Records from 1996 to 2026. Most recent: inspection, 24 June 2026.
Inspection history · 19
24 June 2026
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8413759
3 June 2025
Administrative Inspection · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8136523
7 May 2025
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8130175
5 December 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7829878
18 April 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7671501
16 March 2022
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7417561
17 March 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7162567
28 April 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6944981
15 April 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6941739
24 February 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6914359
26 April 2017
Examination of Repairs · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6132813
2 July 2012
Administration · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4368226
12 November 2008
Uninspected Other · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3364522
27 September 2006
Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2787877
25 September 2006
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2815978
10 March 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 413608
5 February 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 412542
25 January 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659062
18 January 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 387023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 March 2020
Resolved
Vessel must have handrails or equivalent around all weather decks accessible to crew-members. Vessel currently has an unprotected aft deck and foredeck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2020
Resolved 15 April 2020
Resolution: Vessel installed satisfactory chain handrails around decks.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 12 November 2008
Resolved
Prove proper operation of the installed engine room heat detection system. System needs to be serviced or repaired by an NFPA approved fire maintenance company. (Still need to provide proof that heat detection system was certified by a Reregistered Professional Engineer as per 46CFR27.203(g)).
Condition: Improper/Lack of Maintenance
Due 13 January 2009
Resolved 28 January 2009
Fire Fighting › Nozzles › Type
Issued 12 November 2008
Resolved
Ensure the vessel has an approved, 1.5 inch, vari-nozzle for the portable fire pump.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 November 2008
Resolved
Ensure the vessel’s official number (ON. 501258) is permanently affixed to the interior portion of the vessel in three inch minimum size letters.
Condition: Unknown
Due 13 January 2009
Resolved 28 January 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 12 November 2008
Resolved
Ensure the vessel’s Master has a current FCC restricted radio operators permit and TWIC. The TWIC is not required until 15April09.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Operations/Management › Drills/Instruction › Fire
Issued 12 November 2008
Resolved
Document (can use pre-start up check-off sheet) monthly man overboard and fire fighting drills.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Communications › Alarms/Indicators › General Alarm
Issued 12 November 2008
Resolved
Document weekly testing of the vessel’s general alarm bell.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly support (as necessary) all interior wires. Wires need to be secured with metal supports every 24 inches.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Communications › Alarms/Indicators › General Alarm
Issued 12 November 2008
Resolved
Ensure the general alarm indicator light in the engineroom is RED.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 November 2008
Resolved
Properly blanket (with approved insulation) all engine dry exhausts.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Either place back in service or ensure the electrical power is secured to the forward main deck exterior light.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Stability › Unintentional Flooding › General
Issued 12 November 2008
Resolved
Service the rudder post bearings and bushings to prevent water infiltration in the stern void.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly wire the portside, transfer pump. Ensure wiring is explosive proof.
Condition: Improper/Lack of Maintenance
Due 13 January 2009
Resolved 28 January 2009
Accommodation/Occupational Safety › Ventilation › General
Issued 12 November 2008
Resolved
Clean the generators housing screens.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Fuse
Issued 12 November 2008
Resolved
Guard or cover the exposed generator battery shut off switch.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Remove abandoned wires (currently cut) above the generator, stbd side.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly wire the port bow winch.
Condition: Improper/Lack of Maintenance
Due 13 January 2009
Resolved 28 January 2009
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 12 November 2008
Resolved
Cover the exposed, winch, electrical relay box located on the stbd side of the work area.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 November 2008
Resolved
Blank off all open electrical box penetrations.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly support the junction box and remove the abandoned wire, stbd side, outboard, main diesel engine.
Condition: Improper/Lack of Maintenance
Due 12 December 2008
Resolved 6 January 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 November 2008
Resolved
Ensure all portable fire extinguishers are properly secured in approved brackets.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 12 November 2008
Resolved
Install a drain plug for the vessel’s port and stbd side fuel fill containment.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 November 2008
Resolved
Install a light for the vessel’s compass.
Condition: Placed in Improper Service
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Ensure the fuel transfer hose is hydrostatically tested annually to at least 100 psi as per 33CFR.156.170.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Provide documentation that the transfer hose has a burst pressure of at least 260 psi and date of manufacture as per 33CFR.154.500.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Verify the transfer station relief valve is tested annually as per 33CFR.156.170.
Condition: Unknown
Due 13 January 2009
Resolved 28 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Verify the transfer station piping has a pressure gauge installed and that it is tested annually to verify its accuracy to within 10% as per 33CFR.156.170.
Condition: Unknown
Due 12 December 2008
Resolved 6 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Ensure the transfer hose is marked for (OIL SERVICE ONLY) as per 33CFR.154.500.
Condition: Placed in Improper Service
Due 13 January 2009
Resolved 28 January 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 November 2008
Resolved
Ensure the company’s chemical testing program meets the requirements of 46CFR16 prior to operating the vessel.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2009
Resolved 29 January 2009
Documentation
Issued 18 January 1996
Resolved
AN OIL DISCHARGE PLACARD WAS NOT POSTED ON THE VESSEL.
Condition: Unknown
Due 18 February 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 18 January 1996
Resolved
A POLLUTION PREVENTION PLACARD WAS NOT POSTED ON THE VESSEL.
Condition: Unknown
Due 18 February 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 January 1996
Resolved
THE WORK VESTS WERE NOT STOWED SEPARATELY FROM THE LIFEJACKETS.
Condition: Unknown
Due 19 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 18 January 1996
Resolved
THE OFFICIAL NUMBER WAS NOT PERMANENTLY AFFIXED TO AN INTERIOR STRUCTURAL PART OF THE HULL.
Condition: Unknown
Due 18 February 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past