RENEE LAB

RENEE LAB is a 2007 industrial vessel. The Coast Guard has recorded 30 inspections since 2007, most recently in February 2026, along with 48 deficiencies, 2 operational controls and 2 casualty investigations between 2008 and 2016.

Records from 2007 to 2026. Most recent: inspection, 4 February 2026.

Built
2007
Last inspected
4 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9407770 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
880286
Flag
UNITED STATES
366207000, 368285000, 368291000, 368378000
Maury page id
psix-880286

Inspections, by type

…with no type recorded3
Years with a record 15 calendar years (2007–2026)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
Registered tonnagegross 2,174 / net 814
ITC dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
ITC tonnagegross 2,174 / net 814
BuilderBENDER SHIPBUILDING & REPAIR · MOBILE, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 May 2026 · expires 31 May 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4636 - Displacement, Ton
2174 - Convention (Subpart B), Gross Ton
814 - Convention (Subpart B), Net Ton
2972 - Dead Weight, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WRLQMMSI 366207000 · active · compulsorily equipped · granted 20 May 2025, expires 20 May 2035
WAJOMMSI 368285000 · active · compulsorily equipped · granted 28 June 2024, expires 28 June 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDN6757MMSI 368378000 · active · compulsorily equipped · granted 15 March 2023, expires 15 March 2033 · licensed under a name not among this hull’s recorded names (not shown)
WDD7312MMSI 368291000 · active · compulsorily equipped · granted 27 April 2017, expires 3 May 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 30

4 February 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8306318
21 July 2025 Deficiency Check · Periodic Inspection · Administrative Inspection · ISM Oversight · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8191265
13 May 2024 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7903998
6 March 2023 In-Service Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7644953
21 June 2019 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 6689397
18 October 2018 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 6539351
6 September 2017 Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Activities Europe · Activity 6248313
13 March 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6103531
4 November 2016 Type not recorded
No type recorded · Activities Europe · Activity 6035050
4 November 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6035057
17 October 2016 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 6010281
5 August 2015 Deficiency Check · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 5206350
12 August 2014 MTSA/ISPS Verification · ACP Annual Oversight · Deficiency Check
Physical examination · Activities Europe · Activity 4952262
28 March 2014 Administrative Inspection
Administrative · Activities Europe · Activity 4824561
5 February 2012 Deficiency Check · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Activities Europe · Activity 4221185
9 February 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3942080
30 July 2009 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3550376
18 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3419747
30 October 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3354253
9 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3341221
5 August 2008 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3289554
18 June 2008 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3240578
13 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3182942
13 April 2008 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3182996
12 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3183710
29 February 2008 Deficiency Check · Administrative Inspection · MARPOL Annex II Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3140168
7 November 2007 MARPOL Annex V Examination · MARPOL Annex II Examination · Ballast Water Examination · Construction Oversight · ACP COI Oversight · MARPOL Annex I Examination · Initial Construction-Excluding Oversight · Welding Related Inspections Qualification Testing · ISM Oversight · Initial Certification · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3095365
2 November 2007 Administrative Inspection · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3091895
15 October 2007 Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3080262
7 May 2007 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 2926361

