MAURY USCG vessel records Sign in
← All vessels

RICHARD A SMITH

RICHARD A SMITH is a 2006 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2005, most recently in September 2026, along with 16 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2012.

Records from 2005 to 2026. Most recent: inspection, 8 September 2026.

Built
2006
Last inspected
8 September 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE4712
881878
Flag
UNITED STATES
—
Maury page id
psix-881878

Inspections, by type

…with no type recorded1
Years with a record 14 calendar years (2005–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INTERNATIONAL BOAT WORKS INC. · FT PIERCE AND DELEON SPRINGS, FL, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBUFFALO, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

8 September 2026 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8486386
11 September 2025 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8231626
11 September 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8000797
25 October 2022 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7583494
14 September 2022 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7557704
2 August 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7288140
13 July 2021 Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7253508
17 June 2020 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6980746
20 August 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6788509
13 November 2018 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6605715
18 October 2017 Hull Examination · Internal Structural Exam · COI Inspection · DAPI Audit · In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6280675
19 September 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6450341
26 July 2017 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6221335
2 August 2016 DAPI Audit · Annual Inspection · Plan Review "T" Boat · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5944778
12 July 2012 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4376161
16 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4209460
12 July 2007 Initial Certification · Simplified Stability Test · Plan Review "T" Boat · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3001351
29 August 2005 Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2478668
3 August 2005 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2450543

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 September 2026 No resolution recorded
A vessel on a Great Lakes route must carry six hand red flares and six hand orange smoke distress signals. Vessel did not have 12 distress signals. Vessel is restricted to daylight only operations and short runs limited to approximately 30 minutes away from the dock.
Due 8 October 2026
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 July 2021 Resolved
Portable fire extinguisher installation and location must be to the satisfaction of the [name withheld] location arrow/label was indicating an old location of extinguisher. Remove arrow to the satisfaction of attending CG Marine Inspector. 46 CFR 181.520
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2021
Resolved 17 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2021 Resolved
Before getting underway or as soon as possible thereafter, the Master shall ensure that a suitable public announcement is made. Develop safety brief to the satisfaction of attending CG Marine Inspector. 46 CFR 185.506
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 2 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2021 Resolved
Alcohol testing devices must be used according to the procedures specified by the manufacturer of the testing device. Alcohol test strips onboard were expired. Procure new test strips. To operate in the interim, make arrangements to ensure a test can be completed within 2 hours of a Serious Marine Incident. 46CFR4.06-3(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2021
Resolved 17 August 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 August 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First-aid kit is missing required items and has expired items. Make kit satisfactory with above requirement and provide proof to attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 19 September 2019
Resolution: Made first aid kit satisfactory and provide proof to Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 August 2019 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. Installed rudder stops are not effective. Make rudder stops satisfactory to above requirement and conduct operational test with an attending Marine Inspector prior to 2020 operating season.
Action required: 705 - Other - as specified
Due 1 June 2020
Resolved 22 July 2021
Resolution: Vessel installed adequate rudder stops. Op tested SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2018 Resolved
Repair cracked port aft deck station to the satisfaction of the attending C. G. Marine Inspector. To be cleared prior to next annual inspection.
Action required: 705 - Other - as specified
Resolved 9 July 2019
Resolution: Repaired cracked port aft deck station to the satisfaction of the attending C. G. Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2018 Resolved
Replace forward bilge pump and demonstrate proper operation of all pumps. Demonstration to include actual pumping of water over the side of vessel. To be cleared prior to next annual inspection.
Action required: 705 - Other - as specified
Resolved 9 July 2019
Resolution: Pump replaced and tested
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2018 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. First aid kit contents expired. Replace required contents of first aid kit with unexpired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2018
Resolution: Replaced all required contents of first aid kit with unexpired items.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 September 2017 Resolved
Perform 3 MOB drills using 3 different licensed Masters under simulated emergency conditions.
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 13 June 2018
Resolution: Successfully performed 03 Man Overboard Drills with 1 Master
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 1 August 2017 Resolved
There were two approved smoke distress signals missing that would need to be replaced
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 5 September 2017
Resolution: SAT
Lifesaving › Lifebuoys › Immediately Available
Issued 1 August 2017 Resolved
Ring life buoy was not easily deployable due to required light being held to railing with wire rope and the life ring being held to the railing with Velcro.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 5 September 2017
Resolution: Original bracket for water light was upside down. Corrected installation and removed velcro/wire, SAT
Documentation › Certificates/Documents › Stability Letter
Issued 2 August 2016 Resolved
Post all pages of vessel's Stability Letter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: Received email photo from POC attesting to posting stability letter.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 August 2016 Resolved
Post Substance Abuse Professional contact information.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: Received email from POC attesting to posting required information.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2016 Resolved
Provide proper contents of first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: Received email from POC providing receipt of CG approved first aid kit.
Electrical › Lighting (service) › Conductor
Issued 2 August 2016 Resolved
Renew broken wire for transome deck LED light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: Received email from POC providing receipt for new deck lighting with statement attesting to installation and operation.

Casualty record · 1

29 September 2012Routine · role: Involved in a Marine Casualty · activity 4453148
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.