MAURY USCG vessel records
← All vessels

MISS JUDY

MISS JUDY is a 1944 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in May 2025, along with 31 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 20 May 2025.

Built
1944
Last inspected
20 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 May 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

880277
Flag
UNITED STATES
Maury page id
psix-880277

Documentation record

Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

20 May 2025 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8140135
16 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8113954
15 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7918064
10 January 2024 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848780
11 January 2023 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7624431
26 January 2022 Internal Structural Exam · Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7391930
5 March 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150925
16 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002843
26 March 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660381
24 October 2018 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580048
25 July 2018 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507153
2 May 2018 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6420445
10 October 2017 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6285798
2 March 2017 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6098355
2 March 2017 Deficiency Check · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6101716
7 July 2016 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5932680
11 February 2016 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5814406

Deficiency record · 31

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 April 2025 Resolved
At each initial and subsequent inspection all accessible parts of the hull shall be inspected. During inspection of the hull a crack was found near the propeller. During the underway portion of the inspection the crack allowed water to penetrate and collect in the rear STBD bilge. Operator must submit a repair proposal and conduct repairs in accordance with the approved proposal and notify MSD Fort Smith when complete to conduct underway tests on repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2025
Resolved 20 May 2025
Resolution: Vessel was float tested in the presence of a Marine Inspector with satisfactory results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024 Resolved
Engine exhaust pipe installation must be suitably insulated or shielded from combustible material. Vessels dry engine exhaust pipping from a gasoline powered engine found without out proper insulation. Owner shall properly insulate the engine exhaust system within 30 days of the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets. The words FIRE BUCKET must be stenciled in a contrasting color on each bucket. Vessel was found with three 4 1/2 gallon buckets. Owner shall replace with the 2 1/2 gallon buckets and stencil FIRE BUCKET on each.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photo of the fire buckets meeting the requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2024 Resolved
The Vessel is required to process sistering information to Marine Safety Center(MSC) and get a stability letter prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member until the stability test process is completed and approved. Complete prior to August 30th 2024.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 10 October 2024
Resolution: New stability letter issued sistering the vessel to the ZACHARY O.N. CG880279
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024 Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2024
Resolution: Owner [name withheld] modifications and waiting on MSC stabilty letter
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 January 2022 Resolved
Fire Fighting equipment sevicing is expired. All fighting equipment shall be serviced annually. Provided servicing documentation prior to embarking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2022
Resolution: Vessel had Fighter extingishers inspected and approved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 January 2022 Resolved
Properly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 24 March 2022
Resolution: Vessels Owner properly marked and stowed PFD's on board the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 January 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2022 Resolved
Replace retro reflective tape on three Child PFD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2022
Resolved 24 March 2022
Resolution: retro reflective tape has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 January 2022 Resolved
Replace plastic pipping on the Higgins bilge pump with apporved Ferrous material pipping.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 28 April 2022
Resolution: Vessel Owner replaced pipping with approved material.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2022 Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 27 February 2022
Resolved 24 March 2022
Resolution: Vessel owner installed valve to show the fuel valve is open or shut.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 January 2022 Resolved
Properly mark and stow PFD's in the correct vessel. Adult PFD's and Child PFD's shall be stowed and marked in the proper locations.
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 24 March 2022
Resolution: Vessels Owner properly marked and stowed PFD's on board the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021 Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed COI on vessel.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021 Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid stability letter on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed stability letter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Segregated child sized life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2021 Resolved
All electrical equipment and circuits must be clearly marked and identified. The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Labeled NAV lighs
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2021 Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew. The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: Replaced First Aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2021 Resolved
Remote fuel shutoff valves must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation. Fuel shut off valve either not labeled or not fully visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Labeled Fuel Shut off valves.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021 Resolved
Each life ring on a vessel must be approved under 160.050, be readily accessible, be stowed in a way that it can be rapidly cast loose, and not permanently secured in anyway. The life ring w/ line was not stowed in a fashion that allowed for it to be rapidly cast loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Installed new lifebuoy arrangement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2021 Resolved
At each inspection and subsequent inspection the owner operator shall be prepared to conduct testing of machinery alarms, including bilge high level alarms. The FWD bilge alarm on STBD side was inop.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: Replaced bilge alarm/pump.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2021 Resolved
A vessel not required to have an engine driven fire pump must have at least three 2.5gallon fire buckets w/ a lanyard attached satisfactory to the OCMI, placed so as to be easily available during an emergency. The fire buckets were stowed in the overhead behind "captains tip" sign and not easily removable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Replaced Fire Buckets
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2021 Resolved
Each vessel must be marked as required by 46 CFR 67. The vessel did not have the name stenciled on either side of the bow.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Stenciled vessel name on the bow.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 July 2020 Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 29 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 16 July 2020 Resolved
Clean bilge of all debris and oil.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 29 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 July 2020 Resolved
Ring life buoy line is tangled preventing rapid deployment.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 29 December 2021
Engineering › Bilge Water Management System › Interface Detector
Issued 2 March 2017 Resolved
Found 02 bilge high level alarms were not operational (did not produce audible or visual indicator). Repair high level alarms to satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2017
Resolved 15 March 2017
Resolution: Coupling was replaced and driveshaft was reconnected.
Operations/Management › Vessel Activity › Construction/Repair
Issued 2 March 2017 Resolved
While taking the DUKW out of the water, male end of drive shaft seperated from female end. Femaled end was badly damaged. Replace female coupling and reattach drive shaft prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2017
Resolved 15 March 2017
Resolution: Bilge High Level Alarm was fixed, test satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 February 2016 Resolved
Found 07 adult and 01 child lafejackets unsat (bad retro reflective tape, ripped, etc.). Replace lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 7 July 2016
Resolution: Lifejackets were replaced.
Lifesaving › Lifebuoys › Approval
Issued 11 February 2016 Resolved
Lifebuoy was not CG-approved. Replace lifebuoy with one that is approved to 46 CFR 170.050 standards.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2016
Resolved 7 July 2016
Resolution: Ring Life buoy was replaced with one that is CG approved.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 11 February 2016 Resolved
Vessel does not have warning sign for blowers (must be operated for sufficient time to allow for one air change). Provide sign.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 7 July 2016
Resolution: Warning signs were added to the blowers.

Ownership record