← All vessels
S-BREEZE
S-BREEZE is a 2004 freight ship. The Coast Guard has recorded 14 inspections since 2007, most recently in May 2026, along with 16 deficiencies and 3 operational controls.
Records from 2007 to 2026. Most recent: inspection, 25 May 2026.
- Built
- 2004
- Last inspected
- 25 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9317145 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5ZP4
883041
Flag
LIBERIA
—
Maury page id
psix-883041
Inspections, by type
…with no type recorded6
Years with a record
5 calendar years (2007–2026)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it18207 - Convention (Subpart B), Net Ton
52454 - Dead Weight, Ton
60772 - Displacement, Ton
30046 - Convention (Subpart B), Gross Ton
52454 - Dead Weight, Ton
60772 - Displacement, Ton
30046 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
25 May 2026
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8373197
14 May 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8373368
24 July 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7750591
16 August 2021
PSC B · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7285546
3 August 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7269449
3 August 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7277730
3 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4099017
6 January 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3917840
26 May 2007
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2940149
25 May 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2945073
18 May 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2934225
10 May 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2926916
7 May 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2923892
7 May 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2923964
Deficiency record · 16
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 August 2021
Resolved
11102-LIFESAVING-LIFEBOATS ARE REQUIRED TO HAVE 3 LITERS OF FRESHWATER PER PERSON FORTHE CAPACITY OF THE LIFEBOAT.
VESSEL IS REQUIRED TO HAVE A MINIMUM OF 75 LITERS IN EACH LIFEBOAT. [name withheld] 43.175 LITERS PER LIFEBOAT.
74SOLAS(20) III/34
LSA 4.4.8.9
17 A/C
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 3 August 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
13101-MACHINERY-OIL PIPES SHALL BE OF STEEL OR OTHER APPROVED MATERIAL
PSCO OBSERVED SILICONE, WRAPPED IN PLASTIC, WRAPPED IN RAGS ON THE OIL DRAIN LINES FOR THE OIL SCAVEGING SYSTEM.
74SOLAS(20)II-2/4.2.3.1
17 AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
07126-MACHINERY-MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMIBLE LIQUIDS.
PSCO OBSERVED MULITPLE AREAS OF LEAKING AND POOLING OIL ON THE MAIN ENGINE, IN THE PURIFIER SPACE AND IN THE AFT STEERIGN SPACE.
74SOLAS(20) II-2/4.1.1
15 AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
09233-PROPULSION AND AUXILIARY MACHINERY-MACHINERY SHALL BE INSTALLED AND PROTECTED TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD.
PSCO OBSERVED A PUMP IN THE PURIFYING SPACE MISSING A PROPER GUARD ON ROTATING MACHINERY.
74SOLAS(04) II-1/26.1
15 AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
09204-PROPULSION AND AUXILIARY MACHINERY-STEERING GEAR COMPARTMENTS SHALL BE PROVIDED WITH SUITABLE ARRANGEMENTS TO INSURE WORKING ACCESS TO STEERING GEAR MACHINERY AND CONTROLS. THESE ARRANGEMENTS SHALL INCULDE HANDRAILS AND GRATINGS OR OTHER NONSLIP SURFACES.
PSCO OBSERVED NO NONSLIP SURFACING IN THE AFT STEERING ROOM
74SOLAS(04) II-1/29.13.2
40 AC
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 August 2021
Resolved
07105-FIRE SAFETY-STAIRWAS WHEN PENETRATING ONLY A SINGLE DOOR SHALL HAVE SELF DOORS.
PSCO OBSERVED 02 DOORS IN THE STAIRWELL THAT DID NOT CLOSE COMPLETELY, LEAVING A SEVERAL INCH GAP.
74SOLAS(20) II-2/9.2.3.4
15 C
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 6 January 2011
Resolved
0936 - Steering gear - The steering gear compartments shall be provided with suitable arrangements to access steering gear machinery and controls which include handrails and gratings or other nonslip surfaces. It was observed that the vessel did not have handrails, gratings, or nonslip surfaces to provide working access to the #1 and #2 steering gear control arrangement. - SOLAS 74a II-1/29
Lifesaving › Immersion Suits › General
Issued 7 May 2007
Resolved
Crew members failed to put on immersion suits in a timely fashion as required in SOLAS 97 cons ed Part III / 33.1.1.1.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 7 May 2007
Resolved
The Ballast Water Management Plan is not ship specific. There is no record of training being done, the number of tanks on the reporting form are incorrect, the ballast water handling logs are not being used, and the sampling points are not identified. 33CFR151.2035
Operations/Management › Pollution › Control of Garbage
Issued 7 May 2007
Resolved
The garbage management plan is not ship specific. Garbage is mixed throughout the vessel including at the final collection point. MARPOL 73/78 V/9
Documentation › Logs/Records › Oil Record Book
Issued 7 May 2007
Resolved
Updates have not been made in the Oil Record Book as per the new MARPOL changes effective 01JAN07. MARPOL 73/78 Annex 1/17 and Appendix III.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 7 May 2007
Resolved
The sewage treatment plant is not being maintained as per manufacturers required daily/weekly/monthly inspections. The vessel also needs a chlorine test kit to properly maintain the equipment, 33CFR159.121
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 May 2007
Resolved
The vessel's position was not checked as per the passage plan during transit from San Francisco Bay to berth in Stockton, ISM Part A/17.
Lifesaving › Immersion Suits › Quantity
Issued 7 May 2007
Resolved
Immersion suits need to be placed in the forward bosun's store in accordance with SOLAS 2004 (cons ed) III/32.3.3
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 7 May 2007
Resolved
Vessel failed first fire drill , the Crew did not demonstrate familiarity of proper space entry/boundary cooling / securing ventilation or electrical power. There was no firefighting checklist available to the Master to make sure these things were done. The second fire drill was much better, but more training is needed. SOLAS 74am (2004 cons) III/19.3.4.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.