Inspection history · 23
30 January 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8303935
26 November 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8040476
6 November 2024
COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8031576
1 August 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7991730
9 February 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7634633
13 December 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7341579
12 April 2021
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7173781
6 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7169783
20 August 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7038524
1 July 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6998659
1 July 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7000550
29 March 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6933296
18 September 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6814993
31 March 2017
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6112492
25 October 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5913225
23 September 2014
Industry Initiated Exam · DAPI Audit · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4994629
25 August 2011
DAPI Audit · MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4132620
8 October 2010
DAPI Audit · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3879581
27 May 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3487394
30 April 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3487301
14 August 2006
MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2752476
17 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1982275
7 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 143696
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 November 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquids. MI's observed excessive diesel oil in the main bilge of the vessel. Upon further inspection, the source of the accumulated fuel came from a faulty gasket on the aft port fuel tank inspection cover that borders the engine room. Vessel must remove the excessive fuel from the bilge prior to movement.
46 CFR 143.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 November 2024
Resolution: Vessel provided photo of clean bilges
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquids. A fuel leak was observed coming from the inspection cover of the port aft fuel tank at the time of Coast Guard inspection. Vessel must mitigate the fuel leakage from the cover.
46 CFR 143.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2024
Resolution: Fuel tank emptied and taken out of service. Seals replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 December 2021
Resolved
Electrical systems and equipment must minimize system failures and fire and shock hazards. The windings on ship's generators require require thorough cleaning prior to movement.
46 CFR 143.400
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 December 2021
Resolved
Fixed fire-extinguishing systems must be inspected and tested, as required by table 142.240 of this section, in addition to the tests required by §§ 147.60 and 147.65 of subchapter N of this chapter. Installed CO2 system had loose connections and requires inspection by technician.
46 CFR 142.240(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 December 2021
Resolved
The following systems must be equipped with gauges at the machinery location: Main engine RPM. RPM gauges at the machinery station for the engines were inoperable.
46 CFR 143.230(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 December 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 December 2021
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Lagging was insufficient on parts of the exhaust manifold.
46 CFR 143.220(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 December 2021
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Starboard shaft seal has a significant amount of dripping during operation.
46 CFR 143.205(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 December 2021
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. Fire extinguisher was insufficiently secured to flammable locker.
46 CFR 142.225(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 December 2021
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). There was no spanner wrench on board.
46 CFR 181.310(d)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 15 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 December 2021
Resolved
Each lifejacket must be marked in block capital letters with he name of the vessel, and must have a whistle secured by a cord to the lifejacket. Some lifejackets did not have the vessel name, and others did not have a cord for the whistle.
46 CFR 141.340(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2021
Resolved
Each towing vessel must be marked in block capital letters with the name of the vessel. Vessel name on the life buoys needs to be redone.
46 CFR 141.360(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 December 2021
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Items in the first aid kit were expired.
46 CFR 140.365
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 December 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 December 2021
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the COLREGS or 33 CFR part 84. The lower masthead light did not energize.
46 CFR 140.720
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 December 2021
Resolved
The original COI must be framed under glass or other transparent material and posted in a conspicuous place onboard the towing vessel.
46 CFR 136.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 13 December 2021
Resolved
Each towing vessel that operates solely on rivers need not carry survival craft if It is designed for pushing ahead and has a TSMS that contains procedures for evacuating crewmembers onto the tow or other safe location. There were no evacuation procedures kept onboard.
46 CFR 141.305(d)3)(ii)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 13 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 December 2021
Resolved
A vessel must be operated so as to afford protection against hazards to life, property, and the environment. Jacket water hose on generator was covered in duct tape and needs replacing.
46 CFR 140.205
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 April 2021
Resolved
STBD MDE fuel return line has develped minor leak. Vessel issued CG835 allowing transit, requiring final repairs, testing to the satisfaction of the attending marine inspector (MSU Baton Rouge).
Action required: 705 - Other - as specified
Due 6 April 2021
Resolved 12 April 2021
Resolution: Repaired to satisfaction of USCG.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 October 2020
Resolved
46 CFR 143.230(a):Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarm panel on bridge provides no audible for bilge high level, and light in engine room is out.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 November 2020
Resolved 19 October 2020
Resolution: Received tech report stating that power supply was replaced, relay timer, and wheel house sensor. Tests conducted, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2020
Resolved
46 CFR 143.205(a):Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. STBD Main Engine racor fuel filters leaking.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 November 2020
Resolved 19 October 2020
Resolution: Received tech report stating all gaskets were replaced. Tests completed, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 19 October 2020
Resolved
46 CFR 140.610:All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. FWD Hatch gasket damaged/missing.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 November 2020
Resolved 19 October 2020
Resolution: Received pictures of replaced gasket. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 August 2020
Resolved
46 CFR 142.220(a): All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Engine room bilges have approximately 4-6" of oily water, and slop tank is full.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 November 2020
Resolved 19 October 2020
Resolution: Received receipt from fuel services attesting to the pump down, cleaning and pictures of the engine room bilge area. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2020
Resolved
Propulsion machinery must be maintained to ensure proper operation. Vessel experienced a loss of the starboard and port main diesel engine due to unknown causes while in transit resulting in a marine casualty. Prior to movement from current location, provide technician report attesting to cause and satisfactory repair to attending CG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2020
Resolution: Vsl provided tech report. Cleared CG-835.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel reported inoperable port generating resulting in loss of power for approximately 3 minutes due to unknown causes. Vessel currently moored at American Styrenics 166MM, LMR, LA. Vessel to provide technician report attesting to cause and satisfactory repair to attending Coast Guard Marine Inspector prior to movement. 46CFR143.205(a) 60 c
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 March 2020
Resolution: RCVD technician report attesting to replacement of fuel filters and sat test of generators.