MAURY USCG vessel records
← All vessels

CMA CGM SAN FRANCISCO

CMA CGM SAN FRANCISCO is a 2001 freight ship. The Coast Guard has recorded 26 inspections since 2018, most recently in August 2024, along with 10 deficiencies and 8 operational controls.

Records from 2018 to 2024. Most recent: inspection, 3 August 2024.

Built
2001
Last inspected
3 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 August 2024
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2018–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9225615
881567
Flag
LIBERIA
Maury page id
psix-881567

Documentation record

Tonnage as PSIX records it75590 - Convention (Subpart B), Gross Ton
85824 - Dead Weight, Metric Ton
112640 - Displacement, Metric Ton
42233 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

3 August 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7973408
11 June 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7932342
2 June 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7921260
19 October 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7809715
27 March 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7657477
4 November 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7589414
5 August 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7524776
17 May 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7455245
25 January 2022 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7381988
18 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7382063
22 November 2021 Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7353026
7 November 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7346740
20 May 2021 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7202541
22 April 2021 Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7177443
22 April 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7210392
11 July 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7003272
3 June 2020 PSC B · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6963942
30 May 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6963941
3 May 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6947468
22 April 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6942183
21 March 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6929923
18 March 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6928446
18 March 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6929035
15 March 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6926764
14 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6926454
8 December 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6590924

Deficiency record · 10

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 2 June 2024 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices. A second source of energy shall be provided for an additional three starts. PSCO observed hydrualic means of start for emergency generator was inop SOLAS (Cons 2004) II-1/44.2
Action required: 10 - Deficiency Rectified
Due 2 June 2024
Resolved 2 June 2024
Resolution: PSCO observed crew fix closed spring valve on e-generator. PSCO observed operation of e-generator started via hydraulic means of start.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 22 November 2021 Resolved
Under all sailing conditions, including maneuvering, the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable from the navigation bridge. Vessel reported that the bridge control of the propulsion machinery was not operational. Vessel may shift to lay berth permitted with no fewer than 2 tugs. Assisting tugs must be of adequate horsepower and sufficient quantity to satisfy attending pilot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 December 2021
Resolved 25 January 2022
Resolution: Reviewed documents from class showing deficiency had been rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Electrical installations shall be such that all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions will be ensured without recourse to emergency source of power. PSCO observed an electrical ground on the 220V switchboard in the engine control room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 April 2021
Resolution: PSCO observed fix of ground.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched. Emergency Transformer breakers did not have a mechanical interlock causing potential for injury.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2021
Resolved 20 May 2021
Resolution: Received class report/ proper documentation from Class DNV stating all outstanding deficiencies have been rectified. Mechanical interlock was replaced to satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 April 2021 Resolved
After any survey of the ship has been completed, no change shall be made in structural arrangements, machinery, equipment an other items covered by survey without sanction of administration. PSCO observed an unauthorized repair of fire main in the BOSUN Locker.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 5 May 2021
Resolution: Received class report/ proper documentation from Class DNV stating all outstanding deficiencies have been rectified. Fire main in BOSUN Locker was repaired to satisfaction of class.
09 - Working and Living Conditions › 091 - Living Conditions › Cold room
Issued 22 April 2021 Resolved
After any survey of the ship has been completed, no change shall be made in structural arrangements, machinery, equipment an other items covered by survey without sanction of administration. PSCO observed excessive ice vaccumulation in the fish and meat reefer flat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 30 May 2021
Resolution: PSC NOLA received class report from DNV satisfying the requirement.
09 - Working and Living Conditions › 091 - Living Conditions › Cold room
Issued 22 April 2021 Resolved
After any survey of the ship has been completed, no change shall be made in structural arrangements, machinery, equipment, and other items covered by the survey, without sanction of the Administration. PSCO observed excessive ice accumulation in the fish and meat reefer flat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2021
Resolved 30 May 2021
Resolution: repaired to close tight; new rubber packing/material was ordered for final repairs at a later date.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 December 2018 Resolved
Arrangements for use of lube oil systems shall be such as to ensure safety of ship and persons on board. Lube oil inlet valve to lube oil cooler is actively leaking, causing a significant fire hazard. 74 SOLAS (01 Cons.) II-2.15.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2018
Resolved 8 December 2018
Resolution: Received classification document from DNB GL attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 December 2018 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The port side life boat was not able to be recovered. 74 SOLAS (14 Cons.) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2018
Resolved 15 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 December 2018 Resolved
Manholes and flush shuttles shall be closed by substantial covers capable of being made water-tight. Engine room hatches had gaskets no gaskets to maintain water tightness. ICLL 66 I/18.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2018
Resolved 8 December 2018
Resolution: Received classification document from DNV GL attesting to repairs.

Ownership record