WESTERN HIGHWAY is a 2007 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in May 2026, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: operational control imposed, 5 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it39422 - Regulatory (Subpart C or D), Gross Ton 24427 - Displacement, Ton 11827 - Regulatory (Subpart C or D), Net Ton 39422 - Convention (Subpart B), Gross Ton 12980 - Dead Weight, Ton 11827 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
5 May 2026Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8367568
26 March 2026PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8329329
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 14 August 2019Resolved
04102 - Emergency Fire Pump and its Pipes - Fire-extinguishing appliances shall be readily available. The evergency fire pump is inoperable.
74 SOLAS (2004) II-2/10.1.2 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
Resolution: Vessel overhauled the emergency fire pump and replaced two mouth rings. Operational test of the emergency fire pump conducted, All SAT. Repairs have been completed to the satisfactory of NKK, see Class Report No. 19ST0098 for further details.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 August 2019Resolved
07113 - Fire Pumps and its Pipes - The machinery, boilers and other pressure vessels, associated pipping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The fire and G.S pump is currently leaking water at a rate of one drip every five seconds when not energized, and sprays water constantly while energized.
74 SOLAS (2014) II-1/26.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
Resolution: Vessel replaced the wasted mechanical shaft seal. The vessel conducted an operational test of the Fire and General Service pumps, All SAT. Repairs have been completed to the satisfactory of NKK, see Class Report No. 19ST0098 for further details.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 August 2019Resolved
06199 - Other (cargo) - There shall be provided an effective power ventilation system sufficient to give at least the following air changes: 6 per hour. The vessels cargo ventilation system unexpectedly stopped working for roughly 45 minutes. The vessels crew was unable to identify the cause of the failure to the ventilation system.
74 SOLAS (2004) II-2/20.3.1.1.2 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
Resolution: Class surveyor verified the full operational control of the cargo space ventilation system. System has been accepted to be fully operational, All SAT. Operational test has been reviewed and approved to the satisfactory of NKK, see Class Report No. 19ST009
1510-Navigation Equipment - The condition of the ship shall be maintained to ensure it will remain safe to proceed to sea without danger to the ship or its crew. While operating steering pump #1 in non follow up mode, the rudder drifts slowly to the port side. 74SOLAS(14)I/II(a) 40ac.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2016
Resolution: RECEIVED SATISFACTORY REPORT FROM CLASS STATING REPAIRS WERE MADE.