minimum knowledge, understanding and proficiency required of an able seafarer deck serving on a seagoing ship 500 GT or more is listed in column 2 of table A-II/5. The Ordinary Seaman handled lines during mooring operations without the proper STCW Endorsement (II/5). The vessel is appropriately manned with adequate personnel in accordance with the COI, however member should not have been utilized in the line handling position. STCW Part A-II/5.1 and 5.2
Action required: 10 - Deficiency Rectified
Resolved 16 December 2022
Resolution: Master made aware of the OS's current endorsements and advised not to utilize member for line handling during mooring ops.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 16 December 2022 Resolved
All persons who are assigned duty as officer in charge of a watch or as a rating forming part of a watch and whose duties involve designated safety, prevention of pollution and security duties shall be provided with rest period of not less than a minimum of 10 hours of rest in any 24 hour period. Hours of rest shall be at least 6 hours in length. As per the vessel's system (Watchkeeping) the C/E on NOV 23, 2022 did not receive 10 hours of rest in the previous 24 hour period and did not receive the minimum 6 hour rest period. STCW Part A-VIII/1.2 and 1.3
Action required: 10 - Deficiency Rectified
Resolved 16 December 2022
Resolution: Discrepancy noted per the SMS in vessel work/rest tracking system Watchkeeper.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 December 2022 Resolved
The machinery, boilers, and other pressure vessels associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Marine Inspector identified the #2 Framo engine for the cargo pump fuel oil supply hose to the racor filter assembly is dry rotted. At the fitting at the racor assembly the hose is cracked. Engineers replaced hose and demonstrated proper operation of the engine with no leaks and no other concerns. 74 SOLAS (04) II-1/26.1
Action required: 10 - Deficiency Rectified
Resolved 16 December 2022
Resolution: Hose Replaced prior to completion of inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 May 2022 Resolved
74 SOLAS (14) IX/3.1 ISM Code 10.1 A 30 The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. Master was unfamiliar with the contents of the vessel's SMS and unable to provide inspection reports, completed checklists for routine maintenance, or objective evidence that inspections and maintenance is being conducted to the watertight hatches and closures. Further, the Master was unable to locate SMS related material requiring assistance from the company in locating the SMS material. Due to the objective evidence in the below deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. An external audit conducted by the RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 1 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 31 May 2022 Resolved
ICLL (88) 16.1 A 30 All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such hatch covers shall be weather tight and fitted with gaskets and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. MI observed the watertight hatch for the Bosun space on the bow was not watertight. MI could feel air egressing from the space when dogged down. Crew conducted a hose test at 30 PSI which resulted in water ingress. MI observed the goose neck located at the Bow Centerline has irregularity on the knife edge preventing closure.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 31 May 2022 Resolved
ICLL (88) 19.4 A 30 Ventilator openings shall be provided with weather tight closing appliances of steel or other equivalent material. MI observed the natural ventilation mushroom head for the Bosun Store on the Starboard Bow is wasted and holed. MI observed the gasket for the power ventilation mushroom head for the Pant Stores wasted and corroded.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 June 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 May 2022 Resolved
74 SOLAS (04) II-1/ 26.1 A 50 The machinery, boilers, and other pressure vessels associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The #1 Framo cargo pump fuel oil supply hose is dry rotted/ cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2022 Resolved
74 SOLAS (04) II-1/45.1.1 A 50 Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. MI observed broken grounding wires on the Starboard side rescue boat muster station lighting. In addition, grounding wires to the controls of the Rescue Boat davit are corroded and broken. The power ventilation for paint and lamp stores has a disconnected ground wire. The tank heater locker power ventilation has a disconnected ground wire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 May 2022 Resolved
33 CFR 155.730 A 50 The vessel operator of each vessel required by § 155.720 to have transfer procedures shall maintain them current and shall require vessel personnel to use the transfer procedures for each transfer operation. Section 2, page 6 of vessel's transfer procedure requires " Top dead centerr of each flange bolt circle is a preventer pin designed to further identify these flanges as vapor recovery connections and not for the transfer of liquid cargo or ballast." Vapor recovery flange did not have a stud.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 31 May 2022 Resolved
74 SOLAS (14) III/ 20.2 C 10 Before the ship leaves port and at all times during the voyage, all life-saving appliance shall be in working order and ready for immediate use. MI observed the Port Bow embarkation ladder tie down strap was seized rendering it inoperable. In addition, securing shackles of the ladder were seized and unable to operate.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 31 May 2022 Resolved
74 SOLAS (14) II-2/ 10.4 10 C Ships constructed before 1 JUL 2014 shall comply with the requirements of this paragraph not later than the first survey after 1 JUL 2018: a minimum of two-way portable communications radiotelegraph apparatus for each fire party for the fire-fighter's communication shall be carried on board.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 22 September 2021 Resolved
A food ration totaling not less than 10,000 kJ for each person the lifeboat is permitted to accomodate. The rations shall be packed in a permanently sealed or vaccuum packed in a flexible packaging material. 10 out of 32 food rations found on board the lifeboat have lost their vaccuum seal. Replace food rations with new rations. SOLAS 74 (2020 Con. Ed.) III/13.1.4, LSA Code (2010) Ch. IV/4.4.8.12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 24 September 2021
Resolution: Referred to RO and received preliminary report for statutory condition to be rectified by 06OCT2021. Report attached under deficiencies/documents.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 September 2019 Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall comply with the following: The system shall be capable of being brought into operation from a position on the navigation bridge. Vessel experienced a non follow up of rudder on port steering pump. Provide transit plan and class report attesting to proper operation of steering system.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 September 2019
Resolved 11 September 2019
Resolution: Vessel provided class report attesting to proper operation of the steering system to the satisfaction of the attending marine inspector.

Casualty record · 9

17 March 2008Routine · role: Involved in a Marine Casualty · activity 3168852
14 August 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3575273
28 November 2013Routine · role: Involved in a Marine Casualty · activity 4770740
1 December 2015Routine · role: Involved in a Marine Casualty · activity 5773045
13 January 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5829737
1 August 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6503815
8 September 2019Routine · role: Involved in a Marine Casualty · activity 6857842
4 June 2020Routine · role: Involved in a Marine Casualty · activity 6971462
4 May 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7917039
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

OVERSEAS NEW YORK (2008–2020), SEAKAY VALOR (2024). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.