Records from 2008 to 2026. Most recent: inspection, 4 February 2026.
Documentation record
Registered dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
Registered tonnagegross 2,174 / net 814
ITC dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
ITC tonnagegross 2,174 / net 814
BuilderBENDER SHIPBUILDING & REPAIR · MOBILE, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 May 2026 · expires 31 May 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4636 - Displacement, Ton
2174 - Convention (Subpart B), Gross Ton
814 - Convention (Subpart B), Net Ton
2972 - Dead Weight, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
4 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8306318
21 July 2025
Deficiency Check · Periodic Inspection · Administrative Inspection · ISM Oversight · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8191265
13 May 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7903998
6 March 2023
In-Service Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7644953
21 June 2019
MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 6689397
18 October 2018
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6539351
6 September 2017
Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Activities Europe · Activity 6248313
13 March 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6103531
4 November 2016
Type not recorded
No type recorded · Activities Europe · Activity 6035050
4 November 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6035057
17 October 2016
ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 6010281
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 8 August 2025
Resolved
Certificates shall be issued or endorsed either by the Administration or organization authorized by it.
ABS has yet to issue certain international certificates.
Action required: 702 - Prior to embarking on international voyage
Resolved 3 October 2025
Resolution: Class surveryor emailed MI attesting to issuing corrected certificates.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2025
Resolved
Vessels enrolled in the ACP must utilize products marked with a CG approval number as listed in the Single Supplement.
Lifejackets must be marked with series 160.155.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 4 September 2025
Resolution: Verified replacement life jackets IAW 160.155.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 8 August 2025
Resolved
Launching instructions shall illustrate the purpose of controls and the procedures for operating the appliance and give relevant instructions or warnings.
Port side liferafts sheet requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 4 September 2025
Resolution: Verified new instructions posted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 21 July 2025
Resolved
Cargo shall be loaded, stowed and secured throughout the
voyage IAW Cargo Securing Manual approved by the Administration. Cargo Securing Manual not present for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 25 September 2025
Resolution: Vessel rep provided photo copy of ABS approved Cargo Securing Manual.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 June 2019
Resolved
Valves for fixed CO2 systems must be marked and locked in accordance with operating instructions.
Action required: 10 - Deficiency Rectified
Due 21 June 2019
Resolved 21 June 2019
Resolution: Deficiency was corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 October 2018
Resolved
Every ship shall be provided with a fixed deck foam system; the deck foam system shall be capable of simple and rapid operation. Baffle inside foam storage tank is broken, rendering foam system inoperable. Vessel is prohibited from carrying methanol until fixed foam system is made operable. [IBC Code 11.3.1/11.3.4]
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 29 November 2018
Resolution: Received email from Master with attached ABS Survey Report attesting to satisfactory repairs having been made to the foam tank (see Documents for further information).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 October 2018
Resolved
All the steering gear components shall be of sound and reliable construction to the satisfaction of the Administration. During test of the emergency steering, the steering gear was "surging" or "hunting" in both directions while seeking the requested rudder angle. Problem was corrected on the spot by Cheif Engineer, who found the suction line loose on the #1 port steering gear pump. [SOLAS 2014 II-1/29.2.1]
Action required: 10 - Deficiency Rectified
Due 18 October 2018
Resolved 18 October 2018
Resolution: Problem was corrected on the spot by Cheif Engineer, who found the suction line loose on the #1 port steering gear pump.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2018
Resolved
In cargo ships, the failure of the oil-level gauges shall not permit release of fuel into the space. The Administration may permit the use of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks. Flat glasses were missing for 3 tanks in engine room (2 day tanks & 1 settling tank). [SOLAS 2014 II-2/4.2.2.3.5.2.2]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2018
Resolved 7 November 2018
Resolution: Received photographs from the Master showing satisfactory replacement of the three missing flat glasses (see photographs in Documents for further information).
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 18 October 2018
Resolved
Each discharge into the sea or to a reception facility shall be promptly recorded in the Garbage Record Book and signed for on the date of the discharge by the officer in charge. Ship's Garbage Record Book was missing 2 entries for which discharge receipts were provided (2 August; 27 August 2018). Omission was corrected on the spot with amended entries and crew was educated on requirements. [MARPOL 2017 Cons. V/10.3.1]
Action required: 10 - Deficiency Rectified
Due 18 October 2018
Resolved 18 October 2018
Resolution: Omission was corrected on the spot with amended entries and crew was educated on requirements.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 September 2017
Resolved
COI requires 4 total personnel with Fast Rescue Boat endorsements. Vessel has 3 personnel with that endorsement. Vessel is restricted to operations in Angola until deficiency is rectified and signed off by a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 October 2017
Resolution: master sent crew list and certs to CG ACTEUR as proof of compliance. Vessel can now operate outside of Angolan waters.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 4 November 2016
Resolved
Provide a class report attesting to the proper operation of the STBD drive. Vessel reported an overheating bearing in the stbd drive.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 16 November 2016
Resolution: Vessel provided a class report attesting to the proper operation of the stbd drive.
Stability › Watertight Integrity › General
Issued 17 October 2016
Resolved
Replace sponge gaskets on the following QAWTD, Bow thruster room, tank farm, drive gear room, steering gear room, steering gear room and emergency escape.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Stability › Watertight Integrity › General
Issued 17 October 2016
Resolved
Adjust the following following quick acting watertight scuttles, Bow thruster room, drive room emergency escape, steering gear room emergency escape.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 October 2016
Resolved
Adjust the following fire doors, Officers deck, crew deck, focsle deck, focsle deck head, main deck, mess deck, lounge, galley, chill/freezer, changing room, laundry room, switchboard room.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Engineering › Pressure Vessel › Relief Valve
Issued 17 October 2016
Resolved
Install a pressure relief valve on the water heater.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Discharge Hose
Issued 17 October 2016
Resolved
Replaced chaffed hose.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 17 October 2016
Resolved
Use lockout tagout as per SMS to secure U/V Purifier breaker
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 October 2016
Resolved
Install protective cover for J-box in the bow thruster room.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 17 October 2016
Resolved
Flammable liquids stored throughout the vessel and not in flame lockers.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 October 2016
Resolved
Secure freezer and refrigerator on mess deck.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 October 2016
Resolved
Install SOLAS stickers in accordance with fire and safety plan throughout the vessel.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.