PEACE

PEACE is a 2000 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2000, most recently in October 2017, along with 22 deficiencies and 1 casualty investigation in 2007.

Records from 2000 to 2017. Most recent: inspection, 4 October 2017.

Built
2000
Last inspected
4 October 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964379 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH 2131
Flag
UNITED STATES
367443450, 367456650, 367594690 (licence lapsed)
Maury page id
psix-8795

Inspections, by type

…with no type recorded2
Years with a record 15 calendar years (2000–2017)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it303 - Convention (Subpart B), Gross Ton
89 - Regulatory (Subpart C or D), Gross Ton
90 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH2131MMSI 367594690 · cancelled · compulsorily equipped · granted 8 November 2013, cancelled 21 January 2020
WDF4862MMSI 367456650 · expired · voluntarily equipped · granted 10 June 2010, cancelled 15 August 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDF3739MMSI 367443450 · expired · voluntarily equipped · granted 17 March 2010, cancelled 23 May 2020 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 23

4 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281422
9 March 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5833920
19 October 2015 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5746235
27 July 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4392540
8 February 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4240796
18 July 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4086467
10 December 2010 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3919401
11 February 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3678806
7 December 2009 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3646722
26 July 2008 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3282237
26 November 2007 Administrative Inspection · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3104606
22 July 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3036238
3 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2901007
13 December 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2550946
1 December 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2724449
22 February 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2296712
18 February 2004 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2013435
23 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1854739
3 July 2002 Annual Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1636049
19 September 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431108
3 April 2001 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 1521179
29 August 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054063
14 June 2000 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397469

Deficiency record · 22

Electrical › Electric Generation Source (service) › Generator
Issued 9 March 2016 Resolved
Emergency stop switch not mounted properly for Port SSDG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 17 March 2016
Resolution: Stop switch for port generator was properly mounted.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 9 March 2016 Resolved
Main Shore Tie circuit breaker tab is partially missing.
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 17 March 2016
Resolution: Shore tie circuit breaker was replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 9 March 2016 Resolved
Storage Location not properly labeled.
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 17 March 2016
Resolution: CO2 storage area properly labeled.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 18 July 2011 Resolved
Wiring utilized for heat/smoke detection system was not Marine Grade. Found system with solid core plenum rated wires. Remove/replace all wiring with proper Marine Grade, IEEE during 2012 drydock. Conduct full test off all components of heat/smoke detection system in the presence of USCG
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2012
Resolved 30 July 2012
Resolution: Visually verified every single fire station pull box, every single MDE heat sensor and Generator''s heat sensors at the Fire Alarm Panel for both audible and visual alarms. Entire system replaced with proper Marine Grade IEEE wiring. All Satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2011 Resolved
Deck load cracked hull plate starboard side at above engine room. Port Captain cropped and renewed plate with out CG authorization. When Cg inspected repair noted that insert was to small. Crop and renew as indicated.
Action required: 705 - Other - as specified
Resolved 22 July 2011
Resolution: ABS rep witnessed repair of new insert and performed NDT. Sat.
Communications › Radio Communications › EPIRB
Issued 18 July 2011 Resolved
EPIRB Hydrostatic release was expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2011
Resolution: A new EPIRB and hydro release was installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2011 Resolved
Stbd exhaust piping was cracked around mixing elbow welds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2011
Resolution: Repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2011 Resolved
Several MDE exhaust support bolts were missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2011
Resolution: Bolts installed.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 18 July 2011 Resolved
Rescue ladder did not have securing devices to prevent ladder from falling overboard when deployed.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2011
Resolution: Chains were installed to prevent ladder from falling overboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 10 December 2010 Resolved
Renew four CO2 bottles for engine room space and recharge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 December 2010 Resolved
Conduct operational and pressure test of CO2 Piping in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2010
Communications › Alarms/Indicators › Fire Alarm
Issued 10 December 2010 Resolved
Confirm thermal sensor over #2 STBD MDE is operational as well as all other fire alarms in E/R.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 10 December 2010 Resolved
Repair electric plunger and shutdown solenoid on #4 port inboard MDE and demonstrate MDE shuts down when CO2 system is activated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 10 December 2010 Resolved
Resheath electrical wiring in cables as marked in E/R
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 10 December 2010 Resolved
Replace B-II fire extinguisher (#12) in E/R.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2010
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 April 2007 Resolved
The emergency exit from the forward crew seating area was not marked.
Due 30 April 2007
Resolved 3 April 2007
Resolution: Corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 13 December 2005 Resolved
Lock sewage/mark sewage overboard discharge valve. "Do not discharge within 3 miles of shore."
Due 13 January 2006
Resolved 4 January 2006
Resolution: Marked valve
Engineering › Fuel Oil Service System › Valve
Issued 13 December 2005 Resolved
Provide 2 spanner wrenches for emergency fuel shut off valves (port/stbd).
Due 13 January 2006
Resolved 4 January 2006
Resolution: PROVIDED 2 WRENCHES
Engineering › Fuel Oil Service System › Valve
Issued 13 December 2005 Resolved
Stencil Emergency fuel shut off valves (port/stbd).
Due 13 January 2006
Resolved 4 January 2006
Resolution: Stenciled valves.
Engineering › Steering Gear System › Actuator
Issued 23 July 2003 Resolved
Provide limit switches for main steering system gear in accordance with 46 CFR 182.610(f)(5). LEGACY COMPONENT DESC: Limit Switch
Action required: 705 - Other - as specified
Due 23 August 2003
Resolved 6 May 2005
Resolution: Vessel rep provided documentation to satisfy prior limit switch deficiency.
Accommodation/Occupational Safety
Issued 14 June 2000 Resolved
PROVIDE DOCUMENTATION THAT THE PRESSURE VESSELS MEET THE REQUIREMENTS OF 46CFR 54.01-5.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Documentation
Issued 14 June 2000 Resolved
POST STABILITY LETTER IN WHEEL HOUSE PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 14 July 2000
Resolved 24 July 2000

Casualty record · 1

22 July 2007Routine · role: Involved in a Marine Casualty · activity 3036238
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GULF PEACE (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.