Records from 2009 to 2026. Most recent: operational control imposed, 3 May 2026.
Inspection history · 50
3 May 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8360762
2 May 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8368640
23 July 2025
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8191061
27 February 2025
Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8085921
7 January 2025
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8059764
7 January 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8060251
9 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8045355
9 December 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8049091
3 December 2024
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042760
15 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7981218
5 April 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7890662
7 March 2024
Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7875779
31 January 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7858841
31 January 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7872997
20 November 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7827464
17 July 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7744797
17 July 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7747843
23 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7656494
1 December 2022
Deadweight Survey · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7603364
28 September 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7566736
21 March 2022
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7415683
2 December 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7361449
2 December 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7363372
24 August 2021
COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7290691
2 August 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7275534
30 March 2021
Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7166872
20 February 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7143501
12 February 2021
Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7139801
4 August 2020
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7023852
6 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6921894
19 November 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6929143
30 October 2019
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7031561
29 July 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6766164
9 February 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6623094
20 November 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6584438
14 November 2018
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6567155
2 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6552945
25 July 2018
Drydock Exam · Internal Structural Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6469881
16 February 2018
Damage Survey · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6357964
22 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6341765
21 November 2017
MTSA/ISPS Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6311083
20 October 2017
Damage Survey · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6291930
17 October 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6290176
17 October 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6324636
21 June 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6182604
8 June 2017
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6169521
1 March 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6097332
26 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5984317
17 August 2016
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5975669
19 May 2016
Plan Review (Other than "T") · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5895309
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 May 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced loss of propulsion on their starboard main engine. Provide root cause and repair issue to the satisfaction of the Marine Inspector.
46 CFR 119.200(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2026
Resolution: MIs attended vessel and observed completion of satisfactory sea trials on newly installed engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2025
Resolved
Replacement of full length of shafts.
Action required: 705 - Other - as specified
Resolved 10 December 2025
Resolution: MI verified installation and shaft alignment (report recevied).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 October 2025
Resolved
Crop and renew hull plating beneath port and starboard generator
Action required: 705 - Other - as specified
Resolved 5 December 2025
Resolution: Operatored replaced wasted metal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 February 2025
Resolved
A hatch exposed to the weather must be watertight...Vessels port/starboard forpeak and port/starboard lazarette hatches have worn gaskets allowing water intrusion. Replace gaskets in 04 hatches.
46 CFR 116.1160(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 26 March 2025
Resolution: Operator sent photos of new gaskets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 February 2025
Resolved
A hatch exposed to the weather must be watertight...Port and starboard lazarette softpatches are leaking, make temp repair to maintain water tight integrity, permanent repair to be made during vessel dry dock.
46 CFR 116.1160(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 March 2026
Resolution: Operator sent photos of temp seal to soft patch.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 January 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel self reported striking a submerged object in SF Bay. Damage is unknown at this time but vessel is taking on water. Vessel is restricted from moving from its current position at the Central Bay WETA facility until temporary repairs are effected to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 January 2025
Resolution: MI witnessed satisfactory repairs and NDT.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 August 2024
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. MI observed cable penetrations in STBD Laz with mixed and torn fire-stop putty. Repair to the satisfaction of the MI.
46 CFR 116.415 (a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 30 August 2024
Resolution: MI received satisfactory photo of repaired fire-stop putty.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Port engine room generator was missing a face plate. Repair to the satisfaction of the MI.
46 CFR 120.200 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 30 August 2024
Resolution: MI received photo of face plate on generator.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 August 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The port engine room contained flammable liquid in an open container. MI observed the removal of the oil from the vessel during the inspection.
46 CFR 115.830 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 August 2024
Resolution: Vessel Rep removed oil during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The vessel experienced a loss of propulsion while transiting to San Francisco, CA. Vessel to identify extent of the issue, root cause and to conduct repairs to the satisfaction of the OCMI.
46 CFR 119.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2024
Resolution: Vessel completed satisfactory seatrial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 January 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced loss of propulsion on their port main engine. Provide root cause and repair issue to the satisfaction of the Marine Inspector.
46 CFR 119.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2024
Resolution: Accepted tech report for repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 November 2023
Resolved
The emergency lighting required must automatically actuate upon failure of the main lighting system. Port and STBD Engine room emergency lights failed to actuate upon loss of normal power.
46 CFR 120.432 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 22 January 2024
Resolution: P/S E Lighting properly actuated upon loss of power.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 20 November 2023
Resolved
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space. Aft STBD vent cover for the
transformer space is not attached properly.
