MAURY USCG vessel records Sign in
← All vessels

THAT'S RIGHT

THAT'S RIGHT is a 2007 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2007, most recently in April 2026, along with 77 deficiencies, 1 operational control and 2 casualty investigations between 2014 and 2017.

Records from 2007 to 2026. Most recent: inspection, 7 April 2026.

Built
2007
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG7365
878939
Flag
UNITED STATES
368303850
Maury page id
psix-878939

Inspections, by type

…with no type recorded3
Years with a record 17 calendar years (2007–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVANS BOAT REPAIR INC · CRISFIELD, MD, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOCEAN CITY, MD
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 8 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN6940MMSI 368303850 · active · compulsorily equipped · granted 23 March 2023, expires 23 March 2033 · licensed under a name not among this hull’s recorded names (not shown)
WDG7365MMSI 367566540 · expired · voluntarily equipped · granted 16 March 2013, cancelled 20 May 2023
WDD6942MMSI 367179760 · expired · compulsorily equipped · granted 12 April 2007, cancelled 17 June 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MATADOR Passenger (Uninspected) · MISLE 131270 · 28 June 2014 · activity 4906451

Inspection history · 28

7 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8345192
5 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8133071
8 April 2025 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8085224
13 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7912656
10 May 2023 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7685060
26 April 2023 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7676008
11 March 2022 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7410211
12 May 2021 DAPI Audit · Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7195489
7 April 2021 Examination of Repairs · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7170464
27 April 2020 DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6946057
21 March 2019 Hull Examination · Annual Inspection · Administrative Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6646444
25 May 2018 DAPI Audit · Internal Structural Exam · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6595734
27 March 2018 Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6379286
26 March 2018 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6378616
9 May 2017 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6142447
5 April 2017 Internal Structural Exam · COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6118080
5 March 2017 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6147356
13 April 2016 Administrative Inspection · Drydock Exam · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5840651
29 October 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5010000
28 June 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4906451
20 May 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4858749
2 December 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4226151
24 February 2010 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3685529
27 April 2009 Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3461964
9 June 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3231842
2 June 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3226142
21 May 2008 Type not recorded
No type recorded · Station Hobucken · USCG East District (CGD-E) · Activity 3216249
13 December 2007 In-Service Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3114757

