Records from 2007 to 2026. Most recent: inspection, 27 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
27 April 2026
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8361571
23 September 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8243290
17 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8113972
15 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7917883
26 September 2023
Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7827497
26 April 2023
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7677324
14 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7434124
22 April 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7194372
5 March 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150955
21 August 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7044036
15 July 2020
Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002886
26 March 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660406
24 October 2018
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580052
25 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507168
22 January 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6342156
10 October 2017
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6285565
24 January 2017
Drydock Exam · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6076960
18 March 2016
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6020949
11 February 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5814337
10 June 2014
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4890142
18 March 2014
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4820237
17 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4820269
17 February 2012
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4246565
19 February 2010
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3682334
14 December 2009
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3650089
3 March 2009
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3430379
18 April 2008
Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3187012
2 April 2008
Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3177509
25 May 2007
Initial Certification
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2948495
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 May 2024
Resolved
Vessel hull damaged in the wheel well next to the drive shaft on the star board side. well seam weld was damaged in the area of the hull as well. owner shall repair the hull in accordance with steel repair guidance.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: Owner repaired area of the hull with a 12x12 insert and welds were tested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 May 2024
Resolved
Engine exhaust pipe installation must be suitably insulated or shielded from combustible material. Vessels dry engine exhaust pipping from a gasoline powered engine found without out proper insulation. Owner shall properly insulate the engine exhaust system within 30 days of the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets. The words FIRE BUCKET must be stenciled in a contrasting color on each bucket. Vessel was found with three 4 1/2 gallon buckets. Owner shall replace with the 2 1/2 gallon buckets and stencile FIRE BUCKET on each with in 7 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2024
Resolution: Vessel rep sent photos of the fire buckets that met the reglatory requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 September 2023
Resolved
The Vessel is required to conduct a stability test prior to operating with full COI passenger count. The vessel is restricted to the carriage of 26 passengers and 1 crew member ub tilthe stability test is completed and approved. Comlete prior to March 10th 2024.
Action required: 705 - Other - as specified
Due 10 March 2024
Resolved 30 May 2024
Resolution: New stabilty latter issued by MSC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2023
Resolved
Vessel Portside Navigation light was inoperable. Vessel Shall keep all navigation equipment in operational condition.
repair within 7 days.
Action required: 705 - Other - as specified
Due 3 May 2023
Resolved 10 May 2023
Resolution: Owner repair nav light and is operational
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2023
Resolved
Vessel stern light was broken and inoperable. Vessel replaced the stern light while inspectors were at the location.
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 26 April 2023
Resolution: Owner replaced stern nav light; light is operational
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 April 2023
Resolved
Fist aid Kit was expired. Vessel shall keep First aid kits in compliance. Replace within 7 days.
Action required: 705 - Other - as specified
Due 3 May 2023
Resolved 10 May 2023
Resolution: Owner replaced the first aid kit with one that meets the requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021
Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed watertight box to maintain documents onboard vessel.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021
Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request.
The vessel does not maintain a valid stability letter on
board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2021
Resolution: Installed watertight box to maintain documents onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Separated child life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021
Resolved
All electrical equipment and circuits must be clearly marked and identified.
The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Labeled NAV lights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2021
Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew.
The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced First aid kits
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2021
Resolved
Each life ring on a vessel must be approved under 160.050, be readily accessible, be stowed in a way that it can be rapidly cast loose, and not permanently secured in anyway.
The life ring w/ line was not stowed in a fashion that allowed for it to be rapidly cast loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
Resolution: Installed new lifebuoy
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2021
Resolved
At each inspection for certification the owner/operator shall be prepared to conduct tests of the main propulsion machinery.
During testing, the prop shaft seal was found to be leaking.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2020
Resolved
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI.
The vessel experienced a pinhole leak on the transmission fluid line while on tour.
Repair to the satisfaction of attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2020
Resolution: Witnessed replacement and normal operations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020
Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 15 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020
Resolved
Clean bilge of all debris and oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 July 2020
Resolved
Repair pin hole in hull approx. 6in starboard of prop shaft and 6 in aft of Higgins pump sprocket.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019
Resolved
Outer cover of fuel line found dry rotting and cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 May 2019
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 January 2018
Resolved
Found 01 child lifejacket that was not labeled with the vessel name. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 23 January 2018
Resolution: Lifejacket was labeled. Corrected on spot.
Construction/Loadline › Hull › Weld
Issued 22 January 2018
Resolved
Found an approximately 2" long crack in weld seam in port aft wheel well. Gouge and reweld weld seam.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 28 February 2018
Resolution: Weld was gouged and rewelded.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 22 January 2018
Resolved
Found cotter pin on propeller improperly installed. Corrected on spot.
