Offshore Supply Vessel · Offshore class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named MR ALEX
MR ALEX is a 2007 offshore supply vessel. The Coast Guard has recorded 28 inspections since 2007, most recently in March 2025, along with 80 deficiencies and 1 operational control.
Records from 2007 to 2025. Most recent: operational control imposed, 25 March 2025.
- Built
- 2007
- Last inspected
- 25 March 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 80 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1199276
WDK3052
883320
Flag
UNITED STATES
368041450
Maury page id
psix-883320
Inspections, by type
…with no type recorded2
Years with a record
17 calendar years (2007–2025)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)123.6 ft × 34.0 ft × 12.5 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)123.6 ft × 34.0 ft × 12.5 ft
ITC tonnagegross 430 / net 129
BuilderRAYMOND & ASSOCIATES LLC · BAYOU LA BATRE, AL, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGOLDEN MEADOW, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 April 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it129 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
775 - Displacement, Gross Ton
304 - Dead Weight, Gross Ton
430 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
775 - Displacement, Gross Ton
304 - Dead Weight, Gross Ton
430 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK3052MMSI 368041450 · active · compulsorily equipped · granted 30 May 2018, expires 30 May 2028
WDE3593MMSI 367341340 · expired · compulsorily equipped · granted 5 March 2008, cancelled 5 May 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
25 March 2025
Annual Inspection · MARPOL Annex I Examination · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8100005
26 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7885338
29 June 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7794682
26 April 2023
Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7675648
22 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7416248
5 May 2021
COI Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7189786
20 April 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6941242
21 August 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6790460
21 March 2019
Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6646998
24 May 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6422098
30 April 2018
Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6402638
2 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6137556
27 April 2016
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5863353
11 April 2016
Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5851724
1 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6143406
15 July 2015
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5185411
29 October 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5017837
27 June 2014
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4901344
23 May 2014
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4866459
14 February 2011
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3943441
2 February 2011
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3937699
15 March 2010
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3696112
26 March 2009
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3440642
8 April 2008
Deficiency Check · Initial Certification · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3179145
1 April 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3175445
21 March 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3171009
17 March 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3166396
12 June 2007
Plan Review (Other than "T") · Welding Related Inspections Qualification Testing · Construction Oversight · Initial Construction-Excluding Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3171796
Deficiency record · 80
14 - Pollution Prevention › 141 - MARPOL Annex I › Suspected of discharge violation
Issued 25 March 2025
Resolved
No person may operate an oceangoing ship of less than 400 gross tons unless it has the capacity to retain all oily mixtures or discharge to a reception facility. Vessel has pump capable of discharging oily waste overboard w/o discharge records.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 25 March 2025
Resolved
No mannned ship may operate unless it carries onboard a shipboard oil pollution emergency plan. Vessel does not have a valid NTVRP.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 March 2025
Resolved
Each vessel must comply with 47 part 80. Master does not have marine radio operator license.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 March 2025
Resolved
A person may not emply in a position required to hold an MMC unless they maintain a current medical certificate. Masters medical cert is invalid.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 25 March 2025
Resolved
The owner shall provide clear signs notefying crew of audio/visual survellance. No audio/video signs posted.
46 USC 4901
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 25 March 2025
Resolved
Vessels carrying oil as secondary cargo must have containers suitable for holding waste. Small discharge containment does not have scupper plugs. 705- Prior to Cargo operations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 March 2025
Resolved
The bulkhead in each machinery space must be watertight to bulkhead deck. Pentration for rudder angle indicator through potable water tank is leaking.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 March 2025
Resolved
Each vessel must carry adequate and up to date charts. No chart correction made.
14 - Pollution Prevention › N/A - No Subsystem › VGP: Annual Report
Issued 25 March 2025
Resolved
In compliance with Clean Water Act, vessel must submit vessel general permit. Vessel has not submitted vessel general plan.