Deficiency record · 77

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 April 2026 Resolved
03 Fire buckets are missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2026
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 April 2026 Resolved
EPIRB monthly tests need to be logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2026 Resolved
03 life jackets need working lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2025 Resolved
Alcohol awsabs have expired. Purchase new swabs from consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 7 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2025 Resolved
06 life jackets need to have light since the vessel has a oceans route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 7 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2025 Resolved
05 lifejackets need to have new retro tape place on them.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2025
Resolved 7 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2024 Resolved
All 12 flares had expired April 2024. Must replace all 12 flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2024 Resolved
3 of the 5 high water alarm visual indicators (lights) were not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2024 Resolved
Stern light was not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector. Vessel is limited to Day light hours only until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2024 Resolved
First aid kit had some expired items. Must replace all expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2024 Resolved
FCC Safety Certificate expired May 2023. Must show proof of valid FCC Safety Certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 14 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2023 Resolved
12 life jacket lights were not working. Replace batteries or lights and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2023
Resolved 22 May 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2023 Resolved
First aid kit had expired Aspirin. Must replace with new Aspirin.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2023
Resolved 22 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 May 2023 Resolved
Emergency fuel shut off valves and ventilation closures needs labeling.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2023
Resolved 22 May 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2022 Resolved
Stern NAV light and mast/anchor light were not working. Also mast/anchor light was obstructed from a 360 degree view due to camera and radar. Make repairs and raise mast/anchor light additionall 3 feet prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2022
Resolution: Installed new 3 foot anchor/mast light. Test SAT
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 April 2022 Resolved
Captain is missing his FCC operators permit. Must show proof of FCC operators permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 6 April 2022
Resolution: Captain received his FCC operators permit
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 April 2022 Resolved
Bilge high water alarm visual indicator did not work. Audible and pump worked. Must make repairs and test visual indicator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 26 April 2022
Resolution: Replaced light, test SAT
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 April 2022 Resolved
Missing EAP info. Must post EAP info with hotline numbers where all crew have access.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 11 April 2022
Resolution: Recieved pictures showing EAP stuff posted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2021 Resolved
Vessels portable fire extinguishers require annual servicing. Existing portable fire extinguishers were past their annual inspection/service dates.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2021
Resolution: Attending Inspector(s) verified annual servicing of portable fire extinguishers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 May 2021 Resolved
Vessels crew required to be enrolled in an approved chemical testing program (46 CFR Part 16). Vessels deckhand/crew was not properly enrolled in the marine employers drug testing consortium.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 May 2021
Resolution: Attending Inspector(s) verified crewmembers enrollment in an approved consortium.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 May 2021 Resolved
Vessels COI is assigned to vessel outlining routes/conditions of operation. Vessels existing COI does not reflect passenger operations in South Carolina or Georgia. Vessel intends to carry passengers for hire between [name withheld] South Carolina and Miami, FL.
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 14 May 2021
Resolution: Vessels COI was fixed May 2021
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 April 2021 Resolved
Fireboy system is not working properly. Engines will shut down, but loses power to controls and unable to start engines in overide mode. Must make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 12 April 2021
Resolution: Replaced overide switch, Tested SAT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2021 Resolved
Mast and stern NAV lights not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers. COLREGS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 8 April 2021
Resolution: Bad connection, replaced conectors. Test SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 April 2021 Resolved
Bow hatch is broken and unable to meet watertight integrity requirements. Must replace hatch to the satisfaction of attending CG Marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2021
Resolved 8 April 2021
Resolution: Installed brand new hatch. All SAT
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 April 2021 Resolved
3 of the 5 bilge high water alarms indicators do not work at the operating station. All audible alarms and bilge pumps do work. Must make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 April 2021 Resolved
First aid kit was found to have several expired items. Must replace all expired items and make first aid kit meet the requirements of 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 20 April 2021
Resolution: Bought new first aid kit that met the requirements for 46 CFR 160.041
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 April 2021 Resolved
Alcohol swabs were expired and only had 2 onboard. Must replace and have minimum 3 to cover all crew onboard in case of emergency.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 12 April 2021
Resolution: Received new alcohol swaps. Expire April 2022, all SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2020 Resolved
Bilge pump system is inoperable. Repair/Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2020
Resolution: Bilge pump system was repaired and correct operations were verified.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 April 2020 Resolved
Vessel has 3 flares that are expired. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2020
Resolution: 3 flares were purchased and verified on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2020 Resolved
Life ring buoy and float line must be renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2020
Resolution: Life ring buoy and float line was renewed with authorized equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 27 April 2020 Resolved
New IBA must be installed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2020
Resolution: New Revere 25 person IBA replaced the life floats.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 April 2020 Resolved
Prove proper operation of VHF.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2020
Resolution: VHF were verified to be in proper operational condition.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 21 March 2019 Resolved
Fire boy over ride does not allow restart.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2019
Resolution: Entire fireboy unit was replaced. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 March 2019 Resolved
Bilge high level visual alarm is extinguished. Repair.
Action required: 705 - Other - as specified
Resolved 6 May 2019
Resolution: All bilge alarms and lights have been overhauled and tested All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 March 2019 Resolved
V-Berth bilge auto operation light is extinguished.
Action required: 705 - Other - as specified
Resolved 6 May 2019
Resolution: All bilge pumps and alarms have been rebuilt and tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 March 2019 Resolved
Lanyard for life ring strobe is wasted. Renew.
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Renewed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 March 2019 Resolved
Stern light is extinguished.
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 March 2019 Resolved
Repaint life float on STBD side, and renew reflective tape.
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Renewed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2019 Resolved
Renew alcohol swabs
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Renewed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 March 2019 Resolved
Build new book for drug program.
