Records from 1986 to 2026. Most recent: inspection, 29 January 2026.
Documentation record
Registered dimensions (L × B × D)71.1 ft × 25.1 ft × 7.0 ft
Registered tonnagegross 158 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYATES MARINE CONSTRUCTION · SOUTH CHARLESTON, WV, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCOVINGTON, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it158 - Regulatory (Subpart C or D), Gross Ton
83 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
29 January 2026
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8356579
3 March 2025
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8087313
24 February 2025
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8084836
7 November 2024
Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8036857
9 September 2024
Damage Survey · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8001981
28 November 2023
Examination of Repairs · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7830638
29 March 2023
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7658724
29 March 2023
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7663424
8 November 2022
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7591945
2 December 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7361161
13 May 2021
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7195774
12 May 2021
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7933390
15 December 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7117354
11 December 2019
Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6872088
30 November 2018
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6596404
23 October 2018
Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6577613
15 February 2017
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6088284
12 November 2014
Administrative Inspection · DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5023427
11 February 2014
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 4810382
3 February 2011
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3954143
25 January 2010
Industry Initiated Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3673322
9 September 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2191113
7 September 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2190420
7 September 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2192254
8 December 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 125553
18 November 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 146628
16 August 1997
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 783892
26 June 1997
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 5591
8 December 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 199144
8 December 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 386025
8 December 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756358
8 January 1994
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 173317
29 February 1988
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 321693
20 January 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 313877
9 May 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 308787
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2025
Resolved
Master reported that when the stbd main engine was engage at loud noise could be heard coming from the vessel propellers. Divers were contracted and identified the doubler plate on the stbd wheel well was half removed. Vessel was toed to Hebron KY Drydock awaiting repairs. Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and the safety of persons onboard under normal and emergency conditions. Make repairs to the satisfaction of the attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2025
Resolution: Recived report from safety department weld completed and underway stearing test satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 November 2024
Resolved
Vessel lost abaility to steer vessel due to bursted hydraulic hose. Make repairs to the satisfcation of the Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 7 November 2024
Resolved 7 November 2024
Resolution: Recived objective evidence scanned into documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2023
Resolved
Vessel lost wheel after striking large drift debris in the water why conducting fleet operations.
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel is restricted from pushing cargo until repairs are complete. Vessel authorized to transit light boat to Hebron Kentucky for repairs.
Prove proper repair to the satisfaction of the Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2023
Resolved 22 May 2023
Resolution: New shaft and wheel installed. Vessel splashed, full underway operational test conducted. test SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2021
Resolved
Starboard side remote fuel instruction placard missing. Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating
the purpose of the valve and the way to operate it.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 6 December 2021
Resolution: Remote fuel shut off placard replaced. Vessel rep provided photograph.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 December 2021
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
Port engine outboard side oil pressure sending unit leaking oil and a constant rate. Repair/replace fitting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 3 December 2021
Resolution: Oil pressure gauge sending unit replaced. Engine tested no leaks. Photographic evidence provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel suffered damage to their starboard rudder/prop and potentially rudder. Make vessel available to Coast Guard Marine Inspectors for damage survey and prior to conducting operations, make permanent repairs to the satisfaction of attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 26 July 2021
Resolution: Shaft and prop was replaced.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 15 December 2020
Resolved
Vessel does not have installed alarms for monitoring emergency conditions. Each towing vessel must have a reliable means to provide notification when and emergency conditions exist or essential system develops a problem that requires attention. The following alarms must be provided low hydraulic steering fluid level. Alarms must be visible and audible at the operating station and may be a summary alarm. Install all alarms to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2021
Resolved 22 December 2020
Resolution: MI verified audible and visual low level hydraulic steering alarm installed in pilot house.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2019
Resolved
MI observed multiple oil leaks on the starboard generator emanating from the top and rear seals . All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquids. Identify all oil leaks on starboard generator and repair to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 13 December 2019
Resolution: Deficiency rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2019
Resolved
MI observed multiple oil leaks on the port generator emanating from the top and rear seals . All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquids. Identify all oil leaks on port generator and repair to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 13 December 2019
Resolution: Deficiency rectified
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 23 October 2018
Resolved
Hydraulic steering fluid level must be equipped with an alarm.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 27 November 2018
Resolution: Almarm installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 October 2018
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Hydraulic hoses located in steering compartment need chaffing gear.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Chaffing gear added.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 October 2018
Resolved
Port rudder post had loose bolts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Bolts tightened.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 October 2018
Resolved
Port steering rudder rod is chaffing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Added spacer to steering assembly to stop chaffing between two metals.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 October 2018
Resolved
Bulkheads designed to be watertight must be maintained in that condition. Penney-sized hole identified in starboard steering bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Hole repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 October 2018
Resolved
Both port and starboard shaft covers loose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Both shaft covers were tightened and made secure.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 October 2018
Resolved
Battery terminals loose in engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Battery terminals secured.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2018
Resolved
All fire extinguishers should be maintained in their appropiate brackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Fire extinguisher brackets were replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 October 2018
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Generator power supply cable housing held on by zip tie.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2018
Resolved 8 November 2018
Resolution: Power supply properly secured with metal clip.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 12 November 2014
Resolved
Company failed to submit MIS report for 2013, orginial DAPI act# 4958617 the DER told the attending inspector the report was filed and it would be produced at the re-audit inspection however it was confirmed that it had never been filed.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 20 November 2014
Resolution: MIS report send to IO office then fowarded to [name withheld].
Lifesaving
Issued 20 January 1987
Resolved
CG APPROVAL NUMBERS NOT LEGIBLE. 46 CFR 25.25-7
Condition: Unknown
Due 20 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past