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 23 January 2018
Resolution: Correct on spot. Cotter pin was removed and replaced.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 22 January 2018
Resolved
Found that navigation lights were not operational. Corrected on spot by fixing a loose wire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 23 January 2018
Resolution: Corrected on spot by fixing a loose wire.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 January 2017
Resolved
Crew training has not been conducted since last summer (AUG 16). Training for emergency procedures shall be conducted once every three months. Conduct training prior to getting underway with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2017
Resolved 15 March 2017
Resolution: Drills were conducted and properly documented.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 January 2017
Resolved
Management Information System (MIS) Data reporting has not been completed for 2016. Submit form U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection to Commandant (CG-INV) by March 15.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: MIS reports were submitted.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 11 February 2016
Resolved
Found 28 adult and 03 child lifejackets unsatisfactory (missing retro-reflective tape, ripped, etc.) Replace life jackets to staisfaction of CG Marine Inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Lifejackets were replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 February 2016
Resolved
Lifebuoy was not marked with vessel's name. Mark ring buoy IAW 46 CFR 185.604 (b). Marking must be "Legible Block Letters."
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Lifebuoy was marked.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 11 February 2016
Resolved
Vessel does not have warning sign for blowers (must be operated for sufficient time to allow one air change). Provide Sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Warning signs were posted on all DUKW vessels.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 11 February 2016
Resolved
Fuel shutoff valve label is not clearly legible. Re-label fuel shut-off in 1-inch letters to the satisfaction of the attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Fuel shutoff valve was relabeled.
Construction/Loadline › Penetrations › Weld
Issued 10 June 2014
Resolved
Vessel has multiple holes and excessive weld material in the hull in the vicinity of both carrier bearing mounts. Crop and renew hull material and properly install bearing. 46 CFR 176.802(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2014
Resolution: Replaced plate and installed bearing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 17 March 2014
Resolved
Vessel's Fixed Fire Extinguishing System is not approved by MSC. The
nozzles were deemed too small for the system. The vessel is required to carry an additional B-II fire extinguisher until the system meet the requirements of 46 CFR 181.410(f)(4)(v).
Action required: 705 - Other - as specified
Due 31 January 2015
Resolved 10 October 2017
Resolution: Fire system was replaced with a 35 lb CO2 bottle, approved by local OCMI.
Documentation › Certificates/Documents › Stability Letter
Issued 17 February 2012
Resolved
Stability letter denotes 30 passengers allowed, where as COI denotes 31 persons allowed. Until the issue is resolved or a new COI issued, a CG-835 will be issued limiting the number of passengers to 29, making total number of persons allowed 30.
Action required: 705 - Other - as specified
Due 17 April 2012
Resolved 11 February 2016
Resolution: This CG-835 was administratively cleared. The COI has been amended to allow a maximum of 30 passengers.
Communications › Audible Communications › Horn/Whistle
Issued 1 March 2010
Resolved
The button for the horn needs to be replaced
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 11 May 2010
Engineering › Bilge Water Management System › Eductor
Issued 1 March 2010
Resolved
The drive chain for the higgins pump was found loose and needs to be tightened.
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 11 May 2010
Engineering › Bilge Water Management System › Piping
Issued 3 March 2009
Resolved
Higgins Pump hose not double clamped.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Fire Fighting › Fire Bucket › Stenciling
Issued 3 March 2009
Resolved
Not stenciled.
Condition: Improper Installation
Due 11 March 2009
Resolved 11 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2009
Resolved
Throughout the vessel, plastic straps were used to attached wires to the vessel's hull.
Condition: Improper Installation
Due 11 March 2009
Resolved 11 March 2009
Engineering › Steering Gear System › Rudder
Issued 3 March 2009
Resolved
Rudder packing leaking excessively.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Construction/Loadline › Markings › Load Line Mark
Issued 3 March 2009
Resolved
Freeboard line needs to be marked on the hull
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2009
Resolved
Children lifejacket stowed location not appropriately marked as 46 CFR 180.78 (a) (5)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 3 March 2009
Resolved
Exhaust guards not mounted
Condition: Improper Installation
Due 18 March 2009
Resolved 11 March 2009
Engineering › Freshwater System (intermediary cooling) › Storage Tank
Issued 2 April 2008
Resolved
Coolant overfill tank was missing its cap.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 2 April 2008
Resolution: Operator placed a new cap on the tank.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 2 April 2008
Resolved
Excess water in the port aft bilge as well as in the engine compartment bilge
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 2 April 2008
Resolution: The water was evacuated from the bilges.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 2 April 2008
Resolved
Several life jackets were marked with the wrong VSL name or the name was fading away.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 18 April 2008
Resolution: Corrected vessel name on all life jackets.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 2 April 2008
Resolved
The front drive-shaft support bar is rubbing against the rubber boot seal on the rear of the front drive-shaft. The mounts for this support bar need to be moved forward and down in order to clear the boot. The mounts were moved because the hull has been modified from the original design.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 18 April 2008
Resolution: Relocated support bar to clear seal.
Engineering › Bilge Water Management System › Pump
Issued 2 April 2008
Resolved
The drive chain on the higgins pump needs to be tightened.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 18 April 2008
Resolution: Tightened chain.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 April 2008
Resolved
Two of the PFD's need new reflective tape. Owner says he will purchase new vests.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 18 April 2008
Resolution: Installed new PFD''s.
Documentation › Safety Management System › Potential Emergency Situations ID Procedures
Issued 2 April 2008
Resolved
VSL does not have emergency instructions posted.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 18 April 2008
Resolution: Posted emeregency instructions.