Records in 2022. Most recent: inspection, 26 July 2022.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 July 2022
Resolved
All THE STEERING GEAR COMPONENTS SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTATION. PSCO OBSERVED STEADY LEAK FROM #1 STEERING HEAR PUMP WHILE RUNNING.
Action required: 10 - Deficiency Rectified
Due 27 July 2022
Resolved 27 July 2022
Resolution: DEFICIENCY WAS FIXED ON THE SPOT. PSCO OBSERVED/TESTED STEERING GEAR PUMP # 1 AND OBSERVED NO LEAKS.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 26 July 2022
No resolution recorded
IF A FIRE IN ANY ONE COMPARTMENT COULD PUT ALL THE PUMPS OUT OF ACTION. THERE SHALL BE AN ALTERNATE MEANS CONSISTING OF AN EMERGENCY FIRE PUMP COMPLYING WITH THE PROVISIONS OF THE FSS CODE. PSCO OBSERVED EXCESSIVE LEAKS FROM THE EMERGENCY FIRE PUMP.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2023 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 26 July 2022
No resolution recorded
SHIPS SHALL BE MAINTAINED IN COMPLIANCE WITH REQUIREMENTS OF A CLASSIFICATION SOCIETY RECOGNIZED BY THE ADMINISTRATION. PSCO OBSERVED SLOW LEAKS DOWN BULKHEAD OF FRAME 3 FROM AFT MORRING WINCH PIPELINES.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2023 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022
No resolution recorded
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. PSCO OBSERVED STEADY DRIP FROM # 1 AUXILARY ENGINE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2023 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 July 2022
No resolution recorded
THE CONIDTION OF THE SHIP AND EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PSCO OBSERVED STEADY SEAWATER LEAK FROM CARGO HOLD WASH WATER DISCHARGE PIPELINE VALVE #30.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 July 2023 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 July 2022
Resolved
IN SPACES WHERE PENETRATION OF OIL PRODUCTS IS POSSIBLE. THE SURFACE OF INSULATION SHALL BE IMPERVIOUS TO OIL. PSCO OBSERVED RIPPED INSOLATION ON FUEL OIL LINES TO MAIN ENGINE. C/O REPLACED LAGGING.
Action required: 10 - Deficiency Rectified
Due 27 July 2022
Resolved 27 July 2022
Resolution: DEFICIENCY RECTIFIED ON THE SPOT BY C/E.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 July 2022
Resolved
07103 - Where Class "A" Divisions are penetrated, such penetrations shall be tested in accordance with the Fire Test Procedures Code. Such penetrations shall be suitably insulated at the same level of the division. A non-insulated bulkhead penetration was found in the Class A boundary between the steering gear flat and the engine room. - 74 SOLAS (04) II-2/9.3-1 - 15ac
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 24 July 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 July 2022
Resolved
07105 - Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. 02 Class "A" fire doors in the machinery space were unable to fully self-close. 06 Additional class "A" fire doors in accommodation spaces were unable to fully self-close. - 74 SOLAS (04) II-2/9.4.2.1 - 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2022
Resolution: 10C - Vessel crew repaired doors prior to USCG departure.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 18 July 2022
Resolved
07117 - External high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high-pressure line failure. 08 of the fuel injector lines were missing the manufacturer's outer sheath and was replaced with insulation and silver duct tape. - 74 SOLAS (04) II-2/4.2.2.5.2 - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 July 2022
Resolution: CONDITION OF CLASS SET
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 July 2022
Resolved
02108 - In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. A/C unit to ECR was not functional.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2022
Resolution: NEW COMPRESSOR INSTALLED ONBOARD
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 July 2022
Resolved
09233 - Machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on-board, due regard being paid to moving parts. Generators were fitted with temporary guards to prevent rotational hazards. Permanent guards should be fitted. - 74 SOLAS (04) II-1/26.1 - 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 July 2022
Resolution: ORIGINAL GUARDS RE-INSTALLED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2022
Resolved
13101 - In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. The main engine has suffered from a persistant jacket water leak causing wastage of the cylinder. The cylinder housing needs to be renewed. - 74 SOLAS (04) II-1/3.1 - 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 July 2022
Resolution: REPLACED GASKET AND O-RINGS ON CYLINDER 6
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2022
Resolved
13199 - Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. The anchor windlass is leaking hydraulic fluid into the containment area. - 74 SOLAS (04) II-1/3-1 - 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 July 2022
Resolution: CONDITION OF CLASS SET
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 July 2022
Resolved
03105 - Cargo hatch cover - such covers shall be weathertight and fitted with gaskets and clamping devices. 2 clamps on the #1 hatch, 1 on the #2 hatch, and 1 clamp on the #3 hold were found broken deteriorated or missing. - ICLL 88/16.1 - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 July 2022
Resolution: CONDITION OF CLASS SET