SUNNY LAKES is a 2007 tank ship. The Coast Guard has recorded 36 inspections since 2016, most recently in November 2025, along with 6 deficiencies and 3 operational controls.
Records from 2016 to 2025. Most recent: inspection, 30 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it12776 - Convention (Subpart B), Gross Ton 6673 - Convention (Subpart B), Net Ton 20540 - Dead Weight, Metric Ton 27456 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 36
30 November 2025PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8275168
21 August 2025Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8215296
26 September 2024COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8009561
22 February 2024Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7869191
19 January 2024PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7851703
18 September 2023Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7793577
7 August 2023Administrative Inspection · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7762422
20 January 2023PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7624352
1 February 2022Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7389370
13 January 2022COC-CHEM & TVE Renew
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7379767
31 May 2021Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7211131
1 February 2021PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7132297
18 December 2020PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7113825
17 November 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7094599
28 September 2020Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7066844
25 September 2020Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7065385
16 June 2020Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6978033
28 February 2020Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6917454
30 January 2020PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6899286
19 November 2019MARPOL Annex II Examination · Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6857755
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 7 August 2023Resolved
Whenever a defect is discovered which effects equipment covered by the Code, the Master shall report to the RO responsible for issuing the Certificate and PSC Authorities; Vessel's 3P Framo pump stopped working. Vessel is authorized to utilize portable cargo pump for discharge IAW P&A Manual and Risk Assessment.
Vessel is not authorized to replace Framo pump until Flag and Class have approved procedures. Prewash will not be completed prior to departure IAW MARPOL Annex II 13.4.3
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2023
Resolution: Vessel conducted maintenance on pump and was able to clear the deficiency without replacing or using spare parts.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 February 2021Resolved
Before the Ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. [name withheld]3d outboard engine on rescue boat stuck in full throttle forward. Engine was unable to return to nuetral. 17 a,c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: The ship received replacement spare parts and installed them. Upon our arrival we tested the opertion of the rescue boat fully in ahead and astern directions as well as full throttle and find repairs acceptable. The outboard motor is working as designed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 March 2019Resolved
There shall be at least one portable foam applicator unit complying to the FSS Code. A portable foam applicator unit shall contain at least 20 liters of foam concentrate and at least one spare tank of foam concentrate of the same capacity. Portable foam applicator unit near generator #2 was not provided with a spare tank of foam concentrate. 74SOLAS(14) II-2/10.5.2.2.1 Ref FSS Code 4.3.2.1. 16ac.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2019
Resolved 12 May 2019
Resolution: Additional spare foam concentrate tank has been provided and placed in vicinity of
applicator. Class report uploaded.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 March 2019Resolved
A chemical tanker shall comply with the requirements of the IBC Code. Cargo tanks shall be fitted with visual and audible high level and tank over-flow alarms. Audible alarm for high level and tank overflow was inoperable. 74SOLAS(14) VII/10.1 Ref IBC Code 15.19.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 March 2019
Resolution: Siren's supply of ship service air had been cut off for maintenance. Ship service air supply was re-engaged and the alarm was observed to be in proper working condition.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 23 July 2018Resolved
0799- The inert gas system shall be capable of inerting, purging, and gas-freeing empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen content. PSCO observed the calibration gas for the inert gas generator was expired and crew was unable to prove accurate nitrogen purity levels. Correct prior to carrying cargoes requiring inert gas as required. 74SOLAS(04) II-2/Reg.4.5.5.3.1
Action Taken 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2018
Resolution: VESSEL HAS RECEIVED AND INSTALLED CAL GAS.
Fuel pumps can not generate enough pressure to start main engine in reverse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 14 November 2016
Resolution: Fuel pumps were rebuilt while the vessel was moored in Hamilton, Ontario, Canada.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.