MAURY USCG vessel records
← All vessels

TROPIC MARINER

TROPIC MARINER is a 1995 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in April 2026, along with 38 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 9 April 2026.

Built
1995
Last inspected
9 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9110547
884193
Flag
SAINT VINCENT AND THE GRENADINES
Maury page id
psix-884193

Documentation record

Tonnage as PSIX records it2899 - Simplified, Gross Ton
2899 - Convention (Subpart B), Gross Ton
1390 - Simplified, Net Ton
5777 - Displacement, Metric Ton
3950 - Dead Weight, Metric Ton
1390 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

29 inspections, each with its date, unit and type; 38 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

9 April 2026 PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8344688
29 September 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8243325
3 February 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8073847
28 January 2025 Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8070745
16 July 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7957699
8 June 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7930677
23 December 2023 Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7842008
21 June 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7719056
18 August 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7536373
10 February 2022 Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7393697
1 February 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7387108
5 August 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7278048
3 August 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7275846
29 July 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7270404
6 July 2021 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7247139
28 December 2020 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7116615
22 June 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6981225
23 December 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6878204
5 November 2019 Ballast Water Examination · ISPS III Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6849335
14 July 2019 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6749301
6 June 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6705370
9 May 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6679778
11 October 2018 Administrative Inspection · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6557766
6 April 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6386339
13 September 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6265831
13 March 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6103560
9 September 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5986151
29 February 2016 NPV Safety Exam · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5823913
12 January 2016 Deficiency Check · Administrative Inspection · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5795647

