MAURY USCG vessel records Sign in
← All vessels

FLORENCE

FLORENCE is a 2006 tank ship. The Coast Guard has recorded 15 inspections since 2007, most recently in April 2025, along with 7 deficiencies.

Records from 2007 to 2025. Most recent: inspection, 18 April 2025.

Built
2006
Last inspected
18 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9333242 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
880780
Flag
PANAMA
—
Maury page id
psix-880780

Inspections, by type

…with no type recorded2
Years with a record 12 calendar years (2007–2025)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it47999 - Dead Weight, Ton
57342 - Displacement, Ton
28844 - Convention (Subpart B), Gross Ton
12962 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

18 April 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8113768
10 January 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7844193
5 January 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7613688
14 November 2019 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6853390
17 December 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6594303
3 November 2017 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6299587
15 November 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6040419
21 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5801052
30 October 2015 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5754014
23 October 2014 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5008558
11 April 2009 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3450516
31 March 2008 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3174907
21 May 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2936103
27 April 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2916721
26 April 2007 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2915853

Deficiency record · 7

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 January 2023 Resolved
AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE TO THE MACHINERY AND EQUIPMENT WITHOUT THE SANCTION OF THE ADMINISTRATION. MULTIPLE UNAPPROVED REPAIRS ON PORT AND STBD ANCHOR WASH PIPING WERE FOUND, WITH NO DOCUMENTATION FROM CLASS. 74 SOLAS (2020 ED.) I/11(B)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2023
Resolution: Received survey for condition of Class. See Def documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 14 November 2019 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 mm (.5 inch) diameter and is at least 25.4 mm (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. Permanent studs at the fwd vapor line on the port side manifold and the aft vapor line on the starboard manifold were missing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 November 2019
Resolution: Vessel provided pictures of repairs.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 27 April 2007 Resolved
Mixed garbage was found in various parts of the vessel. Also the garbage plan did not address the disposal of medicines, batteries or containment of ash. All of these items were being kept on board and segregated but they have not been identified in their plan.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 27 April 2007
Resolution: Changes were being made to the plan to include the items listed. The plan will be sent off to the management company for approval.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 April 2007 Resolved
The Sewage System is not being maintained as per the manufacturer's requirements. Weekly inspection are not being done.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 27 April 2007
Resolution: Changes were being made to the plan to include the items listed. The plan will be sent off to the management company for approval.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 27 April 2007 Resolved
The cargo and bunker transfer procedures were not in accordance with the Code of Federal Regulations.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 27 April 2007
Resolution: Copies of the regulations were given to the Master and [name withheld] were being made to the ship''s plan to include the items listed as per 33 CFR.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 April 2007 Resolved
Controlled drugs were found in the refrigerator in the hospital space. The door to the refrigerator was not locked. According to the World Health Organization the recommendation is that the drugs (Atropine) should be kept refrigerated. The drugs were taken out and placed in the Captain’s safe until the ship's crew can place a hasp and lock on the door, ILO 147.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 27 April 2007
Resolution: The drugs were removed and a hasp and lock will be placed on the refrigerator door.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 27 April 2007 Resolved
The Ballast Water Management Plan is not ship specific. The plan is a mixture of items form the IMO Res. 868 (20), and incorporating items relating to the ship. But it doesn’t come close to being ship specific. Crew training is not being done, safety measures of when not to exchange ballast have not been addressed and the specific number of tanks or pumps are not listed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 May 2007
Resolution: Received a copy of the ship''s specific BWM plan from the company superintendent.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.