Records from 2016 to 2026. Most recent: inspection, 19 July 2026.
Inspection history · 22
19 July 2026
Type not recorded
No type recorded · Station Point Judith · USCG Northeast District (CGD-NE) · Activity 8442260
30 May 2025
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8146610
13 May 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8135295
11 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7922551
29 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7897026
15 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7703410
8 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7674382
5 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7483893
8 April 2022
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7415756
29 August 2021
Type not recorded
No type recorded · Station Point Judith · USCG Northeast District (CGD-NE) · Activity 7299485
29 August 2021
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7299533
29 August 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7301246
19 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7239100
2 June 2020
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6957053
12 May 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6945511
4 June 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6689443
29 April 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6663366
12 June 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6431309
17 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6388698
8 June 2017
Internal Structural Exam · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6160180
13 May 2016
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5868693
26 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5848350
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2025
Resolved
The float-free link required by § 180.130(a)(1) must be:(1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant;(2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag;
Float free link was found oversized for the installed liferaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 May 2025
Resolved
On each ring life buoy on a vessel all exposed materials must be resistant to oil or oil products, salt water and anticipated weather conditions encountered at sea. Life buoy plug has deteriorated and internal foam is retaining seawater.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 June 2024
Resolved
Each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel. live well valves are removed and need to be reinstalled w/in 7 days.
Action required: 705 - Other - as specified
Due 18 June 2024
Resolved 17 June 2024
Resolution: Received evidence of valves installed as designed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 June 2023
Resolved
Master of vessel shall keep written count of all passengers in accordance with this Subpart and make count available to CG on request. Dock box for list was missing/damaged would not hold list. Replace prior to ops.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2023
Resolved 23 June 2023
Resolution: replaced dock box for pax count
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 June 2023
Resolved
As appropriate for voyage vessel should have up to date charts. Paper chart of operating area was over 3yrs old with no corrections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2023
Resolved 24 July 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 21 June 2023
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Deckhand did not show for work, vessel not able to get underway and conduct drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2023
Resolved 24 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 June 2023
Resolved
§ 181.450 Interconnected detection and alarm system. Vessel did not have interconnected detection system, Oceans route. Vessel restricted to NMT 20 NM from a harbor of safe refuge.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2023
Resolved 24 July 2023
Resolution: installed new ul217 detectors interconnected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 June 2023
Resolved
A vessel of less than 65ft must be equipped with 1 fixed power pump and one portable pump. Portable bilge pump dryrotted, not fully operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2023
Resolved 23 June 2023
Resolution: bought new hand pump
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 July 2022
Resolved
Each item of lifesaving equipment determined to not be in serviceable condition must be repaired. Lifefloat mounted on pilothouse is worn and must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2022
Resolved 1 September 2022
Resolution: Completed life float repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 July 2022
Resolved
Rails must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Rails on the port and stbd side of the aft deck are loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2022
Resolved 9 August 2022
Resolution: Rails have been tightened on the aft deck.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 July 2022
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents. Medicine in the kit is expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2022
Resolved 9 August 2022
Resolution: Obtained a new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 July 2022
Resolved
The EPIRB test required to be conducted monthly shall be logged or otherwise documented. EPIRB tests are not logged.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 July 2022
Resolution: Will log EPIRB tests with drills.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 August 2021
Resolved
henever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel collided with the recreational vessel JAMIE MARIE. Prior to operating a Coast Guard Marine Inspector must complete a survey of the vessel to determine extent of damage.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2021
Resolution: See Activity Number 7299533
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 July 2021
Resolved
A vessel must carry up-to-date U.S. Coast pilot. Provide updated Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 16 August 2021
Resolution: New U.S. Coast Pilot on board. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 July 2021
Resolved
A vessel must carry a first-aid kit. First-aid kit has expired content. Provide kit with updated content.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2021
Resolved 16 August 2021
Resolution: Aspirin procured. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 July 2021
Resolved
The master must ensure that each EPIRB is tested monthly. The test must be logged. EPIRB test have not been conducted or logged.
Action required: 10 - Deficiency Rectified
Resolved 19 July 2021
Resolution: EPIRB test conducted and logged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2021
Resolved
Each life buoy must be marked in block letters with the vessel's name. Buoy not marked.
Action required: 10 - Deficiency Rectified
Resolved 19 July 2021
Resolution: Life buoy marked. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 July 2021
Resolved
The master shall conduct sufficient drills to make sure crew members are familiar with their duties. Drills not being conducted and not being logged per regulations.
Action required: 10 - Deficiency Rectified
Resolved 16 August 2021
Resolution: Conducted/discussed drills and ensured drills were logged. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 June 2020
Resolved
Provide updated charts and publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2020
Resolved 8 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 June 2020
Resolved
Provide alcohol test strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2020
Resolved 18 August 2020
Resolution: Updated alcohol test strips
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 2 June 2020
Resolved
15 man lifefloat no longer in servicable condition. Vessel restricted to total 8 persons.
Action required: 705 - Other - as specified
Due 2 June 2020
Resolved 17 August 2020
Resolution: 15-man lifefloat replaced with 8-man lifefloat
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 June 2020
Resolved
Provide new log book for vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2020
Resolved 8 June 2020
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 June 2018
Resolved
Provide proof of enrollment in DAPI program for all crewmembers.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 26 June 2018
Resolution: Provided proof of enrollment in DAPI program for all crewmembers.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 June 2018
Resolved
Replace expired alcohol test kits.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2018
Resolved 12 June 2018
Resolution: Replaced expired alcohol test kits.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 June 2017
Resolved
Annual servicing report not completed, scheduled asap.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 12 June 2017
Resolution: Servicing report completed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 June 2017
Resolved
expired aspirin in First aid kit.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 12 June 2017
Resolution: Purchased and replaced aspirin in first aid kit.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 June 2017
Resolved
Found wire lugs used E/R, put in box closure or connect in light assembly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 12 June 2017
Resolution: Light fixture properly wired.
Engineering › Steering Gear System › Valve
Issued 8 June 2017
Resolved
Found drain valve missing plug / cap.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 12 June 2017
Resolution: Barb on drain removed and plug installed.
Communications › Radio Communications › EPIRB
Issued 13 May 2016
Resolved
Replace expired hydrostatic release on EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2016
Resolved 16 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 13 May 2016
Resolved
Hook up VHF radio to receive GPS position
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 16 June 2016
Lifesaving › Lifefloat › Markings
Issued 13 May 2016
Resolved
Properly mark lifefloats with vessel name and official number.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 16 June 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 May 2016
Resolved
Ammend markings on lifejacket bins.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 16 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2016
Resolved
Replace expired ammonia inhalents
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 16 June 2016