Records from 2021 to 2026. Most recent: inspection, 25 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
6 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 6
25 May 2026
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8373197
14 May 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8373368
24 July 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7750591
16 August 2021
PSC B · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7285546
3 August 2021
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7269449
3 August 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7277730
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 August 2021
Resolved
11102-LIFESAVING-LIFEBOATS ARE REQUIRED TO HAVE 3 LITERS OF FRESHWATER PER PERSON FORTHE CAPACITY OF THE LIFEBOAT.
VESSEL IS REQUIRED TO HAVE A MINIMUM OF 75 LITERS IN EACH LIFEBOAT. [name withheld] 43.175 LITERS PER LIFEBOAT.
74SOLAS(20) III/34
LSA 4.4.8.9
17 A/C
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2021
Resolution: Received Class report attesting to replenishment of water rations.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 3 August 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2021
Resolution: Received Class and Flag report attesting to OCM working properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
13101-MACHINERY-OIL PIPES SHALL BE OF STEEL OR OTHER APPROVED MATERIAL
PSCO OBSERVED SILICONE, WRAPPED IN PLASTIC, WRAPPED IN RAGS ON THE OIL DRAIN LINES FOR THE OIL SCAVEGING SYSTEM.
74SOLAS(20)II-2/4.2.3.1
17 AC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2021
Resolution: Received class report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
07126-MACHINERY-MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMIBLE LIQUIDS.
PSCO OBSERVED MULITPLE AREAS OF LEAKING AND POOLING OIL ON THE MAIN ENGINE, IN THE PURIFIER SPACE AND IN THE AFT STEERIGN SPACE.
74SOLAS(20) II-2/4.1.1
15 AC
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2021
Resolved 11 August 2021
Resolution: Received Class report attesting to replenishment of water rations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
09233-PROPULSION AND AUXILIARY MACHINERY-MACHINERY SHALL BE INSTALLED AND PROTECTED TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD.
PSCO OBSERVED A PUMP IN THE PURIFYING SPACE MISSING A PROPER GUARD ON ROTATING MACHINERY.
74SOLAS(04) II-1/26.1
15 AC
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2021
Resolved 11 August 2021
Resolution: Received Class report attesting to replenishment of water rations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2021
Resolved
09204-PROPULSION AND AUXILIARY MACHINERY-STEERING GEAR COMPARTMENTS SHALL BE PROVIDED WITH SUITABLE ARRANGEMENTS TO INSURE WORKING ACCESS TO STEERING GEAR MACHINERY AND CONTROLS. THESE ARRANGEMENTS SHALL INCULDE HANDRAILS AND GRATINGS OR OTHER NONSLIP SURFACES.
PSCO OBSERVED NO NONSLIP SURFACING IN THE AFT STEERING ROOM
74SOLAS(04) II-1/29.13.2
40 AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 August 2021
Resolved 11 August 2021
Resolution: Received Class report attesting to replenishment of water rations.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 August 2021
Resolved
07105-FIRE SAFETY-STAIRWAS WHEN PENETRATING ONLY A SINGLE DOOR SHALL HAVE SELF DOORS.
PSCO OBSERVED 02 DOORS IN THE STAIRWELL THAT DID NOT CLOSE COMPLETELY, LEAVING A SEVERAL INCH GAP.
74SOLAS(20) II-2/9.2.3.4
15 C
Action required: 15 - Rectify deficiencies by next port
Due 3 August 2021
Resolved 3 August 2021
Resolution: DOOR WAS ADJUSTED PRIOR TO [name withheld].