Records from 2010 to 2026. Most recent: inspection, 28 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
28 May 2026
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8434198
4 June 2025
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8162086
1 May 2025
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8126838
2 April 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8104129
14 August 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7981446
2 May 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7913572
24 August 2023
Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7776222
2 May 2023
Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection · Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7679467
5 December 2022
Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7604608
12 August 2022
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 7534874
16 May 2022
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7455023
25 April 2022
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7438805
28 July 2021
Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7271161
14 July 2021
Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7256512
27 April 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7188678
22 June 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7002233
22 April 2019
Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6667943
8 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6404307
10 May 2017
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6149662
24 April 2017
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6123875
16 July 2016
Type not recorded
No type recorded · USCGC MUSTANG (WPB 1310) · USCG Arctic District (CGD-A) · Activity 5943021
3 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5824435
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2025
Resolved
10109 - A power-driven vessel underway shall exhibit sidelights. The vessel's port side light had a burned out bulb. 33 CFR 83.23
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 June 2025
Resolution: Vessel replaced bulb and tested satisfactory
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 August 2024
Resolved
Ensure crew has completed a negative pre-employment test prior to serving in a safety sensitive position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 7 September 2024
Resolution: Rcvd objective evidence showing crew completed neg pre-employment test.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 August 2024
Resolved
Ensure fwd port and stbd fire dampers operate properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 25 September 2024
Resolution: operational test sat
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 August 2024
Resolved
Install interconnected fire detection that meets 46 CFR 181.450
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 25 September 2024
Resolution: cleared
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 August 2024
Resolved
Develop plan for handling and storing hazardous items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 25 September 2024
Resolution: cleared
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 August 2024
Resolved
Develop crew fire fighting and egress training and conduct monthly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 25 September 2024
Resolution: cleared
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 August 2024
Resolved
Ensure sufficient drills are conducted and logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 25 September 2024
Resolution: logged
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 May 2023
Resolved
All vessels must have the necessary navigation lights. The PORT nav-light is not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2023
Resolved 23 May 2023
Resolution: Corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 2 May 2023
Resolved
The vessel must comply with the all applicable FCC Radio requirements. The Radio Safety Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 26 June 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 May 2022
Resolved
Pre-engineered fixed gas fire extinguishing systems must be installed and maintained in accordance with the manufacturer's instructions. Found engine room fixed gas system discharged. Due to no availability of fixed gas system meeting full requirements, vessel granted authorization to temporarily install automatic release only system and to operate for not to exceed 21 days. Upon receiving new fire system meeting regulation requirements, operator is to provide proof of proper installation to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2022
Resolved 2 August 2022
Resolution: Inspected and tested: ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2022
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station. Port engine room bilge high level audible alarm in-op. Repair and demonstrate proper operation to attending CG-MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2022
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 May 2022
Resolved
Each window, port hole, and its means of attachment must be capable of withstanding the maximum load from wave and wind conditions expected. Repair as original cracked window on stbd side, middle of cabin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 8 June 2022
Resolution: Window replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2022
Resolved
Main propulsion engines were replaced (exact/in-kind replacements). Demonstrate proper operation of engines while underway.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2022
Resolution: Witnessed sat op test of main engines.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 16 May 2022
Resolved
Unable to get underway for drills during COI. Demonstrate satisfactory fire and M.O.B. drills to the satisfaction of the attending CG-MI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2022
Resolution: Witnessed satisfactory fire and MOB drills.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 April 2022
Resolved
Liferaft 02 locations needed to be re-glued
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 25 April 2022
Resolved 25 April 2022
Resolution: repairs made by Eagle tech
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 July 2021
Resolved
Missing 02 night flares; several found expired. Currently has 4 hand red flares and 6 hand orange smoke flares.
