Records from 2008 to 2026. Most recent: inspection, 1 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 51
1 May 2026
Administrative Inspection · Permit to Proceed
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8367838
21 February 2026
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8313753
9 December 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8279842
26 June 2025
Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8161277
29 May 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8147116
9 May 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8131594
16 March 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8094437
7 March 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8090156
17 December 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8048558
5 August 2024
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7974958
29 May 2024
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7922238
4 May 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7917039
13 September 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7791013
22 July 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7749031
9 July 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7737080
9 May 2023
ACP COI Oversight · Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7684306
14 March 2023
Examination of Repairs · Administrative Inspection · MTSA/ISPS Verification · ACP Additional Oversight – Risk Assessment · ACP Drydock Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7650578
16 December 2022
In-Service Inspection · Administrative Inspection · ACP Additional Oversight – Risk Assessment · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7603137
28 November 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7600859
23 November 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7598911
4 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7571261
31 May 2022
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7457331
22 September 2021
Administrative Inspection · ACP Additional Oversight – Risk Assessment · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7314419
19 August 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7291424
26 July 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7270714
21 July 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7263119
24 May 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7205172
19 April 2021
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7178243
14 April 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7175100
17 March 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7154118
10 June 2020
ACP Periodic Oversight · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6967711
4 June 2020
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6971462
21 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6944033
21 April 2020
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6944403
28 February 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6920007
3 January 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6882160
9 September 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6807056
8 September 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6857842
15 August 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6784654
23 May 2019
Administrative Inspection · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6691287
11 May 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6682347
5 May 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6677455
1 August 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6503815
23 March 2018
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6376108
10 February 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6353273
5 September 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6281088
15 June 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6176384
9 June 2017
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6162358
17 May 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6228729
6 May 2016
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5867971
13 January 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5829737
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 May 2024
Resolved
The fire resistance of doors shall be equivalent to that
of the division in which they are fitted.
Galley door that leads to scullery cannot self close or
latch due to improper installation. Door was also found
fitted with hold back hook.
74SOLAS(20)II-2/9.4.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2024
Resolved
No electrical equipment shall be installed in any space
where flammable mixtures are liable to collect including
those on board tankers or in compartments assigned
principally to accumulator batteries, in paint locker
lockers, acetylene stores or similar spaces, unless the
Administration is satisfied that such equipment is:
appropriately certified for safe usage in the dusts,
vapours or gases likely to be encountered.
Vessel’s lighting fixture located outside the acetylene
and oxygen lockers was installed with inadequate
fittings (i.e. t-coupling, elbow, and nipples) that do
not meet the explosion proof requirements.
74SOLAS(04)II-1/45.10.4
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2024
Resolved
The Administration shall take appropriate steps to
ensure uniformity in the implementation and application
of the provisions of this part in respect of electrical
installations.
Cable gland and wiring to the deck water seal float
switch was installed with improper fittings and has
wiring exposed(i.e. t-glads, coupling,) that do not meet
the explosion proof requirements identified by the
International Electrotechnical Commission (IEC)
Publication 92.
74SOLAS(04)II-1/40.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 May 2024
Resolved
Electrical installations shall be such that: electrical
services essential for safety will be ensured under
various emergency conditions.
Multiple emergency lights were observed to be not
operational near embarkation areas for the lifeboat,
rescue boat, and liferafts.
74SOLAS(04)II-1/40.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 May 2024
Resolved
Before the ship leaves port and at all times during the
voyage, all life-saving appliances shall be in working
order and rady for immediate use.
The self contained air support system for the free fall
lifeboat had a broken gauge rendering it unreadable and
was leaking air into the boat at an uncontrollable rate.
74SOLAS(20)III/20.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2024
Resolved
Electrical installations shall be such that electrical
services essential for safety will be ensured under
various emergency conditions.
While testing the standby function for the no. 3 CFW
pump running in auto change mode, the pump was not able
to start up automatically.
