← All vessels
NOVI
NOVI is a 2007 tank barge. The Coast Guard has recorded 22 inspections since 2006, most recently in May 2026, along with 16 deficiencies.
Records from 2006 to 2026. Most recent: inspection, 5 May 2026.
- Built
- 2007
- Last inspected
- 5 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1197922
NONE
878920
Flag
UNITED STATES
—
Maury page id
psix-878920
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)150.0 ft × 40.0 ft × 6.0 ft
Registered tonnagegross 302 / net 302
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEOUFWAY CONTRACTORS LLC · HOUMA, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNENANA, AK
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 16 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it302 - Simplified, Gross Ton
302 - Simplified, Net Ton
302 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
5 May 2026
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8314633
8 May 2025
Periodic Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8118221
9 May 2024
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7918830
8 May 2023
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7685965
11 May 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7444092
12 May 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7201535
28 April 2020
Annual Inspection · Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7018466
9 May 2019
MTSA Verification · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6678909
8 May 2018
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6410499
10 May 2017
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6162666
10 May 2016
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5983333
11 May 2015
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5122948
14 October 2014
Cargo Tank Internal · Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5007013
12 May 2014
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4864499
14 June 2013
MTSA Verification · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4616877
7 May 2012
COI Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4301592
11 May 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3769308
13 May 2009
Periodic Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3507427
20 May 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3212951
16 September 2007
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3060088
12 September 2007
Deficiency Check · MTSA Verification · In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3056160
14 November 2006
Welding Related Inspections Qualification Testing · Initial Certification · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2820371
Deficiency record · 16
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 May 2023
Resolved
In hazardous areas machinery and electrical equipment must be approved for the installation by MSC. The diesel engine with associated electrical components that drives the cargo pump must be approved for operation within the hazardous zone or place the engine and electrical components outside the hazardous zone (10 ft). Any modification or equipment changes must be approved by the OCMI and/or MSC.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2023
Resolved
Provide a Hazardous location plan with all required information as required by 46 CFR 110.25-1(i) to MSC for approval.
Construction/Loadline › Hull › Side Shell
Issued 16 September 2007
Resolved
Barge restricted from loading following discharge of present cargo. Submit repair proposal and complete permanent repairs prior to carrying further cargoes. Obtain certified gas-free marine chemist certificate for affected cargo tank & adjacent voids and/or cargo tanks & make barge available to Coast Guard marine inspector.
Stability › Incline Test › General
Issued 31 May 2007
Resolved
Provide stability letter prior to carraige of cargo.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 31 May 2007
Resolved
Provide original COFR prior to operation.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 May 2007
Resolved
Provide original COD.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 31 May 2007
Resolved
Provide transfer procedures and piping diagram prior to operation.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 31 May 2007
Resolved
Provide fuel shut-off valves at prime mover and fuel tank.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 31 May 2007
Resolved
Vent too small. Install larger vent with screen.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Adapters
Issued 31 May 2007
Resolved
Provide blanks and gaskets for manifold ends.
Communications › Visual Communication › Red Warning Signal
Issued 31 May 2007
Resolved
Provide red flag.
Communications › Visual Communication › Warning Sign (gangway)
Issued 31 May 2007
Resolved
Install warning sign - Danger, no visitors, no open lights, etc.
Communications › Visual Communication › Warning Sign (gangway)
Issued 31 May 2007
Resolved
Provide MTSA restricted area sign.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 31 May 2007
Resolved
Provide flame screens for guaging openings.
Engineering › Fuel Oil Service System › Hose
Issued 31 May 2007
Resolved
Provide correct flexible hoses and fittings.
Pollution Prevention/Response › Response Equipment › Containers
Issued 31 May 2007
Resolved
Provide spill kit.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.