Title IX - Vessel Incedental Discharge Act.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 March 2025
Resolved
A Fire Drill must be held on alternating weeks. Fire Drills conducted once a month.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 March 2025
Resolved
Abandon Ship Drill must be held on alternating weeks. Abandon ship drills held once per month.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 25 March 2025
Resolved
EPRIB must be tested monthly. No records of EPIRB testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 March 2025
Resolved
Propulsion systems and their auxillaiary systems are vital systems to survival of vessel. Both generators were initially inoperable and had difficulty starting.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025
Resolved
Inspection of lifesaving appliabce for proper condition of of lifebuoys shall verify fit for service. Port ring buoy wasted at plug.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 3 May 2023
Resolved
All U.S. vessels which engage in domestic voyages are subject to load line.
ABS did not issue load line certificate due to outstanding items:
-Stbd stern void man hole cover needs to be replaced.
-Gasket on engine room emergency hatch needs to be replaced.
-Anchor chain needs to be replaced.
-Dogs on engine room escape door need to be repaired.
46 CFR 42.03-5(b)
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 May 2023
Resolved
Suitable covers must be installed on exposed dangerous places.
Missing exhaust lagging in the passageway leading to the engine room.
46 CFR 127.330
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 May 2023
Resolved
A valid TWIC must be retained by the mariner.
Secondary master did not have a valid TWIC.
46 CFR 10.203
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 May 2023
Resolved
EPIRB inspections must be logged in vessels logbook.
Vessel had not been logging EPRIB tests.
46 CFR 131.565(b)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 May 2021
Resolved
A vessel may use batteries with the capacity for 3 hours of continuous operation as a second source of electricity for the loads identified in 129.130(a)(1). The general alarm did not sound on emergency power; the battery back up was not operational.
46 CFR 129.130
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 May 2021
Resolved
The COI is made to determine whether the vessel is in safe and seaworthy condition to include main and auxiliary machinery. Starboard RPM tachometer did not turn on upon energizing both starboard and port main propulsion engines.
46 CFR 126.430
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2021
Resolved
There must be only one connection to the ground distribution system which must be at the main switchboard. The one of the light bulb on the port ground detector was not operational causing it to be unlit.
46 CFR 129.375
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
Each globe, lens, or diffuser of a lighting fixture must have a high strength guard or be made of high strength material. The globe of a lighting fixture on the starboard bridge wing was cracked.
46 CFR 129.410
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Ship security plan
Issued 20 April 2020
Resolved
(b) The VSP must be submitted to the Commanding Officer, Marine Safety Center, U.S. Coast Guard, 4200 Wilson Boulevard Suite 400, Arlington, VA 22203 for visitors. The plan was expired, submit new plan for approval.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2020
Resolved
(a) Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. One fuel hose on the bow thruster prime mover and two hoses in the engine room were cracked and unserviceable.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 20 April 2020
Resolved
(a) The entire vessel response plan (VRP) must be written in English and, if applicable, in a language that is understood by the crew members with responsibilities under the VRP. NTVRP was expired. Provide updated plan approval.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 April 2020
Resolved
The port engineroom escape door could not be closed watertight and the penetration above the door was not sealed watertight. Adjust the door and seal penetration properly.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 April 2020
Resolved
(a) The owner or operator of an OSV shall make the vessel available for inspection by a marine inspector— damage occurred several years ago to the port side shell while underway. Damage must be fixed at next dry dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 April 2020
Resolved
The forward machinery bulkhead below the deepest load waterline had two unapproved penetrations installed utilizing butterfly valves that were not operable. Ensure proper functionality prior to departure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2020
Resolved
(a) Lifebuoys. Each OSV must carry lifebuoys approved under approval series 160.150 or 160.050 as follows: The vessel was missing two ringbouys, ensure one is installed near the stern of the vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 August 2019
Resolved
VESSEL IS NOT ADEQUATELY MANNED IN ACCORDANCE WITH ITS COAST GUARD ISSUED CERTIFICATE OF INSPECTION. TO WIT, THE VESSEL MATE IS SERVING IN A CAPACITY WHERE SAID MARINER'S HOURS OF OPERATION EXCEED TWELVE. VESSEL MUST COMPLY WITH MANNING REQUIREMENTS OF ITS CERTIFICATE OF INSPECTION NLT 22AUG2019. 46 CFR 126.220
Fire Fighting › Fire Main › Condition
Issued 24 May 2018
Resolved
Pinhole leak found in fire main piping repiared incorrectly. Crop and renew the section of piping to satisfaction of attending CG marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 May 2017
Resolved
Remove slip, trip, and fall hazards including slick mats and loose deck plating from engine room.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 May 2017
Resolved
Remove diesel/oil from bilges.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 May 2017
Resolved
Properly label emergency fuel shut off valves.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 May 2017
Resolved
Provide proper operation of galley emergency light.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 2 May 2017
Resolved
Provide vessel specific emergency instructions.