74SOLAS(04)II-1/40.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Received report from ABS acknowledging the deficiency. Finding number 1007.0.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 July 2023
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. The main source of power shall consist of at east two generating sets.
Vessel reported failure of main circuit breakers for No.2 and No.3 main diesel generators. Vessel to conduct repairs to the satisfaction of RO.
74 SOLAS (41) II-1/41.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 May 2023
Resolved
Fire Protection systems and fire-fighting systems and
appliances shall be maintained ready for use.
Vessels water mist system indicating system fault
relating to the Pump Starter Motor.
74 SOLAS(08)II-2/14.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2023
Resolved
The machinery, boilers and other pressure vessels,
associated piping systems and fittings shall be of a
design and construction adequate for the service for
which they are intended.
Auxiliary boiler inoperable at time of inspection,
unable to complete testing of equipment.
74 SOLAS(08)II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 May 2023
Resolved
Illustrations and instructions in appropriate languages
shall be posted in passenger cabins and be conspicuously
displayed at muster stations and other passenger spaces
to inform passengers of: the method of donning
lifejackets.
Marine Inspector discovered missing lifejacket donning
instructions at lifeboat muster station.
74 SOLAS(20)III/8.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2023
Resolved
Waste receptacles shall be constructed of noncombustible
materials with no openings in the sides of
bottom.
Several wastes receptacles throughout the ship were made
of combustible materials(plastic).
74 SOLAS(08)II-2/4.4.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 May 2023
Resolved
Before the ship leaves port and at all times during the
voyage, all life-saving appliances shall be in working
order and ready for immediate use.
Ring buoy light located on the starboard cargo deck
handrail.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 May 2023
Resolved
All access openings in bulkheads at ends of enclosed
superstructures shall be fitted with doors that are
weathertight/watertight when closed.
Marine inspector noticed light coming through the
weathertight/watertight doors within the superstructure
when fully dogged down.
ILLC(98)Annex I Chapter
II/12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 May 2023
Resolved
The fire integrity of the divisions shall be maintained
at openings and penetrations.
Cable's penetrating fire divisions were incorrectly
installed inside cable trunk on “D” deck.
74 SOLAS(08)II-2/9.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 May 2023
Resolved
The fire resistance of doors shall be equivalent to that
of the division in which they are fitted.
Aft galley door that leads to dry stores cannot selfclose
or latch due to improper installation.
74 SOLAS(08)II-2/4.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 12 May 2023
Resolved
Protection of cargo tanks shall be achieved by a fixed
inert gas system in accordance with the Fire Safety
Systems Code(FSS) requiring the pressure of inert gas be
continuously indicated. Vessels Kongsberg inert gas
control screen is showing incorrect pressure readings
for NO.2 C.O.T(P).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 9 June 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 16 December 2022
Resolved
The inert gas system referred to in paragraph 5.5.3.1 shall be designed, constructed and tested in accordance with the Fire Safety System Code. In addition to the requirements of paragraph 2.2.4.5, audible and visual alarms shall be provided to indicate: low water pressure or low water flow rate to the cooling and scrubbing arrangement. The low pressure cooling water inlet alarm was inoperable.
705 A- Prior to cargo operations.
74 SOLAS (04) 11-2/4.5.5.3.2
FSSC/15.2.3.2.2.3
Action required: 705 - Other - as specified
Due 23 December 2022
Resolved 23 December 2022
Resolution: The low cooling water pressure alarm switch was replaced with new spare OEM switch. Upon completion low cooling water alarm and shut down was demonstrated in accordance with PSTP; additionally, operation of the Inert Gas Generator was demonstrated; sat.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 16 December 2022
Resolved
A general emergency alarm system complying with the requirements of paragraph 7.2.1 of the Code shall be provided and shall be used for summoning passengers and crew to muster stations and to initiate the actions included in the muster list. The system shall be supplemented by either a public address system complying with the requirements of 7.2.2 of the Code or other suitable means of communication. The public address system shall be a loudspeaker installation enabling the broadcast of messages into all spaces where crew members or passengers, or both, are normally present, and to muster stations. The public address system on the Fore Mast was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, public address speaker was reattached to the Fore Mast including wiring. Mounting arrangements were examined and the public address system operation was demonstrated and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. MI observed the Port and Starboard weathertight doors of the A-Deck will not dog down.
