Records from 2016 to 2026. Most recent: inspection, 26 March 2026.
Inspection history · 21
26 March 2026
Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8334284
17 October 2025
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8254612
17 October 2025
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 8255257
21 May 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8137998
24 March 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8098878
1 May 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7904787
24 August 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7775934
12 June 2023
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7713124
15 May 2023
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7691125
4 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7575134
20 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7382264
3 February 2021
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7132823
20 January 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7124302
1 October 2020
Drydock Extension · Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7069300
21 January 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6890126
28 November 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6585414
2 October 2018
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6553308
7 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6302387
2 February 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6067887
10 November 2016
Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6041782
27 January 2016
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5800136
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 October 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. MI received notification that vessel was involved in a collision and may require FRP repair. Attendance by a Marine Inspector required to assess damage/repair plan.
46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2025
Resolved 29 October 2025
Resolution: FRP repair completed to satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 May 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Stanchions supporting T top at operating station found cracked.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2025
Resolution: Ground out and rewelded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 May 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port engine dry exhaust lagging breaking apart.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2025
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges:
(b) In a vessel of 12 meters or more in length but less than 50 meters in length:
(ii) A sidelight, 2 miles;
Port running light not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 May 2025
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Container for distress flares not properly marked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2025
Resolved
Each lifejacket must be approved under approval series in subparts 160.002, 160.005, 160.055, 160.115, 160.176, or 160.255 in part 160 of this chapter. The life preserver envelope, or cover, shall be made of cotton drill. The color shall be Indian Orange. Life jackets are sun bleached.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Name of vessel is not clearly legible because new name of vessel was written over old name of vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy was no approval listed and is weathered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
Resolution: Replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Lanyard found weathered.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
Resolution: Replaced with new
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 21 May 2025
Resolved
Fill pipes and sounding pipes must run as directly as possible, preferably in a straight line, from the deck connection to the top of the tank. Such pipes must terminate on the weather deck and must be fitted with shutoff valves, watertight deck plates, or screw caps, suitably marked for identification. Fuel fill not marked with "DIESEL".
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2025
Resolved
A portable hand bilge pump must be provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard. Portable bilge pump discharge hose too short to discharge overboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 21 May 2025
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast placard instructions has incorrect vessel information listed.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 21 May 2025
Resolved
(d) The cockpit must be self-bailing. Scuppers or freeing ports for the cockpit deck of a cockpit vessel must:
(1) Be located to allow rapid clearing of water in all probable conditions of list and trim;
(2) Have a combined drainage area of at least the area required by § 178.450 of this part; and
(3) If the deck is less than 255 millimeters (10 inches) above the deepest load waterline of the vessel, be fitted with non-return devices. Combined drainage area fails to meet the requirements of 46 CFR 178.450.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 28 June 2025
Resolution: Non-return devices removed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 May 2024
Resolved
Vessel did not have Navigation Rules onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 30 March 2026
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 1 May 2024
Resolved
Vessel did not have the required number of portable lights onboard
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 26 March 2026
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2024
Resolved
Starboard bilge alarm indicator light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 26 March 2026
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 May 2023
Resolved
Test high water alarms. Stbd high water alarm light was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 24 August 2023
Resolution: Correcetd.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 May 2023
Resolution: Satisfactory repairs made to stbd aft gunwale.
Construction/Loadline › Hull › Keel
Issued 10 November 2016
Resolved
Repair gel coat in two areas in way of the keel.
Action required: 705 - Other - as specified
Resolved 10 November 2016
Resolution: Gel coat repaired by Diversified Yacht Services.