MAURY USCG vessel records
← All vessels

GRAND ACE6

GRAND ACE6 is a 2006 tank ship. The Coast Guard has recorded 7 inspections since 2018, most recently in May 2026, along with 2 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 19 May 2026.

Built
2006
Last inspected
19 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 May 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9375329
882228
Flag
PANAMA
Maury page id
psix-882228

Documentation record

Tonnage as PSIX records it46192 - Dead Weight, Metric Ton
56214 - Displacement, Metric Ton
30048 - Convention (Subpart B), Gross Ton
11735 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

19 May 2026 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8376010
3 March 2026 PSC B · Deficiency Check · COC-CHEM & TVE Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8317024
26 February 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8316959
29 December 2024 COC-CHEM Renew · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8050557
2 October 2022 COC-CHEM & TVE Renew · PSC B · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7566781
2 November 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6573198
25 September 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6544147

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2026 Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed wiring to two lighting installations on forward end of cargo deck not installed to acceptable standards. 74 SOLAS (20) II-1/45.11
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2026
Resolution: PSCO verified repair onboard and received class report attesting repairs were in accordance with class rules.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 25 September 2018 Resolved
74 SOLAS (2004) II-2/5.5.1.1 FSS CODE 2.2.1.2.5 For tankers of 20,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the Fire Safety Systems Code. The system shall be capable of: delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. The IG shut-off valve was not working properly.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2018
Resolution: Recieved KRS survey report attesting to the rectification of the noted deficiency.

Ownership record