46 CFR 116.600(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 22 January 2024
Resolution: Vent cover properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 20 November 2023
Resolved
Each device must— (1) Be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. Investigate sewage piping for toxic substances leak.
33 CFR 159.95(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 22 January 2024
Resolution: Vessel replaced gasket material of flange above leak.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 20 November 2023
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Sewage void cable transit has unused cables blocking the penetration.
46 CFR 179.320(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 22 January 2024
Resolution: Cable transit properly repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 November 2023
Resolved
Each rescue boat and ring life buoy must be marked with Type II retro reflective material.. Port aft life ring was missing type II retro reflective tape.
46 CFR 122.604 (i)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 January 2024
Resolution: Retro-reflective tape properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Starboard engine began smoking while underway leaving the dock, crew secured starboard engine and returned to the dock under the port engine. Provide report of cause analysis and conduct repairs to the satisfaction of attending Marine Inspector prior to movement.
46CFR119.200(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2023
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 24 August 2021
Resolved
A vessel's stability letter must be posted under glass such that all pages are visible at the operating station of the vessel. Current stability letter not posted in operating station.
Action required: 10 - Deficiency Rectified
Resolved 24 August 2021
Resolution: Vessel printed and posted current stabilty letter.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 24 August 2021
Resolved
The master and crew of a vessel will have mounted at the operating station, emergency instructions containing actions to be taken in the event of fire, flooding, heavy weather, or man overboard. Vessel did not have emergency instruction posted in operating station.
Action required: 10 - Deficiency Rectified
Resolved 24 August 2021
Resolution: Operator printed and mounted instructions in pilot house.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 October 2018
Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 November 2018
Resolution: Vessel rep [name withheld] notified USCG Sector SF of technician work and AIS to be transmitting all vessel specifics as required.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2018
Resolved
Vessel struck an unidentified object resulting in engine vibrations.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2018
Resolved 22 February 2018
Resolution: Operator provided divers' report and conducted satisfactory sea trials.
Construction/Loadline › Hull › Weld
Issued 20 October 2017
Resolved
Vessel reported 4 inch crack along the chine weld on the starboard lazarette.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2017
Resolved 3 November 2017
Resolution: Witnessed satisfactory hull insert.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 June 2017
Resolved
Determine causative factors and prove proper operations of overheating on port engine.46CFR115.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 1 July 2017
Resolution: Replaced freshwater pump conducted sea trials all sat.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 8 June 2017
Resolved
Provide MSC "examined" letter for DVTP/PSTP, make vessel available for testing.
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 22 January 2018
Resolution: DVTP/PSTP Testing Satisfactory following MSC approval.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 26 August 2016
Resolved
Repair exhaust leak on port MDE turbo.
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 15 September 2016
Resolution: Tech report provided showing repair.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 August 2016
Resolved
Provide proper structural fire protection doors used to access emergency fuel shutoffs on main deck control spaces. Vessel restricted to no more than 150 passengers until resolved.
Action required: 705 - Other - as specified
Resolved 1 September 2016
Resolution: NFPA 252 fire rated fire doors installed which replaced plastic doors found during inspection.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 26 August 2016
Resolved
Vessel had emergency lighting onboard which could illuminate paths to emergency embarcation stations, but it was inop. Repair emergency lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2016
Resolved 30 August 2016
Resolution: Emergency lighting now operational.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 August 2016
Resolved
Provide fire control plan showing structural fire protection boundaries.
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 15 September 2016
Resolution: Sat fire/safety plans provided.
Communications › Alarms/Indicators › High Water Alarm
Issued 26 August 2016
Resolved
Provide audible high level bilge alarms that subsequent high level bilge alarms cannot be silenced by acknowledgment of other unrelated alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2016
Resolution: Computer control unit reprogrammed, sat test of high level alarms witnessed.
Communications › Alarms/Indicators › General Alarm
Issued 26 August 2016
Resolved
Vessel is equipped with main space general alarm strobes. Prove proper operation of sbtd engine room general alarm strobe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2016
Resolution: Strobe test satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 August 2016
Resolved
Provide 19 more type I PFD's, vessel restricted to 211 passengers.
Action required: 705 - Other - as specified
Resolved 30 August 2016
Resolution: 230 PFD's now onboard.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 August 2016
Resolved
Provide flashlights near the entrance to both engine rooms.
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 30 August 2016
Resolution: Flashlights provided.
Engineering › Bilge Water Management System › Pump
Issued 26 August 2016
Resolved
Prove proper operation of starboard bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2016
Resolution: Satisfactory test completed.