Records from 2008 to 2025. Most recent: inspection, 15 October 2025.
Inspection history · 23
15 October 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8188317
29 January 2025
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8043207
16 October 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7991481
12 May 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7905703
12 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7738694
23 February 2023
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7618980
30 January 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7620218
27 December 2022
Drydock Extension · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7607040
19 July 2022
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485179
22 April 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7435768
10 August 2021
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7301425
29 July 2021
Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7268991
8 December 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7108777
5 August 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7020567
26 June 2019
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6720682
29 January 2019
Damage Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6616459
11 December 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6589416
18 June 2018
Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6448766
26 May 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6545384
5 May 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6118677
9 January 2017
Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6068164
9 November 2016
Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6038694
27 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5948681
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 October 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Vessels life float had two broken paddles, replace with new paddles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2025
Resolved 23 October 2025
Resolution: Purchased new paddles.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 October 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel guards on port & stbd engines were damages/missing and did not protect against personnel injury. Repair/replace guards on moving machinery to provide adequate protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 23 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 October 2024
Resolved
Each item of lifesaving equipment with an expiration date must be replaced during the annual inspection and repair if the expiration date has passed. Batteries in all float lights are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 October 2024
Resolution: Operator submitted a receipt showing the purchase of replacement batteries for float lights.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 October 2023
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Vessel does not have a pressure gauge installed on the pump outlet or anywhere in the fire main. Provide fitted pressure gauge at the pump outlet and demonstrate pump can produce 50psi to the attending marine inspector.
46 CFR181.300(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: Gauge installed, verified 60psi
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Port engine room motor driven pump pulley guard is damaged and not properly protecting crew members from rotating pulley/belt. Repair/replace guard so it adequately covers rotating parts.
46 CFR 177.960
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: Guard installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 October 2023
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be high and as far inboard in the bulkhead as practicable, and made watertight. Two penetrations in collision bulkhead that previously had cable runs have been left open and no longer watertight. Make unused cable penetrations in collision bulkhead watertight.
46 CFR 179.320(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: Penetrations closed with 4200
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 October 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicator for submersible bilge pump (Rule 2000) in port lazarette space was found inoperable at the operating station. Demonstrate proper operation of automatic indicating light.
46 CFR 182.530(c)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: Light operational
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 October 2023
Resolved
Each survival craft must be ready for immediate use so that crew members can carry out preparations for embarkation and launching in less than 5 minutes. Vessels life-floats are connected in groups of 4 to a single painter line and then connected to each life-float by a line between 5-10ft. This arrangement would hinder crew from manually launching life-floats from atop 2nd deck. Provide adequate length of line from painter to life-float to allow life-floats to be launched without cutting painter lines.
46 CFR 180.130(a)(5)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: Connecting lines to painter line extended
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 October 2023
Resolved
The float-free link required by § 180.130(a)(1) must be: (1) Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant; (2) Of proper strength for the size of the life float or
buoyant apparatus as indicated on its identification tag
Identification tag was found missing on forward painter-line at deck connection. Provide a tag for weak-link.
46 CFR 180.137(b)(2)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 6 November 2023
Resolution: New link installed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 October 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Bilge high level alarms were found to be non-operational in both the port and starboard engine rooms. Crew replaced float switches and demonstrated proper operation.
46 CFR 182.530(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 October 2023
Resolved 13 October 2023
Resolution: Vessel was able to replace and prove proper operation to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 22 July 2022
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the vessel on the port/starboard bow and ther stern of the vessel. Vessel does not have the name of the vessel on the port/starboard side and the stern.
46CFR67.123
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 9 August 2022
Resolution: Vessel Provided objective evidence for correction of deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 July 2022
Resolved
Provide Light List, Tide Table, and Coast Pilot onboard vessel.
Action required: 705 - Other - as specified
Due 22 July 2022
Resolved 22 July 2022
Resolution: Vessel purchased digital copies of all required publications for distribution among crew members.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2022
Resolved
Plug penetrations in fuel tank spaces of port and starboard hulls that lead to forward holds.
Action required: 705 - Other - as specified
Due 22 July 2022
Resolved 22 July 2022
Resolution: Penentrations in forward holds were plugged with 5200.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2022
Resolved
Remove unservicable life jackets from Port side compartment and destroy.
Action required: 705 - Other - as specified
Due 22 July 2022
Resolved 22 July 2022
Resolution: Vessel removed and destroyed all unservicable life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 July 2022
Resolved
The rules concerning shapes shall be complied with by day. Vessel did not have day shape for when anchored.
33CFR83.20
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 9 August 2022
Resolution: Vessel Provided objective evidence for correction of deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Fixed bilge system was not drawing suction. Corrected on scene.
46 CFR 182.500
Action required: 10 - Deficiency Rectified
Resolved 22 April 2022
Resolution: Fixed bilge system corrected on scene.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 August 2021
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. Comapany self -administered drug and alcohol testing program is not in compliance with the chemical testing program regulations. Correct all identified discrepancies to the satisfaction of the attending MI.
Action required: 705 - Other - as specified
Due 10 September 2021
Resolved 23 February 2023
Resolution: Vessel is enrolled with the rest of company boats with Alternative Safety & Testing Solutions consortium.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 July 2021
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet must be fitted with a pressure gauge. During operational test of fire pump, pressure gauge at outlet was only reading 55 psi.
Action required: 10 - Deficiency Rectified
Due 29 July 2021
Resolved 29 July 2021
Resolution: Replaced gauge and verified system pressure to be 60 psi.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 29 July 2021
Resolved
Each vessel that does not comply with 46 CFR § 178.310(c) must have permanent draft marks at each end of the vessel or permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. Vessel missing permanent loading or draft marks.
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 9 March 2023
Resolution: Draft marks applied during drydock period.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 9 January 2017
Resolved
Replace in kind the piping found leaking on the suction side of the MSD tank in the port engine room space.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 12 January 2017
Resolution: New piping installed at the suction piping elbow for the MSD in the port engine room space, replaced previous piping in kind.