CHARLOTTE JAMES is a 1965 towing vessel. The Coast Guard has recorded 19 inspections since 1998, most recently in June 2025, along with 10 deficiencies and 3 casualty investigations between 2006 and 2018.
Records from 1998 to 2025. Most recent: inspection, 18 June 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)40.0 ft × 18.0 ft × 5.8 ft
Registered tonnagegross 44 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAXON CONSTRUCTION CO INC · TELL CITY, IN, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPITTSBURGH, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton 29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2023Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms for generators and propulsion engines not set manufactures publications. Set alarms to manufacturer recommendations as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Alarms set to manufacturers set points
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 August 2023Resolved
The following systems must be equipped with gauges at the machinery location: (1) main engine RPM. Engine RPM not working on starboard engine. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: RPM guage repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2023Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Generator battery charger connections utilize alligator clips. Remove and install permanent connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Charger system removed from vessel
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 August 2023Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. (1) Means for securing power to engine room ventilation fan is located inside the engine room. Move ventilation fan control to a space outside of the engine room.(2) There is no means to close engine room vents. Install method to close as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Manual shut off installed outside of engine room
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 August 2023Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port generator front has oil leak. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Oil leak repaired and leak cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2023Resolved
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Port side life ring by pilot house missing. Relocate lower level life ring to port side pilot house as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Rife ring installed in proper location
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels. Marine employer has no program in place for random testing for dangerous drugs.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
Resolution: Company enrolled in marine consortium with Spectrum Testing Services
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Elements of the vessel's EAP education program have not been displayed on the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
Resolution: Company created an EAP Policy and posted required information.
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: Personnel records, Safety orientation, Record of drills and instruction, Examinations and tests, Operative navigational safety equipment, Operative navigational safety equipment, Record of inspection of towing gear, Fire-detection and fixed fire-extinguishing. Owner/ Operator has evidence of items being completed but it is not logged in the TVR or log book.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 January 2021Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. The remote fuel oil shut-off valve has not been tested and logged at least once every three months.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
Resolution: Equipment tested and logged as required.
17 August 2006Routine · role: Involved in a Marine Casualty · activity 2763962
4 April 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6167235
5 April 2018Routine · role: Involved in a Marine Casualty · activity 6392618
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 2
M/V BURNING STAR (2006), JILLIAN KATHLEEN MURRAY (2017–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.