Deficiency record · 48

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 8 August 2025 Resolved
Certificates shall be issued or endorsed either by the Administration or organization authorized by it. ABS has yet to issue certain international certificates.
Action required: 702 - Prior to embarking on international voyage
Resolved 3 October 2025
Resolution: Class surveryor emailed MI attesting to issuing corrected certificates.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2025 Resolved
Vessels enrolled in the ACP must utilize products marked with a CG approval number as listed in the Single Supplement. Lifejackets must be marked with series 160.155.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 4 September 2025
Resolution: Verified replacement life jackets IAW 160.155.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 8 August 2025 Resolved
Launching instructions shall illustrate the purpose of controls and the procedures for operating the appliance and give relevant instructions or warnings. Port side liferafts sheet requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2025
Resolved 4 September 2025
Resolution: Verified new instructions posted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 21 July 2025 Resolved
Cargo shall be loaded, stowed and secured throughout the voyage IAW Cargo Securing Manual approved by the Administration. Cargo Securing Manual not present for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2025
Resolved 25 September 2025
Resolution: Vessel rep provided photo copy of ABS approved Cargo Securing Manual.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 June 2019 Resolved
Valves for fixed CO2 systems must be marked and locked in accordance with operating instructions.
Action required: 10 - Deficiency Rectified
Due 21 June 2019
Resolved 21 June 2019
Resolution: Deficiency was corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 October 2018 Resolved
Every ship shall be provided with a fixed deck foam system; the deck foam system shall be capable of simple and rapid operation. Baffle inside foam storage tank is broken, rendering foam system inoperable. Vessel is prohibited from carrying methanol until fixed foam system is made operable. [IBC Code 11.3.1/11.3.4]
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 October 2018
Resolved 29 November 2018
Resolution: Received email from Master with attached ABS Survey Report attesting to satisfactory repairs having been made to the foam tank (see Documents for further information).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 October 2018 Resolved
All the steering gear components shall be of sound and reliable construction to the satisfaction of the Administration. During test of the emergency steering, the steering gear was "surging" or "hunting" in both directions while seeking the requested rudder angle. Problem was corrected on the spot by Cheif Engineer, who found the suction line loose on the #1 port steering gear pump. [SOLAS 2014 II-1/29.2.1]
Action required: 10 - Deficiency Rectified
Due 18 October 2018
Resolved 18 October 2018
Resolution: Problem was corrected on the spot by Cheif Engineer, who found the suction line loose on the #1 port steering gear pump.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2018 Resolved
In cargo ships, the failure of the oil-level gauges shall not permit release of fuel into the space. The Administration may permit the use of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks. Flat glasses were missing for 3 tanks in engine room (2 day tanks & 1 settling tank). [SOLAS 2014 II-2/4.2.2.3.5.2.2]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2018
Resolved 7 November 2018
Resolution: Received photographs from the Master showing satisfactory replacement of the three missing flat glasses (see photographs in Documents for further information).
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 18 October 2018 Resolved
Each discharge into the sea or to a reception facility shall be promptly recorded in the Garbage Record Book and signed for on the date of the discharge by the officer in charge. Ship's Garbage Record Book was missing 2 entries for which discharge receipts were provided (2 August; 27 August 2018). Omission was corrected on the spot with amended entries and crew was educated on requirements. [MARPOL 2017 Cons. V/10.3.1]
Action required: 10 - Deficiency Rectified
Due 18 October 2018
Resolved 18 October 2018
Resolution: Omission was corrected on the spot with amended entries and crew was educated on requirements.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 September 2017 Resolved
COI requires 4 total personnel with Fast Rescue Boat endorsements. Vessel has 3 personnel with that endorsement. Vessel is restricted to operations in Angola until deficiency is rectified and signed off by a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 October 2017
Resolution: master sent crew list and certs to CG ACTEUR as proof of compliance. Vessel can now operate outside of Angolan waters.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Bearing
Issued 4 November 2016 Resolved
Provide a class report attesting to the proper operation of the STBD drive. Vessel reported an overheating bearing in the stbd drive.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 16 November 2016
Resolution: Vessel provided a class report attesting to the proper operation of the stbd drive.
Stability › Watertight Integrity › General
Issued 17 October 2016 Resolved
Replace sponge gaskets on the following QAWTD, Bow thruster room, tank farm, drive gear room, steering gear room, steering gear room and emergency escape.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Stability › Watertight Integrity › General
Issued 17 October 2016 Resolved
Adjust the following following quick acting watertight scuttles, Bow thruster room, drive room emergency escape, steering gear room emergency escape.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 October 2016 Resolved
Adjust the following fire doors, Officers deck, crew deck, focsle deck, focsle deck head, main deck, mess deck, lounge, galley, chill/freezer, changing room, laundry room, switchboard room.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Engineering › Pressure Vessel › Relief Valve