Action required: 10 - Deficiency Rectified
Resolved 14 July 2021
Resolution: Owner purchased new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 July 2021
Resolved
Liferaft painter line was attached to cradle. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 14 July 2021
Resolution: Training was conducted with the crew about how to properly install the liferaft and painter was properly reattached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2021
Resolved
Ring life buoy light battery is expired and line is wasted. Renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2021
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 July 2021
Resolved
Drill and EPIRB testing has not been documented for the 2021 season. Conducted drill and EPIRB testing; all sat.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2021
Resolved
Missing 01 fire bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
Fuel fitting for port and starboard tanks were found corroded. Renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2022
Resolved 5 December 2022
Resolution: The vessel received a satisfactory USCG inspection since the deficiency was originally issued.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 July 2021
Resolved
Starboard bilge high water alarm electrical line is cut and corroded. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2021
Resolved
Ensure electrical wiring in port engine room is stored and mounted. Currently excessive wiring could cause snag hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 July 2021
Resolved
Vessel is currently taking on a slow, steady amount of water in the port engine room. Determine source and repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2021
Resolution: Cleared by MSD Homer
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 June 2020
Resolved
Expired medicine found in first aid kit. Update.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 22 July 2020
Resolution: first aid kit updated
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2020
Resolved
Lanyards missing on firebuckets. Provide three approved fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 22 July 2020
Resolution: fire buckets had lanyards
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 June 2020
Resolved
Ensure child PFDs are stowed separately from aldult PFDs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 22 July 2020
Resolution: PFDs stowed separately
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 June 2020
Resolved
Electrical wire was installed through engine room ventilation preventing proper operation of the fire damper. Ensure proper operation of the port and starboard aft engine room damper.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2020
Resolved 22 July 2020
Resolution: Electrical wiring rerouted. Operation of dampers sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 June 2020
Resolved
Painter line on liferaft was found connected to the vessel. Vessel rep properly connected painter line.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2020
Resolution: Corrected on the spot.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 May 2018
Resolved
Replace alcohol test strips. Existring test strips are expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 6 June 2018
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 May 2018
Resolved
Install proper machine guards around belts on both engines. Belts are not sufficiently guarded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 6 June 2018
Resolution: Verified installation of proper machine guards //s// [name withheld]
Stability › Weathertight Integrity › General
Issued 23 May 2018
Resolved
Replaced cracked windows on port side cabin and pilot house with appropriate safety glazing materials. 46 CFR 177.1010
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 6 June 2018
Resolution: Verified installation of appropriate safety glazing. //s// [name withheld]
Lifesaving › Lifebuoys › Serviceable
Issued 23 May 2018
Resolved
Replace lifering. Existing lifering is not in suitable condition - grab line is frayed, paint is peeling and cracked and suceptible to water damage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 6 June 2018
Resolution: verified installation of serviceable lifering. //s// [name withheld]
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 23 May 2018
Resolved
Post emergency instructions placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 6 June 2018
Resolution: Verified installation of emergency instructions placard. //s// [name withheld]
Communications › Audible Communications › Horn/Whistle
Issued 10 May 2017
Resolved
Provide proper operation of ships whistle.
Due 11 May 2017
Resolved 10 May 2017
Resolution: Verified operation of ship's whistle.
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 May 2017
Resolved
Provide current Coast Pilot
Due 11 May 2017
Resolved 10 May 2017
Resolution: Verified provision of Coast Pilot
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 May 2017
Resolved
Provide current light list.
Due 11 May 2017
Resolved 10 May 2017
Resolution: Verified provision of light list.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 May 2017
Resolved
Have fixed system serviced by licensed state individual with IIIA or IIIB endorsement.
Due 11 May 2017
Resolved 10 May 2017
Resolution: Verified licensing of fire systems inspector.
Lifesaving › Hand Flares › Not on Board
Issued 24 April 2017
Resolved
Provide six red flares.
Due 11 May 2017
Resolved 10 May 2017
Resolution: Verified provision of flares.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 April 2017
Resolved
Provide alcohol test strips. Vessel liimited to no more than 2 hours from port until cleared.
Due 11 May 2017
Resolved 10 May 2017
Resolution: Verified provision of alcohol testing equipment.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2016
Resolved
Provide updated charts and publications
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 26 May 2016
Resolution: Current charts and pubs onboard.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 3 May 2016
Resolved
Provide hydrostatic release for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2016
Resolution: a new hydrostatic release was installed
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 3 May 2016
Resolved
Provide 6 orange smoke distress signals
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2016
Resolution: Required flares are now onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2016
Resolved
Replace expired first aid contents
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 5 May 2016
Resolution: Required first aid kit contents are now onboard.