Construction/Loadline › Penetrations › Gasket
Issued 2 May 2017
Resolved
Replace port emergency hatch gasket/ prove proper operation.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 April 2016
Resolved
Almost all emergency lights failed to activate,required vessel rep to provide satisfactory emergency lights prior to operations.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 27 April 2016
Resolved
Independent smoke detectors failed to actuate. required vessel rep to provide operable smoke detectors.
Lifesaving › Lifefloat › Float-free Link
Issued 27 April 2016
Resolved
weak link was broken and installed incorrectly so that the force required to break the link would be at least twice as much. required vessel rep to replace the broken weak link.
Engineering › Steering Gear System › Rudder
Issued 27 April 2016
Resolved
rudder limited in motion from 35 degrees starboard to 23 degrees port. required vessel rep to diagnose the issue and repair so that the rudder operates from 35 to 30 in less than 28 seconds.
Lifesaving › Lifebuoys › Serviceable
Issued 27 April 2016
Resolved
one ring buoy was flooded with water and one had insufficent retroflective tape. required vessel rep to provided sufficent ring buoys.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 27 April 2016
Resolved
line throwing device was missing one projectile and approximatley half of the 25 required charges. required vessel rep to ensure all required items on the approved inventory list are present.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 April 2016
Resolved
all burn cream on vessel was expired. other required items for the vesel were onboard. Required vessel rep to provide sats
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 27 April 2016
Resolved
Vessel transfer procedures were missing the required line diagram for the vessel's fuel system. Required vessel rep to provide required line diagram
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 April 2016
Resolved
starboard running light casing was broken, exposing the light to the weather and presenting the arc of visibility at the wrong angle. Required vessel rep to repair or replace the light
Communications › Radio Communications › EPIRB
Issued 11 June 2014
Resolved
Hydrostatic release not properly marked with the expiration date.
Navigation › Piloting/Steering › Marine Charts
Issued 11 June 2014
Resolved
Vessel must provide appropriate chart for area of transit, Calcasiea River.
Construction/Loadline › Markings › Load Line Mark
Issued 14 February 2011
Resolved
Mark loadline on port side
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 14 February 2011
Resolved
Mark vessel name on bow and stern.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 14 February 2011
Resolved
Begin logging port departure checks/tests.
Documentation › Logs/Records › Logbook (official)
Issued 14 February 2011
Resolved
Begin logging persons involved in drills.
Lifesaving › Lifefloat › Lifeline
Issued 14 February 2011
Resolved
Stow lines on lifefloats properly and stencil lifefloat/paddles with vessel name
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 February 2011
Resolved
Mark liferings with vessel name/port & renew plug on stbd bridge L/R.
Engineering › Bilge Water Management System › Piping
Issued 14 February 2011
Resolved
C/R lap patch on bilge piping and test for marine inspector.
Engineering › Bilge Water Management System › Piping
Issued 14 February 2011
Resolved
Remove flex piping on bilge piping system and C/R approved piping. Test at operational pressure for marine inspector.
Fire Fighting › Fire Main › Material
Issued 14 February 2011
Resolved
Remove flex piping portion of fire main suction from sea chest and crop in approved piping. Pressure test for MI.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 14 February 2011
Resolved
Double nut shaft packing on stbd shaft.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 14 February 2011
Resolved
Renew E/R battle lantern emergency lighting & demonstrate for MI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 February 2011
Resolved
Renew stbd side lifering waterlight.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 8 April 2008
Resolved
Correct oil transfer procedures as discuseed with inspector
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 8 April 2008
Resolved
Add paint locker and CO2 fixed system to fire control plan
Fire Fighting › Means of Escape › Emergency Lighting
Issued 8 April 2008
Resolved
Correct voltage to emergency lighting & submit repair proposel to marine inspector. Lights are too dim.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 April 2008
Resolved
Raise height of fwd white light on top of pilot house to maintain proper light visability without obstruction.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 8 April 2008
Resolved
Replace mat in front of switchboard with proper rubber mat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 April 2008
Resolved
Mount MARPOL placard
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 April 2008
Resolved
Submit non-vessel response plan to headquarters NLT 15APR08
Construction/Loadline › Structures › Door
Issued 8 April 2008
Resolved
Renew straight pins on water tight doors with shoulder pins as discussed.
