← All vessels
TROPIC MARINER
TROPIC MARINER is a 1995 freight ship. The Coast Guard has recorded 41 inspections since 2007, most recently in April 2026, along with 48 deficiencies and 3 operational controls.
Records from 2007 to 2026. Most recent: inspection, 9 April 2026.
- Built
- 1995
- Last inspected
- 9 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 48 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9110547 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8MM5
884193
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-884193
Inspections, by type
…with no type recorded5
Years with a record
18 calendar years (2007–2026)
The 41 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2899 - Simplified, Gross Ton
2899 - Convention (Subpart B), Gross Ton
1390 - Simplified, Net Ton
5777 - Displacement, Metric Ton
3950 - Dead Weight, Metric Ton
1390 - Convention (Subpart B), Net Ton
2899 - Convention (Subpart B), Gross Ton
1390 - Simplified, Net Ton
5777 - Displacement, Metric Ton
3950 - Dead Weight, Metric Ton
1390 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 41
9 April 2026
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8344688
29 September 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8243325
3 February 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8073847
28 January 2025
Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8070745
16 July 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7957699
8 June 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7930677
23 December 2023
Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7842008
21 June 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7719056
18 August 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7536373
10 February 2022
Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7393697
1 February 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7387108
5 August 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7278048
3 August 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7275846
29 July 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7270404
6 July 2021
Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7247139
28 December 2020
PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7116615
22 June 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6981225
23 December 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6878204
5 November 2019
Ballast Water Examination · ISPS III Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6849335
14 July 2019
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6749301
6 June 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6705370
9 May 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6679778
11 October 2018
Administrative Inspection · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6557766
6 April 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6386339
13 September 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6265831
13 March 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6103560
9 September 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5986151
29 February 2016
NPV Safety Exam · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5823913
12 January 2016
Deficiency Check · Administrative Inspection · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5795647
8 December 2015
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5777234
18 June 2014
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4892440
2 June 2014
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4876916
18 June 2012
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4347487
6 December 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4202656
23 February 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3422468
22 December 2008
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3383549
25 August 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3308734
3 July 2008
NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3255572
14 May 2008
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3206465
14 May 2007
Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2926807
13 May 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2928938
Deficiency record · 48
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 April 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During PSC exam, PSCO observed free fall lifeboat steering was inoperable.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 9 April 2026
Resolved
In cargo ships of 2,000 gross tonnage and upwards there shall be an alternative means consisting of a fixed independently driven emergency pump which shall be capable of supplying two jets of water to the satisfaction of the administration, during PSC exam PSCO observed insufficient pressure from emergency fire pump to bridge.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2026
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. During PSC exam, PSCO observed exposed wiring on #1 and #2 generators.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 September 2025
Resolved
Self-closing fire doors of the same fire integrity standards shall be fitted in the enclosure.
PSCO observed fire door in escape hatch fail to self-close.
74SOLAS(04) II-2/13.4.2.1.1
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 September 2025
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ships officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions.
PSCO observed missing insulation in the CO2 room overhead which was required to meet A60 boundary as per ships fire plan.
74SOLAS(04) II-2/15.2.4.1
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use.
PSCO observed multiple leaking fire hydrants.
74SOLAS(04) II-2/14.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2025
Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall illustrate the purpose of thecontrols and the procedures for operating the appliance.
PSCO observed operating instructions were no longer visible.
74SOLAS(24) III/9.2.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 September 2025
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks.
PSCO observed hold-back hooks in the galley.
74SOLAS(04)II-2/9.4.2.2
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 January 2025
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. PSCO observed emergency generator supplying insufficient power.
74 SOLAS (04) II-1/43.2
Code 17abc
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2024
Resolved
In addition to the requirements of paragraphs 1 to 4, the oil fuel and lubricating oil system shall comply with the following: where necessary, oil fuel and lubricating oil pipelines shall be screened or otherwise protected to avoid as far as practicable oil spray or oil leakages on to hot surfaces. PSCOs observed multiple areas throughout the engine room where lagging on fuel lines was degrated.
