Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it46192 - Dead Weight, Metric Ton 56214 - Displacement, Metric Ton 30048 - Convention (Subpart B), Gross Ton 11735 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 7
19 May 2026COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8376010
3 March 2026PSC B · Deficiency Check · COC-CHEM & TVE Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8317024
26 February 2026Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8316959
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2026Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed wiring to two lighting installations on forward end of cargo deck not installed to acceptable standards.
74 SOLAS (20) II-1/45.11
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2026
Resolution: PSCO verified repair onboard and received class report attesting repairs were in accordance with class rules.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 25 September 2018Resolved
74 SOLAS (2004) II-2/5.5.1.1
FSS CODE 2.2.1.2.5
For tankers of 20,000 tonnes deadweight and upwards, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the Fire Safety Systems Code. The system shall be capable of: delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. The IG shut-off valve was not working properly.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2018
Resolution: Recieved KRS survey report attesting to the rectification of the noted deficiency.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.