Action required: 705 - Other - as specified
Resolved 6 May 2019
Resolution: New drug program was built and verified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 May 2018 Resolved
pre engineered fire system does not secure the engines when it is activated. Repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2018
Resolution: System was repaired, and tested all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2018 Resolved
Electrical connection for refrigerator is not mounted or enclosed. Mount and enclose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Electrical connection was properly mounted and enclosed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 May 2018 Resolved
lanyard between life floats is worn and must be renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 May 2018 Resolved
Life floats are not attached to the vessel with a weak link. Both floats must be attached to the vessel via a weak link and painter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: New painter basket with weak link was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2018 Resolved
Life float must be marked with max capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Life float was marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2018 Resolved
Life float must have 2 paddles per float. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Paddles were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2018 Resolved
Multiple PFD lights are not operating. Repair/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: New lights were provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 May 2018 Resolved
FCC safety radio certificate is expired. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: Certificate was renewed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 May 2018 Resolved
Vessel logs do not provide for life saving maintenance tracking and EPIRB testing. Provide new log.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2018
Resolution: New log was provided and will be used to track EPIRB and life saving tests/maintenance.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 27 March 2018 Resolved
BATTERY FOR GENERATOR MUST BE ENCLOSED IN BOX
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2018
Resolved 30 March 2018
Resolution: Battery was placed in an off the shelf battery box.
Communications › Radio Communications › EPIRB
Issued 5 April 2017 Resolved
EPIRB battery is expired, repair/replace
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2017
Resolution: New EPIRB was purchased and registered prior to completeion of the exam.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2017 Resolved
Fuel tank space bilge high level Lrm is inoperable. Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2017
Resolution: Several wires in the bilge system had been pulled loose. O/O repaired wires and tested sat prior to the completeion of the inspection.
Lifesaving › Hand Flares › Quantity
Issued 5 April 2017 Resolved
Vessel was missing 2 red hand flares. Replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2017
Resolution: New flares were purchased and placed onboard, prior to the completeion of the inspection.
Communications › Audible Communications › SPD (Other)
Issued 5 April 2017 Resolved
Vessel horn is inoperable.Replace/repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2017
Resolution: New hand held horn was purchased while horn is being repaired. Cleared prior to completeion of inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2017 Resolved
Vberth and engine room visual alarm lights are extinguished. repair/renew.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 20 April 2017
Resolution: lights were repaired and tested, all sat.
Engineering › Fuel Oil Service System › Filter
Issued 5 April 2017 Resolved
Racor filter is missingthe flame bowl. Repair/renew.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 20 April 2017
Resolution: Flame bowl was purchased from RACOR, and installed. SAT.
Engineering › Fuel Oil Service System › Valve
Issued 5 April 2017 Resolved
Remote fuel valves are not marked. Mark per CFR.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 20 April 2017
Resolution: Valves were properly marked.
Lifesaving › Lifebuoys › Stowage
Issued 5 April 2017 Resolved
Life ring does not have a 3-6 ft lanyard attached to the strobe. Provide.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 20 April 2017
Resolution: Lanyard was provided with a non-corrosive clip.
Lifesaving › Lifebuoys › Serviceable
Issued 5 April 2017 Resolved
Retro tape on ring is wasted, repair/replace.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 10 May 2017
Resolution: New reflective tape was installed.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 5 April 2017 Resolved
Vessel does not have emergency instructions list. Provide and post.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 10 May 2017
Resolution: Emergency instructions were posted.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 April 2017 Resolved
Compass light is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 10 May 2017
Resolution: Light was replaced and tested all sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 April 2017 Resolved
Navigation Publications are expired and must be updated.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 10 May 2017
Resolution: New publications were provided.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2017 Resolved
Life folat strobes had wrong batteries installed and were therefore too heavey to float. Replace batteries or renew strobes.
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 10 May 2017
Resolution: Correct batteries were installed and tested. All Sat.
Communications › Alarms/Indicators › High Water Alarm
Issued 13 April 2016 Resolved
Prove proper operation of all bilge alarms and indicators.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2016
Resolved 28 April 2016
Lifesaving › Buoyant Apparatus › Pendant
Issued 13 April 2016 Resolved
Provide new pendants for life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 May 2014 Resolved
prove proper operation of all bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Lifesaving › Hand Flares › Expired
Issued 20 May 2014 Resolved
Provide new flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 May 2014 Resolved
Provide new life line for ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 December 2011 Resolved
Vessel operator does not have comprehensive drug and alcohol program, all crew members are enrolled in drug consortium. No company policy, no back ground checks, no record keeping. Bring drug and alcohol program in compliance with all applicable regulations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 January 2012
Resolved 22 December 2011
Resolution: New drug and alcohol program installed. All sat.
Lifesaving › Lifefloat › Serviceable
Issued 2 December 2011 Resolved
Repair small holes in foam cover, and repaint entire Lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 January 2012
Resolved 22 December 2011
Resolution: Lifefloat all sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 December 2011 Resolved
Stencil remote fuel shut off location on deck above fuel valves.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 January 2012
Resolved 22 December 2011
Resolution: New stencil on deck to indicate fuel valves location.
Communications › Radio Communications › EPIRB
Issued 2 December 2011 Resolved
EPIRB hydrostatic release expired on December 8, 2008. Renew hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2011
Resolution: New hydrostatic release installed.
Communications › Radio Communications › EPIRB
Issued 2 December 2011 Resolved
EPIRB battery expired on March 2011. Renew EPIRB battery.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2011
Resolution: New battery installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 December 2011 Resolved
Guard for Starboard MDE belts and pulleys is missing. Provide proper guard for engine pulleys.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 January 2012
Resolved 22 December 2011
Resolution: New belt guard installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 April 2009 Resolved
Conduct credit drydock exam IAW 46 CFR 176.600(c)(1). Vessel's due date was 31MAR2009.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2009
Resolved 28 April 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 June 2008 Resolved
Mast light could not be examined due to damaged mast. Prove proper operation of mast light IAW 46 CFR 183.420.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 9 June 2008
Resolution: Proved proper operation of mast light.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 June 2008 Resolved
Provide proof of servicing for portable fire extinguishers and fixed fire extinguishing system IAW 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 9 June 2008
Resolution: Provided proof of servicing for portable fire extinguishers and fixed fire extinguishing system.

Casualty record · 2

28 June 2014Routine · role: Transiting Vicinity of Primary Subject · activity 4906451
5 March 2017Routine · role: Involved in a Marine Casualty · activity 6147356
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.