SIR JOSIE T
SIR JOSIE T is a 1965 towing vessel. The Coast Guard has recorded 19 inspections since 1996, most recently in June 2026, along with 33 deficiencies.
Records from 1996 to 2026. Most recent: inspection, 24 June 2026.
- Built
- 1965
- Last inspected
- 24 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 33 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
501258
WDL3677
88179
Flag
UNITED STATES
367082420, 368123950
Maury page id
psix-88179
Inspections, by type
…with no type recorded5
Years with a record
12 calendar years (1996–2026)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)52.0 ft × 21.2 ft × 6.1 ft
Registered tonnagegross 58 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUMBOLDT BOAT SERVICE · ST LOUIS, MO, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 October 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
40 - Regulatory (Subpart C or D), Net Ton
40 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL3677MMSI 368123950 · active · compulsorily equipped · granted 13 December 2019, expires 13 December 2029
WDJ5201MMSI 367082420 · active · voluntarily equipped · granted 28 April 2017, expires 28 April 2027 · licensed under a name not among this hull’s recorded names (not shown)
WCV9943MMSI 367082420 · expired · compulsorily equipped · granted 20 December 2005, cancelled 30 April 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 19
24 June 2026
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8413759
3 June 2025
Administrative Inspection · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8136523
7 May 2025
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8130175
5 December 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7829878
18 April 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7671501
16 March 2022
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7417561
17 March 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7162567
28 April 2020
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6944981
15 April 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6941739
24 February 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6914359
26 April 2017
Examination of Repairs · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6132813
2 July 2012
Industry Initiated Exam · Administration · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4368226
12 November 2008
Uninspected Other · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3364522
27 September 2006
Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2787877
25 September 2006
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2815978
10 March 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 413608
5 February 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 412542
25 January 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659062
18 January 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 387023
Deficiency record · 33
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 March 2020
Resolved
Vessel must have handrails or equivalent around all weather decks accessible to crew-members. Vessel currently has an unprotected aft deck and foredeck.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 12 November 2008
Resolved
Prove proper operation of the installed engine room heat detection system. System needs to be serviced or repaired by an NFPA approved fire maintenance company. (Still need to provide proof that heat detection system was certified by a Reregistered Professional Engineer as per 46CFR27.203(g)).
Fire Fighting › Nozzles › Type
Issued 12 November 2008
Resolved
Ensure the vessel has an approved, 1.5 inch, vari-nozzle for the portable fire pump.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 November 2008
Resolved
Ensure the vessel’s official number (ON. 501258) is permanently affixed to the interior portion of the vessel in three inch minimum size letters.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 November 2008
Resolved
Ensure the vessel’s Master has a current FCC restricted radio operators permit and TWIC. The TWIC is not required until 15April09.
Operations/Management › Drills/Instruction › Fire
Issued 12 November 2008
Resolved
Document (can use pre-start up check-off sheet) monthly man overboard and fire fighting drills.
Communications › Alarms/Indicators › General Alarm
Issued 12 November 2008
Resolved
Document weekly testing of the vessel’s general alarm bell.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly support (as necessary) all interior wires. Wires need to be secured with metal supports every 24 inches.
Communications › Alarms/Indicators › General Alarm
Issued 12 November 2008
Resolved
Ensure the general alarm indicator light in the engineroom is RED.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 November 2008
Resolved
Properly blanket (with approved insulation) all engine dry exhausts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Either place back in service or ensure the electrical power is secured to the forward main deck exterior light.
Stability › Unintentional Flooding › General
Issued 12 November 2008
Resolved
Service the rudder post bearings and bushings to prevent water infiltration in the stern void.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly wire the portside, transfer pump. Ensure wiring is explosive proof.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 November 2008
Resolved
Clean the generators housing screens.
Electrical › Electrical Distribution System (service) › Fuse
Issued 12 November 2008
Resolved
Guard or cover the exposed generator battery shut off switch.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Remove abandoned wires (currently cut) above the generator, stbd side.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly wire the port bow winch.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 12 November 2008
Resolved
Cover the exposed, winch, electrical relay box located on the stbd side of the work area.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 November 2008
Resolved
Blank off all open electrical box penetrations.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Properly support the junction box and remove the abandoned wire, stbd side, outboard, main diesel engine.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 November 2008
Resolved
Ensure all portable fire extinguishers are properly secured in approved brackets.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 12 November 2008
Resolved
Install a drain plug for the vessel’s port and stbd side fuel fill containment.
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 November 2008
Resolved
Install a light for the vessel’s compass.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Ensure the fuel transfer hose is hydrostatically tested annually to at least 100 psi as per 33CFR.156.170.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Provide documentation that the transfer hose has a burst pressure of at least 260 psi and date of manufacture as per 33CFR.154.500.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Verify the transfer station relief valve is tested annually as per 33CFR.156.170.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Verify the transfer station piping has a pressure gauge installed and that it is tested annually to verify its accuracy to within 10% as per 33CFR.156.170.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 12 November 2008
Resolved
Ensure the transfer hose is marked for (OIL SERVICE ONLY) as per 33CFR.154.500.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 November 2008
Resolved
Ensure the company’s chemical testing program meets the requirements of 46CFR16 prior to operating the vessel.
Documentation
Issued 18 January 1996
Resolved
AN OIL DISCHARGE PLACARD WAS NOT POSTED ON THE VESSEL.
Accommodation/Occupational Safety
Issued 18 January 1996
Resolved
A POLLUTION PREVENTION PLACARD WAS NOT POSTED ON THE VESSEL.
Lifesaving
Issued 18 January 1996
Resolved
THE WORK VESTS WERE NOT STOWED SEPARATELY FROM THE LIFEJACKETS.
Documentation
Issued 18 January 1996
Resolved
THE OFFICIAL NUMBER WAS NOT PERMANENTLY AFFIXED TO AN INTERIOR STRUCTURAL PART OF THE HULL.