Issued 17 October 2016 Resolved
Install a pressure relief valve on the water heater.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Discharge Hose
Issued 17 October 2016 Resolved
Replaced chaffed hose.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 17 October 2016 Resolved
Use lockout tagout as per SMS to secure U/V Purifier breaker
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 October 2016 Resolved
Install protective cover for J-box in the bow thruster room.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 17 October 2016 Resolved
Flammable liquids stored throughout the vessel and not in flame lockers.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 October 2016 Resolved
Secure freezer and refrigerator on mess deck.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 October 2016 Resolved
Install SOLAS stickers in accordance with fire and safety plan throughout the vessel.
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 22 November 2016
Resolution: Class report provided.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear/Clutch Starter (electric)
Issued 5 August 2015 Resolved
Provide proper operation of the emergency generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2015
Resolution: Starter was replaced and engine tested. All Sat.
Engineering › Steering Gear System › Pump
Issued 27 August 2014 Resolved
During inspection of steering gear, the port steering pumps #1 & #2 were both found to be leaking hydraulic fluid from the pump housing. Vessel is required to repair haydraulic leaks.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: Repair verified by ABS.
Engineering › Steering Gear System › Feedback Unit
Issued 27 August 2014 Resolved
Local rudder angle indicators were more than 5 degrees off from the readings on the bridge, also, the local indicator for the starboard rudder was sticking and then rapidly releasing to final rudder angle position. Vessel is required to demonstrate proper operation of rudder andle indicators.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: This issue has been converted to a condition of class per the ACP.
Engineering › Steering Gear System › Ram Seal
Issued 27 August 2014 Resolved
The port rudder was found to be continually hunting. Demonstrate proper operation of port steering gear in all operational modes, from all locations, including local control.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: Feeback issue was corrected and proper operation verified by ABS.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 August 2014 Resolved
Proper operation of the OWS could not be verified. Demonstrate proper operation of the OWS.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: ABS verified proper operation of OWS during annual survey.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 27 August 2014 Resolved
Vessels that cary NLSs as cargo shall maintain a cargo record book. Vessel carries CAT Y/Z cargoes and no cargo recorg book was onboard the vessel. Demonstrate that a cargo record book is being maintain onboard the vessel.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: ABS verified that vessel has been making proper entries and maintaining log book as required.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 August 2014 Resolved
Light fixtures on deck and located within the emergency escape trunk of the engine room port side were found to be broken. Replace broken light fixtures and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: Repaired/verified by ABS.
Communications › Alarms/Indicators › General Alarm
Issued 27 August 2014 Resolved
Alarm annunciaror was found hanging by the cable in the overhead near the port rudder in the steering room. Annunciator must be properly mounted.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: Repaired/verified by ABS.
Communications › Alarms/Indicators › Fire Alarm
Issued 27 August 2014 Resolved
During random test of heat/smoke detectors it was noted that the fire alarm bell located mid-tank room is not operational. Demonstrate the proper operation of the fire alrm bell.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: Fire alarm repaired/verified by ABS.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 August 2014 Resolved
The vessel's Periodic Safet Test Procedures do not contain the tests for required regulatory machinery alarms/shutdowns. Also, the required equipment to perform thses tests is not aboard the vessel. Vessel is required to revise PSTP to include these tests and provide equipment so the tests can be conducted on board.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 15 December 2014
Resolution: PSTP verified and approved by ABS. All necessary equipment for completing tests was brought on board and verified by ABS.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 7 February 2012 Resolved
Emergency generator does not have alarm arrangments for external high-pressure injection pumps jacketed piping. Received email 16 May 2012 confirming installation of alarms. Extended due date for verification at next attendance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2012
Resolved 26 November 2012
Resolution: Verified operation of new alarm.
Fire Fighting › Ventilation Systems › Fans
Issued 5 February 2012 Resolved
Replace and ensure proper function of stbd engine room supply fan and fire damper. Received email 2/6 that damper and fan in place. Left def open to be verified at next exam.
Condition: Improper/Lack of Maintenance
Due 7 November 2012
Resolved 27 March 2012
Resolution: ABS surveyor [name withheld] attended on behalf of ABS Europe to address outstanding defs. In SAFENET Report TK2123523 he reports this cleared.
Fire Fighting › Fire Main › Pressure
Issued 5 February 2012 Resolved
Install fire main pressure gauge at pilot house control station.
Condition: Improper Installation
Due 5 March 2012
Resolved 6 February 2012
Resolution: Received email screen shot of automation screen noting firemain pressure was included.