Deficiency record · 38

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 April 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During PSC exam, PSCO observed free fall lifeboat steering was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2026
Resolved 11 April 2026
Resolution: CLASS REPORT ATTACHED IN DOCUMENTS
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 9 April 2026 Resolved
In cargo ships of 2,000 gross tonnage and upwards there shall be an alternative means consisting of a fixed independently driven emergency pump which shall be capable of supplying two jets of water to the satisfaction of the administration, during PSC exam PSCO observed insufficient pressure from emergency fire pump to bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2026
Resolved 11 April 2026
Resolution: CLASS REPORT ATTACHED IN DOCUMENTS
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2026 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. During PSC exam, PSCO observed exposed wiring on #1 and #2 generators.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2026
Resolved 11 April 2026
Resolution: CLASS REPORT ATTACHED IN DOCUMENTS
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 September 2025 Resolved
Self-closing fire doors of the same fire integrity standards shall be fitted in the enclosure. PSCO observed fire door in escape hatch fail to self-close. 74SOLAS(04) II-2/13.4.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 October 2025
Resolved 8 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 September 2025 Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ships officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions. PSCO observed missing insulation in the CO2 room overhead which was required to meet A60 boundary as per ships fire plan. 74SOLAS(04) II-2/15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 October 2025
Resolved 8 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed multiple leaking fire hydrants. 74SOLAS(04) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 October 2025
Resolved 8 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2025 Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall illustrate the purpose of thecontrols and the procedures for operating the appliance. PSCO observed operating instructions were no longer visible. 74SOLAS(24) III/9.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 September 2025 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed hold-back hooks in the galley. 74SOLAS(04)II-2/9.4.2.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 September 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 January 2025 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. PSCO observed emergency generator supplying insufficient power. 74 SOLAS (04) II-1/43.2 Code 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2025
Resolution: Vessel provided report of survey from the RO (Bureau Veritas) attesting that following repairs the EDG is supplying sufficient power (voltage 400).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2024 Resolved
In addition to the requirements of paragraphs 1 to 4, the oil fuel and lubricating oil system shall comply with the following: where necessary, oil fuel and lubricating oil pipelines shall be screened or otherwise protected to avoid as far as practicable oil spray or oil leakages on to hot surfaces. PSCOs observed multiple areas throughout the engine room where lagging on fuel lines was degrated. 74SOLAS(1997) Ch. II-2 / Reg. 15.5.1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 July 2024
Resolution: Vessel sent in pictures showing repair of lagging
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 July 2024 Resolved
Doors required to be self-closing shall not be fitted with holdback hooks. PSCOs observed the door to the escape trunk in the engine room held back and unable to close. 74SOLAS(1997) Ch. II-1 / Reg. 47.2
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 16 July 2024
Resolved 16 July 2024
Resolution: Chief engineer removed lanyard holding door open.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2023 Resolved
All ships shall carry at least two emergency escape breathing devices within accommodation spaces. PSCOs observed 05 of the 06 EEBDs onboard are not sufficiently charged. 74SOLAS(20)II-2/13.3.4.2
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2023
Resolution: New EEBDs installed onboard. Class and service reports sent in.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 February 2022 Resolved
Any required fixed pressure water-spraying fire-extinguishing system in machinery spaces shall be provided with spraying nozzles of an approved type. PSCO observed the fixed local water spray over the fuel oil purifiers with one nozzle removed and replaced with an end cap not allowing water to be spread over the diesel purifier. 74 SOLAS (97 cons) II-2/Reg. 10.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2022
Resolved 3 March 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 1 February 2022 Resolved
The structure, machinery and equipment...of a cargo ship as referred to in paragraph(b)(;) shall be subject to the surveys and inspections specified below: an annual survey within 3 months before or after each anniversary date of the Cargo Ship Safety Construction Certificate. Vessel did not have annual endorsement of Cargo Ship Safety Construction Certificate. 74 SOLAS (20 cons.) Ch. 1. Reg 10(a)(iv). 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2022
Resolution: Vessel supplied properly endorsed Cargo Ship Safety Construction Certificate. Uploaded to documents.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 1 February 2022 Resolved
