Records in 2016. Most recent: operational control imposed, 9 May 2016.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 May 2016
No resolution recorded
1510 - Navigation equipment - All ships 3,000 gross tons and upwards shall have a 3 GHz radar or, where considered appropriate by the Administration, a second 9 GHz radar. PSCO observed while on board the vessel the 3 GHz radar was inoperable. 74 SOLAS (14 CON) CH. V Reg. 19.2.6
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 May 2016 — due date passed with no resolution recorded
Construction/Loadline › Markings › Load Line Mark
Issued 6 May 2016
No resolution recorded
1220 - Load Lines - The ring, lines, and letters shall be painted in white or yellow on a dark ground or in black, on a light ground. PSCO observed that the load line was not painted on the hull. ICLL Reg. 8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2016 — due date passed with no resolution recorded
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 6 May 2016
Resolved
2560 - ISM related - Significant evidence was discovered during an expanded machinery exam revealing the company/vessel failed to implement all applicable requirements of the Safety Management System (SMS) by not verifying appropriate corrective action was taken. Request an external audit of the vessels SMS. 74 SOLAS(14 CON) IX/ 3.1 ISM Code Reg. 5, Part A Reg.1.4,Reg.2.2,Reg.3,Reg.5,Reg.9,Reg.10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2016
Resolved 9 May 2016
Resolution: Coast Guard attended vessel and determined that deficiency was rectified satisfactorily.
Engineering › Steering Gear System › Power Unit
Issued 6 May 2016
Resolved
0936 - Safety in General - Means shall be provided to control leaks of flammable liquids. PSCO observed, during the steering gear test, oil spewing out of the lube oil pressure gauge for the #2 pump at a rate of approximately a quart every ten seconds. 74 SOLAS (09 CON) CH. II-2 Reg. 4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2016
Resolved 9 May 2016
Resolution: Coast Guard attended vessel and determined that deficiency was rectified satisfactorily.
Engineering › Lubricating Oil Service System › Piping
Issued 6 May 2016
Resolved
0999 - Safety in General - Means shall be provided to control leaks of flammable liquids. PSCO observed a half full bucket of lube oil on two main generators. Buckets were capturing lube oil spilling from an unidentifiable source. PSCO observed large quantities of oil splashed over both generators. 74SOLAS (09 CON) CH. II-2 Reg. 4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2016
Resolved 9 May 2016
Resolution: Coast Guard attended vessel and determined that deficiency was rectified satisfactorily.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 6 May 2016
Resolved
0799 - Fire Fighting appliances - Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and self-closing. PSCO identified various fire doors throughout the ship not self closing properly. 74SOLAS (14 CON) CH. II-2 Reg. 9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2016
Resolved 9 May 2016
Resolution: Coast Guard attended vessel and determined that deficiency was rectified satisfactorily.
Communications › Radio Communications › Satellite Communications Capability
Issued 6 May 2016
Resolved
1685 - Radio - Each Contracting Government undertakes to make available shore-based facilities for space and terrestrial radio communication services. The vessel did not have a qualified GMDSS technician on board and the vessel's captain was unable to produce a valid shore based maintenance plan for the GMDSS. 74 SOLAS (09 CON) CH. IV REG. 5.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2016
Resolved 9 May 2016
Resolution: Coast Guard attended vessel and determined that deficiency was rectified satisfactorily.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 6 May 2016
Resolved
0999 - Safety in General - Flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement approved by the Administration. PSCO observed that the paint in the paint locker was stacked above the nozzles preventing the system from operating as intended . 74 SOLAS (09CON) CH. II-2 Reg. 10.6.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2016
Resolved 9 May 2016
Resolution: Coast Guard attended vessel and determined that deficiency was rectified satisfactorily.