← All vessels
HYUNDAI GENERAL
HYUNDAI GENERAL is a 1996 freight ship. The Coast Guard has recorded 6 inspections since 2007, most recently in June 2017, along with 3 deficiencies and 1 operational control.
Records from 2007 to 2017. Most recent: operational control imposed, 21 June 2017.
- Built
- 1996
- Last inspected
- 21 June 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9112284 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EZF6
883071
Flag
PANAMA
—
Maury page id
psix-883071
Inspections, by type
…with no type recorded1
Years with a record
3 calendar years (2007–2017)
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it64054 - Convention (Subpart B), Gross Ton
64054 - Simplified, Gross Ton
64054 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 6
21 June 2017
ISPS II Exam · PII Safety Exam · Administrative Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6175881
15 September 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3324455
4 December 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3109347
8 September 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3052591
10 May 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2922320
10 May 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2926794
Deficiency record · 3
Communications › Alarms/Indicators › Fire Alarm
Issued 21 June 2017
Resolved
1002-Fire alarm-The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. 06 of 07 indicating stations in a Category A machinery space did not provide visual or audible alarms. See narrative- SOLAS74(97Cons)II-2/13.1.4
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 21 June 2017
Resolved
2545-Reports of non-conformities-Every company should implement and maintain a safety management system which includes procedures for reporting non-conformities with the provisions of this Code. The ship was aware of the deteriorating indicating stations as evidenced by the temporary repairs, and they failed to report the nonconformity to the company. - SOLAS74(2014Cons)IX/3.1 ISM Code 1.4.4
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 September 2008
Resolved
The emrgency generator would not take an electrical load during testing. Ensure engire room remains manned until emergency generator is repaired. Notify terminal concerning loss of emerency generator and inability to run emergency fire pump iin the event of a emergency. Notify local Fire Department of the same. 60a
SOLAS 74/78 Chpt. II-2 Reg. 43
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.