...and may require the master of the ship to certify that the copy is a true copy of such an entry. Any copy so made which has been certified by the master of the ship as a true copy of an entry in the ship's Garbage Record Book. Ship's master failed to sign multiple pages of the Garbage Record Book. MARPOL Annex V/ Reg 10.5. 10c
Action required: 10 - Deficiency Rectified
Resolved 1 February 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 July 2021 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. vessel's load lines marking for TF,T,S,W,WNA need to be painted to match the skin of the vessel leaving only the F line marked in white. No issue with class marking and deck line. ILLC REG 8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2021
Resolution: Vessel submitted photo's with the corrected paint job of the load line markings.
01 - Certificates & Documentation › 012 - Crew Certificates › Application for Endorsement by flagstate
Issued 8 July 2021 Resolved
Administration may... Allow a seafarer to serve for a period not exceeding three months on board a ship entitled to fly its flag while holding an appropiate and valid certificate issued and endorsed as required by another party... Documentary proof shall be readily available that an application for an endorsement has been submitted to the administration. Chief officer flag state endorsement expired on April 21, 2021. An application for endorsement has been submitteed, but has not received a receipt of application for endorsement. 78STCW(17cons)I/10.5
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2021
Resolution: Chief officer recieved his receipt of application for endorsement from Antigua & Barbuda and forwarded to PSCO's email.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 8 July 2021 Resolved
The oil record book... Shall be in the form specified in appendix III to this annex. Chief engineer was not conducting weekly soundings on the dirty oily tank and waste oil tank. MARPOL(17cons) Annex I/17.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 July 2021
Resolution: Master submitted copies of weekly oil record book entries noting the entries for the dirty oil, waste oil tank.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 8 July 2021 Resolved
Every ship 100 gross tonnage and above.. Shall carry a garbage management plan... It shall also designate the person or persons in charge of carrying out the plan. The garbage management plan doesn't designate a person in charge. Additionally it does not include e-waste. MARPOL(17cons)Annex V/10.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 5 August 2021
Resolution: Received email from vessel's agent containing Class Approved new garbage management plan meeting the requirements for MARPOL and applicable MEPCs
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 December 2020 Resolved
Ships constructed before 1JUL2002 shall also comply with part E. Flexible hoses shall be replaced at intervals recommended by the manufacture. The manufactures states to immediately replace damaged parts. Flexible hoses for installed CO2 system were cracked. 74 SOLAS (2014 Cons.) CH II-2 Reg 2.2.2 74 SOLAS (2014 Cons.) CH II-2 Reg 14.2.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2021
Resolved 25 January 2021
Resolution: PSCOs received BV class attestation letter confirming resolution of deficiency to their satisfaction. Report uploaded.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 22 June 2020 Resolved
Crew members with enclosed space entry or rescue responsibilities shall participate in enclosed space and entry and rescue drill to be held on board the ship once every two months. Last recorded enclosed space drill took place on 30MAR2020. SOLAS 74 (2014 CONS) III/19.3.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 June 2020
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 November 2019 Resolved
Every ship of 400 GT and above...shall be provided an oil record book part 1. The ORB...shall be in the form specified in appendix III to this Annex. The current ORB is missing codes specified in appendiz III of MARPOL Annex I. MARPOL (2017 CONS) ANNEX I/17.1; 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 11 November 2019
Resolution: NEW ORB WAS PROVIDED TO THE VESSEL
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 November 2019 Resolved
The ORB shall be completed on each occasion whenever any of the following operations take place...Collection and disposal of oil residue. Entries into the ORB are not being made when oil is transferred from the dirty oil tank to the sludge tank prior to disposal. MARPOL/ (2017 CONS) Annex I/17.2; 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 11 November 2019
Resolution: C/E WAS INSRUCTED ON PROPER USAGE OF THE ORB
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 November 2019 Resolved
...The ORB shall be in the form specified in Appendix III to this Annex. Two tanks identified in the IOPP section 3.1 have not been sounded weekly. (Dirty Oil Tank 4.210 m3 CAP. and Waste Oil 5.02 m3 CAP.). MARPOL/ (2017 CONS) ANNEX I/17.1; 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 11 November 2019
Resolution: C/E WAS PROVIDED TRAINING ON PROPER ENTRIES INTO THE ORB.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2019 Resolved
No flammable liquids may be stored in any accommodation, control, or service spaces (other than a paint locker). PSCO's found diesel bunker samples stored alongside the MSD and in the BOSN store. 46 CFR 147.45 (b)
Action required: 10 - Deficiency Rectified
Due 5 November 2019
Resolved 5 November 2019
Resolution: PSCO's witnessed the crew remove the bunker samples.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 November 2019 Resolved
