ICE FIGHTER is a 2006 tank ship. The Coast Guard has recorded 19 inspections since 2017, most recently in June 2026, along with 5 deficiencies and 5 operational controls.
Records from 2017 to 2026. Most recent: inspection, 11 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it38832 - Regulatory (Subpart C or D), Gross Ton 38832 - Convention (Subpart B), Gross Ton 21409 - Regulatory (Subpart C or D), Net Ton 70374 - Dead Weight, Metric Ton 83495 - Displacement, Metric Ton 21409 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 19
11 June 2026PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8394952
9 June 2023COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7704823
8 June 2023Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7704012
31 May 2023Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7701604
19 January 2023COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7623970
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2020Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Port State Control Examiner observed a soft patch on the drain line for the OWS system.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 March 2020
Resolved 21 April 2020
Resolution: The subject line was cut and a new insert fitted, after which the line was
satisfactorily tested.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 15 February 2019Resolved
The company should ensure that the policy is implemented and maintained at all levels of organization, both ship based and shore based. PSCO observed a lack of response and action to scheduled maintenance and calibration requests on critical systems/equipment, allowing a lapse in multiple inspection and calibration dates. As per the ship’s SMS, overdue PMS jobs for critical equipment should not be tolerated and the maintenance must be carried out as soon as practicable. The following details were observed by PSCO:
1) Per the ship’s PMS, the M/E Oil Mist Detection system, shall have a periodic inspection conducted, by the maker’s service engineer, every 2.5 years. The periodic inspection due date was 10JULY2018. Records indicated that the C/E has notified the company of the periodic inspection deadline on 17JUNE2018, but no service engineer has attended the ship since the request.
2) Per the ship’s PMS, the Oil Discharge Monitoring Equipment, shall have an annual servicing conducted by an authorized service engineer (shore technician). Last annual service was on 03NOV2017, with the next annual servicing being on 03NOV2018. C/O has notified the company of this service on 06SEP2018, but no shore technician has attended and conducted the inspection since the submitted request.
3) Per the ship’s PMS update on 28MARCH2018, the Fixed Gas Detection system shall have the 3-monthly zero/span calibration conducted on a monthly basis. Although the company did impose more strict requirements on this system, than required by regulation, calibration records indicate that the competent officer(s) in charge of this evolution have continued to log the calibration evolution as a 3 monthly calibration inspection on some months while logging it as a monthly inspection on other months. In addition, calibration logs provided, also show that this PMS update was not logged and possibly not conducted during the month of May 2018 and July 2018.
The company and crew failed to fully implement the requirements of the ISM code through their SMS procedures. The above non-conformities on critical systems is evidence that the company an crew are not complying with shipboard SMS requirements. Recommend external audit on the maintenance and inspection (CP11) portion of the SMS. 17 abc/74SOLAS(14)CH IX,REG 3.1/ISM Code 2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2019
Resolution: ODME and M/E Fuel Mist Detector calibrated. External audit completed, identified non-conformity by Auditor. See attachment for further details.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 15 February 2019Resolved
The normal equipment for every lifeboat shall consist of a food ration totaling not less than 10,000KJ for each person the lifeboat is permitted to accommodate. These rations shall be kept in airtight packaging and be stowed in a weather tight container. 51 food rations have damaged packaging which may have caused the food rations to be unusable. 17 ac/74SOALS(14)CH III, REG 34/LSA Code 4.4.8.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2019
Resolution: Lifeboat rations replaced. All sat. See attachment for further details.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 15 February 2019Resolved
Ship shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the administration in accordance with the provisions of regulation XI-I/I, or with applicable national standards of the administration with provide an equivalent level of safety. PSCO discovered a soft patch on a drainage line in crew laundry. 40 ac/74SOLAS(14),CH II-1, REG 3-1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2019
Resolution: Pipe repair completed. See attachment for further details.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 15 February 2019Resolved
An immersion suit shall be constructed with waterproof materials. PSCO observed a hole in the glove of 01 immersion suits. 10 c/74SOLAS(14), CH III, REG 32.3.2/LSA Code 2.3.1.1
Action required: 10 - Deficiency Rectified
Resolved 15 February 2019
Resolution: Vessel had extra immersion suits onboard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.