Lifesaving › Hand Flares › Storage
Issued 8 April 2008
Resolved
Properly mark disress signal box
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 March 2008
Resolved
The fire control plan approved by [name withheld] dated March 20, 2008 shall be permanently exhibited for the guidance of the master and crew members as required by 46 CFR 131.945 to the satisfaction of the attending marine inspector.
Engineering › Compressed Air System (start air) › Valve
Issued 26 March 2008
Resolved
Provide documentation through manufacturers data sheets that supports that all non standard pneumatic components in the compressed air system such as control valves, check valves, relief valves, and regulators meet the material and design requirements of 46 CFR 128.240(b)(1) or (b)(2) as per MSC Letter E-1-0800655 dated 3/3/08.
Engineering › Fuel Oil Service System › Hose
Issued 26 March 2008
Resolved
Provide documentation through manufacturers data sheets that supports that all flexible non-metallic hoses and fittings in the fuel oil system meet the material and design requirements of 46 CFR 56.60-25(b) in accordance with 46 CFR 128.110(a) as per MSC Letter E-1-0703926 dated 1/4/08.
Fire Fighting › Fire Main › Pressure
Issued 26 March 2008
Resolved
Demonstrate to the satisfaction of the attending marine inspector that the fire pump is capable of delivering a single stream of water from the highest fire hydrant at a pitot tube pressure of 50 psi in accordance with 46 CFR 132.120(a) as per MSC Letter E1-0703926 dated 1/4/08.
Engineering › Steering Gear System › Rudder
Issued 26 March 2008
Resolved
Provide documentation through manufacturers data sheets that supports that all material specifications for the construction of the rudder and post meet the material and design requirements of 46 CFR 128.240(b)(1) or (b)(2) as per MSC Letter E-1-0800655 dated 3/3/08.
Engineering › Electric Propulsion System › Interlock Circuitry
Issued 26 March 2008
Resolved
Demonstrate that the propulsion control system is operable from the pilot house with the capability to disable for local propulsion control. Each propulsion control shall be designed such that no one complete or partial failure of an easily replaceable component of the system will allow the propulsion engine to over speed, or propeller blade pitch to increase in accordance with 46 CFR 130.120
Engineering › Steering Gear System › Piping
Issued 26 March 2008
Resolved
Provide evidence to the marine inspector that all components in the bill of material in Raymond & Associates Dwg, Rev. -, Steering System Schematic, can sustain a maximum allowable working pressure of at least 1250psi in accordance with MSC Letter E2-0702789 dated September 12, 2007.
Engineering › Steering Gear System › Pump
Issued 26 March 2008
Resolved
Provide documentation certified by the manufacturer that the steering gear fuild power pumps are suitable for the intended use in accordance with 46 CFR 58.30-15(f) as per MSC Letter E2-0702789 dated September 12, 2007.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 26 March 2008
Resolved
The trip setting for the Steering HPU in the distribution switchboard does not comply with 46CFR 129.380(e). Panels L-1 and L-2 shall each have main circuit breakers. Since both panels are located on different deck levels from their source of power in Panel P-3, a main circuit breaker will enable emergency control of the power to these panels as per MSC Letter E12-0702789 dated 09/12/2007.
Communications › Alarms/Indicators › General Alarm
Issued 26 March 2008
Resolved
Demonstrate to the attending marine inspector that the contact makers for the general alarm system meet the requirements contained in 46 CFR 113.25-11 and the power supply conforms to 46 CFR 113.25-6 as per MSC Letter E2-0702789 dated September 12, 2007.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 March 2008
Resolved
Demonstrate to the satisfaction of the attending marine inspector that the battery powered emegerency lights illuminate upon loss of AC power and are installed in accordance with 46 CFR 112.39 and 46 CFR 112.43 as per MSC Letter E2-0702789 dated September 12, 2007.