Ships shall be designed...maintained in compliance with the...classification society recognized by the administration PSCO's observed that the forward bell for the E.R. Alarm was non-operational. Additionally, the ventilation pipe into the paint store is repaired/patched with duct tape. 74 SOLAS(04 CONS) II-1/3-1; 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 11 November 2019
Resolution: WIRING WAS REPLACED, BELL TESTED SATISFACTORILY.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 5 November 2019 Resolved
Every company should develop. Implement and maintain a SMS which includes instructions and procedures to ensure...protection of the environment with relevant legistration. PSCO's observed that the vessel's Chief Engineer is not properly familiarized with completion of the ORB. 74 SOLAS (2014 CONS) IX/Reg. 3 ISM Code 1.4.2; 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 11 November 2019
Resolution: TRAINING WAS PROVIDED TO THE C/E ON MARPOL ANNEX I
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 May 2019 Resolved
07108 - Fire Safety - Fire-fighting appliances shall be kept in good condition and be available for immediate use at all times. The cargo hold quick release CO2 valves had pins to prevent automatic release. Additionally, the manual release operating instructions did not include directions to pull CO2 valve pins prior to discharge. - 74 SOLAS (97 cons.) II/2/21
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2019
Resolved 9 May 2019
Resolution: Technician attended the vessel and inspected the system and placed in working order. They provided training to the crew explaining what the safety pins are for and how to ensure the system in is working condition.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2019 Resolved
07106 - Fire Safety - Cargo spaces shall be fitted with either a fixed fire detection and fire alarm system or a sample. Extraction smoke detection system complying with the requirements of the FSS Code. Cargo hold smoke detection panels on the bridge and forward CO2 room indicate an error. System was tested and operates properly. - 74 SOLAS (14 cons.) II-2/19.3.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 13 June 2019
Resolution: Tech. Report attesting to the satisfactory testing of the system was completed and sent in.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 12 October 2018 Resolved
0715 - DETECTION - CARGO SPACES SHALL BE FITTED WITH EITHER A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM OR A SAMPLE EXTRACTION SMOKE DETECTION SYSTEM COMPLYING WITH THE REQUIREMENTS OF THE FIRE SAFETY SYSTEMS CODE. SMOKE DETECTION SYSTEM FOR CARGO HOLD UNABLE TO ALARM ON BRDIGE PANEL AND IN PANEL IN CO2 ROOM. 74 SOLAS (14) II-2/19.3.3
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2018
Resolved 23 October 2018
Resolution: 23OCT18: received class survey for cargo hold smoke detection system replaced with new unit and operates properly.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 12 October 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2018
Resolved 13 October 2018
Resolution: Vessel submitted class report, attached in documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 12 October 2018 Resolved
0111 - CARGO SHIP SAFETY CONSTRUCTION - THE STRUCTURE AND MACHINERY OF A CARGO SHIP SHALL BE SUBJECT TO A MINIMUM OF TWO INSPECTIONS OF THE OUTSIDE OF THE SHIP'S BOTTOM. ANY TWO SUCH INSPECTIONS SHALL NOT EXCEED 36 MONTHS. VESSEL HAS NO RECORDED INSPECTION OUTSIDE THE SHIP'S BOTTOM IN THE PAST 36 MONTHS. 74 SOLAS (14) I/10(A)(5)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2018
Resolved 13 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 October 2018 Resolved
0750 - FIRE PREVENTION - DOORS SHALL BE REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. PSCO FOUND MULTIPLE SELF-CLOSING DOORS FITTED WITH HOLD-BACK HOOKS. 74 SOLAS (01) II-2/47.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 October 2018
Resolved 12 October 2018
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 April 2018 Resolved
799 - Doors fitted in boundary bulkheads of machinery spaces of catefory A shall be reasonable gastight and self closing. 01 Door leading into the engine room escape trunk was not closing completely. - 74 SOLAS (97 cons.) II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 April 2018
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 6 April 2018 Resolved
9900-Other (not clearly hazardous)- Each loading arm and each transfer pipe-system, including each metallic hose, must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel has not conducted required annual pressure test of transfer pipes- 33CFR156.170(c)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 April 2018
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 9 September 2016 Resolved
01 - 0618 - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 05 minutes. Rescue boat launching davit not working properly resulting in an inability to properly launch the boat. 74SOLAS(97) Ch.III/Reg.14.1
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2016
Resolved 12 September 2016
Resolution: Tech report accepted, def cleared.
Communications › Visual Communication › Signalling Lamp
Issued 9 September 2016 Resolved
02 - 1551 - All ships of 150GT and upwards shall be fitted with a daylight signalling lamp using an energy source of electrical power not solely dependent upon ship's power supply. Backup source of power for daylight signalling lmap failed to operate. 74SOLAS(14Cons.) Ch.V/Reg.19.2.2.2
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 15 September 2016
Resolution: Docs/receipt received, def cleared.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 12 January 2016 Resolved
0669: At least two radar transponders shall be carried on every cargo ship of 500 gross tonnage and upwards. SART in lifeboat found to be expired on DEC 2015. 74 SOLAS (1997 Cons.) Ch.III/Reg.6.2.2
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 14 January 2016