SIR JOSIE T

SIR JOSIE T is a 1965 towing vessel. The Coast Guard has recorded 19 inspections since 1996, most recently in June 2026, along with 33 deficiencies.

Records from 1996 to 2026. Most recent: inspection, 24 June 2026.

Built
1965
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 24 June 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 12 calendar years (1996–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL3677
Flag
UNITED STATES
Maury page id
psix-88179

Documentation record

Registered dimensions (L × B × D)52.0 ft × 21.2 ft × 6.1 ft
Registered tonnagegross 58 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUMBOLDT BOAT SERVICE · ST LOUIS, MO, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 October 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
40 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

24 June 2026 Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8413759
3 June 2025 Administrative Inspection · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8136523
7 May 2025 Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8130175
5 December 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7829878
18 April 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7671501
16 March 2022 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7417561
17 March 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7162567
28 April 2020 Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6944981
15 April 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6941739
24 February 2020 Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6914359
26 April 2017 Examination of Repairs · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6132813
2 July 2012 Administration · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4368226
12 November 2008 Uninspected Other · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3364522
27 September 2006 Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2787877
25 September 2006 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2815978
10 March 1998 Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 413608
5 February 1998 Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 412542
25 January 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659062
18 January 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 387023

Deficiency record · 33

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 March 2020 Resolved
Vessel must have handrails or equivalent around all weather decks accessible to crew-members. Vessel currently has an unprotected aft deck and foredeck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2020
Resolved 15 April 2020
Resolution: Vessel installed satisfactory chain handrails around decks.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 12 November 2008 Resolved
Prove proper operation of the installed engine room heat detection system. System needs to be serviced or repaired by an NFPA approved fire maintenance company. (Still need to provide proof that heat detection system was certified by a Reregistered Professional Engineer as per 46CFR27.203(g)).
Condition: Improper/Lack of Maintenance
Due 13 January 2009
Resolved 28 January 2009
Fire Fighting › Nozzles › Type
Issued 12 November 2008 Resolved
Ensure the vessel has an approved, 1.5 inch, vari-nozzle for the portable fire pump.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 November 2008 Resolved
Ensure the vessel’s official number (ON. 501258) is permanently affixed to the interior portion of the vessel in three inch minimum size letters.
Condition: Unknown
Due 13 January 2009
Resolved 28 January 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 12 November 2008 Resolved
Ensure the vessel’s Master has a current FCC restricted radio operators permit and TWIC. The TWIC is not required until 15April09.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Operations/Management › Drills/Instruction › Fire
Issued 12 November 2008 Resolved
Document (can use pre-start up check-off sheet) monthly man overboard and fire fighting drills.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Communications › Alarms/Indicators › General Alarm
Issued 12 November 2008 Resolved
Document weekly testing of the vessel’s general alarm bell.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008 Resolved
Properly support (as necessary) all interior wires. Wires need to be secured with metal supports every 24 inches.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Communications › Alarms/Indicators › General Alarm
Issued 12 November 2008 Resolved
Ensure the general alarm indicator light in the engineroom is RED.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 November 2008 Resolved
Properly blanket (with approved insulation) all engine dry exhausts.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008 Resolved
Either place back in service or ensure the electrical power is secured to the forward main deck exterior light.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Stability › Unintentional Flooding › General
Issued 12 November 2008 Resolved
Service the rudder post bearings and bushings to prevent water infiltration in the stern void.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008 Resolved
Properly wire the portside, transfer pump. Ensure wiring is explosive proof.
Condition: Improper/Lack of Maintenance
Due 13 January 2009
Resolved 28 January 2009
Accommodation/Occupational Safety › Ventilation › General
Issued 12 November 2008 Resolved
Clean the generators housing screens.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Fuse
Issued 12 November 2008 Resolved
Guard or cover the exposed generator battery shut off switch.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008 Resolved
Remove abandoned wires (currently cut) above the generator, stbd side.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008 Resolved
Properly wire the port bow winch.
Condition: Improper/Lack of Maintenance
Due 13 January 2009
Resolved 28 January 2009
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 12 November 2008 Resolved
Cover the exposed, winch, electrical relay box located on the stbd side of the work area.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 November 2008 Resolved
Blank off all open electrical box penetrations.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008 Resolved
Properly support the junction box and remove the abandoned wire, stbd side, outboard, main diesel engine.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 November 2008 Resolved
Ensure all portable fire extinguishers are properly secured in approved brackets.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 12 November 2008 Resolved
Install a drain plug for the vessel’s port and stbd side fuel fill containment.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 November 2008 Resolved
Install a light for the vessel’s compass.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008 Resolved
Ensure the fuel transfer hose is hydrostatically tested annually to at least 100 psi as per 33CFR.156.170.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008 Resolved
Provide documentation that the transfer hose has a burst pressure of at least 260 psi and date of manufacture as per 33CFR.154.500.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008 Resolved
Verify the transfer station relief valve is tested annually as per 33CFR.156.170.
Condition: Unknown
Due 13 January 2009
Resolved 28 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008 Resolved
Verify the transfer station piping has a pressure gauge installed and that it is tested annually to verify its accuracy to within 10% as per 33CFR.156.170.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008 Resolved
Ensure the transfer hose is marked for (OIL SERVICE ONLY) as per 33CFR.154.500.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 November 2008 Resolved
Ensure the company’s chemical testing program meets the requirements of 46CFR16 prior to operating the vessel.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2009
Resolved 29 January 2009
Documentation
Issued 18 January 1996 Resolved
AN OIL DISCHARGE PLACARD WAS NOT POSTED ON THE VESSEL.
Condition: Unknown
Due 18 February 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 18 January 1996 Resolved
A POLLUTION PREVENTION PLACARD WAS NOT POSTED ON THE VESSEL.
Condition: Unknown
Due 18 February 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 January 1996 Resolved
THE WORK VESTS WERE NOT STOWED SEPARATELY FROM THE LIFEJACKETS.
Condition: Unknown
Due 19 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 18 January 1996 Resolved
THE OFFICIAL NUMBER WAS NOT PERMANENTLY AFFIXED TO AN INTERIOR STRUCTURAL PART OF THE HULL.
Condition: Unknown
Due 18 February 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.