← All vessels
PEACE
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named PEACE
PEACE is a 2000 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2000, most recently in October 2017, along with 22 deficiencies and 1 casualty investigation in 2007.
Records from 2000 to 2017. Most recent: inspection, 4 October 2017.
- Built
- 2000
- Last inspected
- 4 October 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 22 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2007
Identity
1098147
8964379 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH 2131
8795
Flag
UNITED STATES
367443450, 367456650, 367594690 (licence lapsed)
Maury page id
psix-8795
Inspections, by type
…with no type recorded2
Years with a record
15 calendar years (2000–2017)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it303 - Convention (Subpart B), Gross Ton
89 - Regulatory (Subpart C or D), Gross Ton
90 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
89 - Regulatory (Subpart C or D), Gross Ton
90 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDH2131MMSI 367594690 · cancelled · compulsorily equipped · granted 8 November 2013, cancelled 21 January 2020
WDF4862MMSI 367456650 · expired · voluntarily equipped · granted 10 June 2010, cancelled 15 August 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDF3739MMSI 367443450 · expired · voluntarily equipped · granted 17 March 2010, cancelled 23 May 2020 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 23
4 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281422
9 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5833920
19 October 2015
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5746235
27 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4392540
8 February 2012
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4240796
18 July 2011
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4086467
10 December 2010
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3919401
11 February 2010
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3678806
7 December 2009
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3646722
26 July 2008
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3282237
26 November 2007
Administrative Inspection · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3104606
22 July 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3036238
3 April 2007
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2901007
13 December 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2550946
1 December 2005
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2724449
22 February 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2296712
18 February 2004
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2013435
23 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1854739
3 July 2002
Annual Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1636049
19 September 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431108
3 April 2001
Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 1521179
29 August 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054063
14 June 2000
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397469
Deficiency record · 22
Electrical › Electric Generation Source (service) › Generator
Issued 9 March 2016
Resolved
Emergency stop switch not mounted properly for Port SSDG.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 9 March 2016
Resolved
Main Shore Tie circuit breaker tab is partially missing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 9 March 2016
Resolved
Storage Location not properly labeled.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 18 July 2011
Resolved
Wiring utilized for heat/smoke detection system was not Marine Grade. Found system with solid core plenum rated wires. Remove/replace all wiring with proper Marine Grade, IEEE during 2012 drydock. Conduct full test off all components of heat/smoke detection system in the presence of USCG
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2011
Resolved
Deck load cracked hull plate starboard side at above engine room. Port Captain cropped and renewed plate with out CG authorization. When Cg inspected repair noted that insert was to small. Crop and renew as indicated.
Communications › Radio Communications › EPIRB
Issued 18 July 2011
Resolved
EPIRB Hydrostatic release was expired.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2011
Resolved
Stbd exhaust piping was cracked around mixing elbow welds.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2011
Resolved
Several MDE exhaust support bolts were missing.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 18 July 2011
Resolved
Rescue ladder did not have securing devices to prevent ladder from falling overboard when deployed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 10 December 2010
Resolved
Renew four CO2 bottles for engine room space and recharge.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 December 2010
Resolved
Conduct operational and pressure test of CO2 Piping in engine room.
Communications › Alarms/Indicators › Fire Alarm
Issued 10 December 2010
Resolved
Confirm thermal sensor over #2 STBD MDE is operational as well as all other fire alarms in E/R.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 10 December 2010
Resolved
Repair electric plunger and shutdown solenoid on #4 port inboard MDE and demonstrate MDE shuts down when CO2 system is activated.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 December 2010
Resolved
Resheath electrical wiring in cables as marked in E/R
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 10 December 2010
Resolved
Replace B-II fire extinguisher (#12) in E/R.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 April 2007
Resolved
The emergency exit from the forward crew seating area was not marked.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 13 December 2005
Resolved
Lock sewage/mark sewage overboard discharge valve. "Do not discharge within 3 miles of shore."
Engineering › Fuel Oil Service System › Valve
Issued 13 December 2005
Resolved
Provide 2 spanner wrenches for emergency fuel shut off valves (port/stbd).
Engineering › Fuel Oil Service System › Valve
Issued 13 December 2005
Resolved
Stencil Emergency fuel shut off valves (port/stbd).
Engineering › Steering Gear System › Actuator
Issued 23 July 2003
Resolved
Provide limit switches for main steering system gear in accordance with 46 CFR 182.610(f)(5). LEGACY COMPONENT DESC: Limit Switch
Accommodation/Occupational Safety
Issued 14 June 2000
Resolved
PROVIDE DOCUMENTATION THAT THE PRESSURE VESSELS MEET THE REQUIREMENTS OF 46CFR 54.01-5.
Documentation
Issued 14 June 2000
Resolved
POST STABILITY LETTER IN WHEEL HOUSE PRIOR TO CARRYING PASSENGERS
Casualty record · 1
22 July 2007Routine · role: Involved in a Marine Casualty · activity 3036238
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
GULF PEACE (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.