Records from 2016 to 2026. Most recent: inspection, 19 February 2026.
Inspection history · 16
19 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8312121
19 February 2025
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8078470
4 November 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8029698
22 February 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7868848
26 April 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7689299
7 June 2022
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7471228
29 March 2022
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7420478
14 January 2021
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7121689
9 March 2020
COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6923185
4 March 2020
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6920425
24 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6761009
15 August 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6506766
22 May 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6417527
12 June 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6173706
27 July 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5954404
4 May 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5868986
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 February 2026
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction...
MIs observed the #6 and #7 port side stanchion posts from the bow are loose and must be tightened down to the deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2026
Resolution: #6 and #7 port side stanchion posts from the bow were tightened down to the deck.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 February 2025
Resolved
The owner, charterer, master or managing operator shall instruct each crew member... Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information.(1) Date of the training; and(2) General description of the training topics. Log books do not provide who conducted training/drills and do not discuss drill scenarios and training topics.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: New log created and being utilized
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 19 February 2025
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass did not have a light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: New compass with light installed
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 19 February 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Escape hatch not properly labeled on both sides.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: Proper making installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 February 2025
Resolved
Watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT HATCH—KEEP CLOSED”. Watertight hatches are not properly labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: Proper marking installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Containers for life jackets are not properly labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: Proper marking installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Container for child life jackets is not appropriately marked and does not separate child and adult.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: Proper marking installed with seperations of adult/child life jackets
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 February 2025
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Watertight hatches missing attaching device.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: Cable installed to attach hatches
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter. The grab line shall ... having a minimum breaking strength of 1,350 pounds. Grab line of life ring is wasted and frayed by twisting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: New life roing installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2025
Resolved
Where a flexible fill pipe section is necessary,... When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Fuel fill missing conductor.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 13 March 2025
Resolution: Ground wire installed from tank fill to tank
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 February 2025
Resolved
The float-free link required by § 180.130(a)(1) for survival craft must be:(1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant;(2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Float free link missing identification tag.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: New float free link installed with tag.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 February 2025
Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Paddles were not lashed to the life float.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: Paddles new lashed with Velcro
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 19 February 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not mounted and were incomplete.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2025
Resolved 12 March 2025
Resolution: Emergency instructions posted as required
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 March 2020
Resolved
Submit repair plan for rotting stringer in fwd compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2020
Resolved 9 March 2020
Resolution: replaced all rotted stringers with new wood.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 August 2018
Resolved
Epirb Expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 30 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 August 2018
Resolved
Hydrostatic Release Unit Expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 30 August 2018
Communications › Radio Communications › EPIRB
Issued 1 August 2016
Resolved
EPIRB battery expired. Replace with new.
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 1 August 2016
Resolution: Vessel provided proof of new battery and replaced expired one.
Communications › Radio Communications › EPIRB
Issued 1 August 2016
Resolved
Hydrostatic release for EPIRB expiration date is unavailable. Replace with new.
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 1 August 2016
Resolution: Vessel provided proof of new hydrostatic release and installed same.
Lifesaving › Lifefloat › Paddle
Issued 1 August 2016
Resolved
Life float does not have required 2 oars.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 1 August 2016
Resolution: Vessel provided proof of purchasing 2- oars and outfitting onboard life float with them.