MAURY USCG vessel records
← All vessels

FLORENCE

FLORENCE is a 2006 tank ship. The Coast Guard has recorded 8 inspections since 2016, most recently in April 2025, along with 2 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 18 April 2025.

Built
2006
Last inspected
18 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9333242
880780
Flag
PANAMA
Maury page id
psix-880780

Documentation record

Tonnage as PSIX records it47999 - Dead Weight, Ton
57342 - Displacement, Ton
28844 - Convention (Subpart B), Gross Ton
12962 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

8 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

18 April 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8113768
10 January 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7844193
5 January 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7613688
14 November 2019 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6853390
17 December 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6594303
3 November 2017 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6299587
15 November 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6040419
21 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5801052

Deficiency record · 2

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 January 2023 Resolved
AFTER ANY SURVEY OF THE SHIP HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE TO THE MACHINERY AND EQUIPMENT WITHOUT THE SANCTION OF THE ADMINISTRATION. MULTIPLE UNAPPROVED REPAIRS ON PORT AND STBD ANCHOR WASH PIPING WERE FOUND, WITH NO DOCUMENTATION FROM CLASS. 74 SOLAS (2020 ED.) I/11(B)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2023
Resolution: Received survey for condition of Class. See Def documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 14 November 2019 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 mm (.5 inch) diameter and is at least 25.4 mm (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. Permanent studs at the fwd vapor line on the port side manifold and the aft vapor line on the starboard manifold were missing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 November 2019
Resolution: Vessel provided pictures of repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.