ICLL 88/16.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, crew adjusted the closing / dogging mechanism and operation was confirmed and sealing was demonstrated with chalk contact test and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Marine Inspector identified vent closure approximately 12” x 12” located on the bulkhead above and left of the Class I weathertight door for the Emergency Diesel Generator compartment with severely corroded/wasted knife edge for sealing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, sealing knife edge was repaired by weld build up, examined, operation was demonstrated and upon completion sealing was demonstrated with chalk contact test and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Marine Inspector identified knife edge on the Class I weathertight door for the Emergency Diesel Generator compartment that is corroded/wasted located on the bottom right of knife edge approximately 4” above the turn.
ICLL 88/16.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, sealing knife edge was repaired by weld build up, examined, operation was demonstrated and upon completion sealing was demonstrated with chalk contact test and considered satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2022
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such covers shall be weathertight and fitted with gasket and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. Marine Inspector identified Class I watertight door for the Emergency Diesel Generator compartment with missing/corroded metal track for gasketing.
ICLL 88/16.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 23 December 2022
Resolution: At this time, gasket retaining channel was repaired by cropping to fair and sound material and inserting the flat bar, examined, operation of the weathertight door was demonstrated and upon completion sealing was demonstrated with chalk contact test and
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 16 December 2022
Resolved
Every able seafarer deck serving on a seagoing ship of 500 GT or more shall be required to demonstrate the competence to perform the functions at the support level, as specified in column 1 of table A-II/5. The minimum knowledge, understanding and proficiency required of an able seafarer deck serving on a seagoing ship 500 GT or more is listed in column 2 of table A-II/5. The Ordinary Seaman handled lines during mooring operations without the proper STCW Endorsement (II/5). The vessel is appropriately manned with adequate personnel in accordance with the COI, however member should not have been utilized in the line handling position.
STCW Part A-II/5.1 and 5.2
Action required: 10 - Deficiency Rectified
Resolved 16 December 2022
Resolution: Master made aware of the OS's current endorsements and advised not to utilize member for line handling during mooring ops.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 16 December 2022
Resolved
All persons who are assigned duty as officer in charge of a watch or as a rating forming part of a watch and whose duties involve designated safety, prevention of pollution and security duties shall be provided with rest period of not less than a minimum of 10 hours of rest in any 24 hour period. Hours of rest shall be at least 6 hours in length. As per the vessel's system (Watchkeeping) the C/E on NOV 23, 2022 did not receive 10 hours of rest in the previous 24 hour period and did not receive the minimum 6 hour rest period.
STCW Part A-VIII/1.2 and 1.3
Action required: 10 - Deficiency Rectified
Resolved 16 December 2022
Resolution: Discrepancy noted per the SMS in vessel work/rest tracking system Watchkeeper.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 December 2022
Resolved
The machinery, boilers, and other pressure vessels associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards.
Marine Inspector identified the #2 Framo engine for the cargo pump fuel oil supply hose to the racor filter assembly is dry rotted. At the fitting at the racor assembly the hose is cracked. Engineers replaced hose and demonstrated proper operation of the engine with no leaks and no other concerns.
