Records from 1998 to 2025. Most recent: inspection, 18 June 2025.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 18.0 ft × 5.8 ft
Registered tonnagegross 44 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAXON CONSTRUCTION CO INC · TELL CITY, IN, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPITTSBURGH, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
18 June 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8198435
28 November 2024
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8043066
12 April 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7894284
22 August 2023
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7771146
7 December 2021
COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7348759
16 February 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7141411
27 October 2020
Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7096447
26 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6987513
11 March 2020
Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6941744
31 January 2020
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6902430
6 November 2018
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6575754
5 April 2018
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6392618
4 April 2017
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6167235
16 June 2015
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5154933
23 September 2011
Deficiency Check · Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4155619
17 August 2006
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2763962
19 March 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 288302
20 February 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 413293
11 February 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 412755
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms for generators and propulsion engines not set manufactures publications. Set alarms to manufacturer recommendations as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Alarms set to manufacturers set points
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 August 2023
Resolved
The following systems must be equipped with gauges at the machinery location: (1) main engine RPM. Engine RPM not working on starboard engine. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: RPM guage repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Generator battery charger connections utilize alligator clips. Remove and install permanent connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Charger system removed from vessel
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 August 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. (1) Means for securing power to engine room ventilation fan is located inside the engine room. Move ventilation fan control to a space outside of the engine room.(2) There is no means to close engine room vents. Install method to close as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Manual shut off installed outside of engine room
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 August 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port generator front has oil leak. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Oil leak repaired and leak cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2023
Resolved
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Port side life ring by pilot house missing. Relocate lower level life ring to port side pilot house as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2023
Resolved 22 September 2023
Resolution: Rife ring installed in proper location
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels. Marine employer has no program in place for random testing for dangerous drugs.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
Resolution: Company enrolled in marine consortium with Spectrum Testing Services
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Elements of the vessel's EAP education program have not been displayed on the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
Resolution: Company created an EAP Policy and posted required information.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 January 2021
Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: Personnel records, Safety orientation, Record of drills and instruction, Examinations and tests, Operative navigational safety equipment, Operative navigational safety equipment, Record of inspection of towing gear, Fire-detection and fixed fire-extinguishing. Owner/ Operator has evidence of items being completed but it is not logged in the TVR or log book.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 January 2021
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. The remote fuel oil shut-off valve has not been tested and logged at least once every three months.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 February 2021
Resolution: Equipment tested and logged as required.