Fire Fighting › Fixed Deck Foam System › Foam Applicators
Issued 5 February 2012 Resolved
No foam analysis sample analyzed since 19 Aug 2010, vessel built/delivered in 2007, foam required to be analyzed in three years since onboard, and annually thereafter.
Condition: Improper/Lack of Maintenance
Due 5 March 2012
Resolved 10 April 2012
Resolution: Received report of new foam provided onboard and non-conformity report/corrective action.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 February 2012 Resolved
Lifesaving appliance maintenance is not in accordance with Rescue Boat and Launching Appliance manuals, no record procedures are being followed. Implement immediately, incorporate required maintenance into inplace maintenance program and submit Non-Conformity Corrective Action Report in 14 days. Received NCCAR, review maintenance at next inspection.
Condition: Improper/Lack of Maintenance
Due 7 November 2012
Resolved 26 November 2012
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 5 February 2012 Resolved
Repalce missing hammer from emergency quick closing valve station main deck, aft door to accomodations. Received email from Master 2/6/2012 that key and lanyard put in place instead. Left def open to be verifed at next exam.
Condition: Improper/Lack of Maintenance
Due 7 November 2012
Resolved 27 March 2012
Resolution: ABS surveyor [name withheld] attended on behalf of ABS Europe to address outstanding defs. In SAFENET Report TK2123523 he reports this cleared.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 5 February 2012 Resolved
Provide flange shielding for fuel oil piping in p-tank room as required downstream of discharge and transfer pumps. Received email clearing def, extended to verify at next attendance.
Condition: Improper Installation
Due 7 November 2012
Resolved 27 March 2012
Resolution: ABS surveyor [name withheld] attended on behalf of ABS Europe to address outstanding defs. In SAFENET Report TK2123523 he reports this cleared.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 5 February 2012 Resolved
Replace missing section of A-60 structural fire protection in stbd deck store room (in way of CO2 and e-gen spaces). Prove CG approval if new material used. Received email clearing def, extended to verify at next attendance.
Condition: Improper/Lack of Maintenance
Due 7 November 2012
Resolved 27 March 2012
Resolution: ABS surveyor [name withheld] attended on behalf of ABS Europe to address outstanding defs. In SAFENET Report TK2123523 he reports this cleared.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 February 2012 Resolved
Clear trouble alarms in fire detection panel, noting trouble alarms with smoke detector in engine room and P-tank room.
Condition: Improper/Lack of Maintenance
Due 19 February 2012
Resolved 27 March 2012
Resolution: ABS surveyor [name withheld] attended on behalf of ABS Europe to address outstanding defs. In SAFENET Report TK2123523 he reports this cleared.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 5 February 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 7 November 2012
Resolved 27 March 2012
Resolution: ABS surveyor [name withheld] attended on behalf of ABS Europe to address outstanding defs. In SAFENET Report TK2123523 he reports this cleared.
Documentation › Certificates/Documents › Certificate of Fitness (OSVs)
Issued 5 February 2012 Resolved
Vessel is enrolled in ACP, with ABS. Vessel to replace CG issued IOPP NLS with Certificate of Fitness for carriage of limited quantities of NLS (A.673) now that ABS has received authorization.
Condition: Invalid
Due 7 November 2012
Resolved 19 December 2012
Resolution: Copy of cert emailed from ABS
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 5 February 2012 Resolved
Prove thorough testing of all vital system automation periodic safety test procedures.
Condition: Improper/Lack of Maintenance
Due 5 March 2012
Resolved 27 March 2012
Resolution: ABS surveyor [name withheld] attended on behalf of ABS Europe to address outstanding defs. In SAFENET Report TK2123523 he reports this cleared.
Documentation › Logs/Records › Logbook (official)
Issued 5 February 2012 Resolved
Vessel is not conducting drills and inspections in accordance with 46 CFR 131,Subpart E. Emergency generator must be tested at least 2 hours under load, at least once a month. To be verified at next inspection.
Condition: Improper Installation
Due 7 November 2012
Resolved 26 November 2012
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 27 August 2008 Resolved
The SOPEP does not contain a list of coastal state administrations as required by reg 33 CFR 155.26(b)(6).
Due 27 September 2008
Resolved 27 February 2009
Resolution: SOPEP deactivated by plan holder. Vessel approved in Seacor Marine LLC SMPEP.
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 13 April 2008 Resolved
VSL experienced a throttle failure while transitting in vicinity of MM 46 LMR. Provide detailed repair report of the causual factors and prove proper operation to class (ABS). ABS surveyor may clear this defficiency IAW NVIC 02-95.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 14 April 2008
Resolution: Problem was found to be a faulty UPS for the 24V system.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 November 2007 Resolved
Due to various name changes on COD, the statutory documents were not harmonized with vessel and COD. Harmonize within the next 30 Days to reflect the name JOHN COGHILL.
Action required: 705 - Other - as specified
Due 8 December 2007
Resolved 29 February 2008
Resolution: Sighted Certificate of Documentation with correct vessel name. Issued amended COI with correct vessel name.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 7 November 2007 Resolved
Provide an approved Non Tank Vessel Response Plan and add it to the approved SMPEP in accordance with 33 CFR 1015.
Action required: 705 - Other - as specified
Due 8 December 2007
Resolved 20 August 2008

Casualty record · 2

12 April 2008Routine · role: Involved in a Marine Casualty · activity 3183710
4 November 2016Routine · role: Involved in a Marine Casualty · activity 6035050
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.