74 SOLAS (04) II-1/26.1
Action required: 10 - Deficiency Rectified
Resolved 16 December 2022
Resolution: Hose Replaced prior to completion of inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 31 May 2022
Resolved
74 SOLAS (14) IX/3.1
ISM Code 10.1
A 30
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. Master was unfamiliar with the contents of the vessel's SMS and unable to provide inspection reports, completed checklists for routine maintenance, or objective evidence that inspections and maintenance is being conducted to the watertight hatches and closures. Further, the Master was unable to locate SMS related material requiring assistance from the company in locating the SMS material. Due to the objective evidence in the below deficiencies, the vessel is not in
substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. An external audit conducted by the RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 1 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 31 May 2022
Resolved
ICLL (88) 16.1
A 30
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Such hatch covers shall be weather tight and fitted with gaskets and clamping devices. The arrangements shall ensure that the tightness can be maintained in any sea conditions. MI observed the watertight hatch for the Bosun space on the bow was not watertight. MI could feel air egressing from the space when dogged down. Crew conducted a hose test at 30 PSI which resulted in water ingress. MI observed the goose neck located at the Bow Centerline has irregularity on the knife edge preventing closure.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 31 May 2022
Resolved
ICLL (88) 19.4
A 30
Ventilator openings shall be provided with weather tight closing appliances of steel or other equivalent material. MI observed the natural ventilation mushroom head for the Bosun Store on the Starboard Bow is wasted and holed. MI observed the gasket for the power ventilation mushroom head for the Pant Stores wasted and corroded.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 June 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 May 2022
Resolved
74 SOLAS (04) II-1/
26.1
A 50
The machinery, boilers, and other pressure vessels associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The #1 Framo cargo pump fuel oil supply hose is dry rotted/ cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2022
Resolved
74 SOLAS (04) II-1/45.1.1
A 50
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. MI observed broken grounding wires on the Starboard side rescue boat muster station lighting. In addition, grounding wires to the controls of the Rescue Boat davit are corroded and broken. The power ventilation for paint and lamp stores has a disconnected ground wire. The tank heater locker power ventilation has a disconnected ground wire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 May 2022
Resolved
33 CFR 155.730
A 50
The vessel operator of each vessel required by § 155.720 to have transfer procedures shall maintain them current and shall require vessel personnel to use the transfer procedures for each transfer operation. Section 2, page 6 of vessel's transfer procedure requires " Top dead centerr of each flange bolt circle is a preventer pin designed to further identify these flanges as vapor recovery connections and not for the transfer of liquid cargo or ballast." Vapor recovery flange did not have a stud.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 31 May 2022
Resolved
74 SOLAS (14) III/ 20.2
C 10
Before the ship leaves port and at all times during the voyage, all life-saving appliance shall be in working order and ready for immediate use. MI observed the Port Bow embarkation ladder tie down strap was seized rendering it inoperable. In addition, securing shackles of the ladder were seized and unable to operate.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 31 May 2022
Resolved
74 SOLAS (14) II-2/ 10.4
10 C
Ships constructed before 1 JUL 2014 shall comply with the requirements of this paragraph not later than the first survey after 1 JUL 2018: a minimum of two-way portable communications radiotelegraph apparatus for each fire party for the fire-fighter's communication shall be carried on board.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 22 September 2021
Resolved
A food ration totaling not less than 10,000 kJ for each person the lifeboat is permitted to accomodate. The rations shall be packed in a permanently sealed or vaccuum packed in a flexible packaging material. 10 out of 32 food rations found on board the lifeboat have lost their vaccuum seal. Replace food rations with new rations.
SOLAS 74 (2020 Con. Ed.) III/13.1.4, LSA Code (2010) Ch. IV/4.4.8.12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 24 September 2021
Resolution: Referred to RO and received preliminary report for statutory condition to be rectified by 06OCT2021. Report attached under deficiencies/documents.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 September 2019
Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall comply with the following: The system shall be capable of being brought into operation from a position on the navigation bridge. Vessel experienced a non follow up of rudder on port steering pump. Provide transit plan and class report attesting to proper operation of steering system.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 September 2019
Resolved 11 September 2019
Resolution: Vessel provided class report attesting to proper operation of the steering system to the satisfaction of the attending marine inspector.