74SOLAS(1997) Ch. II-2 / Reg. 15.5.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 July 2024
Resolved
Doors required to be self-closing shall not be fitted with holdback hooks. PSCOs observed the door to the escape trunk in the engine room held back and unable to close.
74SOLAS(1997) Ch. II-1 / Reg. 47.2
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2023
Resolved
All ships shall carry at least two emergency escape breathing devices within accommodation spaces. PSCOs observed 05 of the 06 EEBDs onboard are not sufficiently charged.
74SOLAS(20)II-2/13.3.4.2
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 February 2022
Resolved
Any required fixed pressure water-spraying fire-extinguishing system in machinery spaces shall be provided with spraying nozzles of an approved type. PSCO observed the fixed local water spray over the fuel oil purifiers with one nozzle removed and replaced with an end cap not allowing water to be spread over the diesel purifier.
74 SOLAS (97 cons) II-2/Reg. 10.1
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 1 February 2022
Resolved
The structure, machinery and equipment...of a cargo ship as referred to in paragraph(b)(;) shall be subject to the surveys and inspections specified below: an annual survey within 3 months before or after each anniversary date of the Cargo Ship Safety Construction Certificate. Vessel did not have annual endorsement of Cargo Ship Safety Construction Certificate. 74 SOLAS (20 cons.) Ch. 1. Reg 10(a)(iv). 17ac
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 1 February 2022
Resolved
...and may require the master of the ship to certify that the copy is a true copy of such an entry. Any copy so made which has been certified by the master of the ship as a true copy of an entry in the ship's Garbage Record Book. Ship's master failed to sign multiple pages of the Garbage Record Book. MARPOL Annex V/ Reg 10.5. 10c
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 July 2021
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. vessel's load lines marking for TF,T,S,W,WNA need to be painted to match the skin of the vessel leaving only the F line marked in white. No issue with class marking and deck line.
ILLC REG 8
01 - Certificates & Documentation › 012 - Crew Certificates › Application for Endorsement by flagstate
Issued 8 July 2021
Resolved
Administration may... Allow a seafarer to serve for a period not exceeding three months on board a ship entitled to fly its flag while holding an appropiate and valid certificate issued and endorsed as required by another party... Documentary proof shall be readily available that an application for an endorsement has been submitted to the administration. Chief officer flag state endorsement expired on April 21, 2021. An application for endorsement has been submitteed, but has not received a receipt of application for endorsement.
78STCW(17cons)I/10.5
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 8 July 2021
Resolved
The oil record book... Shall be in the form specified in appendix III to this annex. Chief engineer was not conducting weekly soundings on the dirty oily tank and waste oil tank.
MARPOL(17cons) Annex I/17.1
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 8 July 2021
Resolved
Every ship 100 gross tonnage and above.. Shall carry a garbage management plan... It shall also designate the person or persons in charge of carrying out the plan. The garbage management plan doesn't designate a person in charge. Additionally it does not include e-waste.
MARPOL(17cons)Annex V/10.2
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 December 2020
Resolved
Ships constructed before 1JUL2002 shall also comply with part E. Flexible hoses shall be replaced at intervals recommended by the manufacture. The manufactures states to immediately replace damaged parts. Flexible hoses for installed CO2 system were cracked.
74 SOLAS (2014 Cons.) CH II-2 Reg 2.2.2
74 SOLAS (2014 Cons.) CH II-2 Reg 14.2.2.1
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 22 June 2020
Resolved
Crew members with enclosed space entry or rescue responsibilities shall participate in enclosed space and entry and rescue drill to be held on board the ship once every two months. Last recorded enclosed space drill took place on 30MAR2020. SOLAS 74 (2014 CONS) III/19.3.3
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 November 2019
Resolved
Every ship of 400 GT and above...shall be provided an oil record book part 1. The ORB...shall be in the form specified in appendix III to this Annex. The current ORB is missing codes specified in appendiz III of MARPOL Annex I. MARPOL (2017 CONS) ANNEX I/17.1; 16ac
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 November 2019
Resolved
The ORB shall be completed on each occasion whenever any of the following operations take place...Collection and disposal of oil residue. Entries into the ORB are not being made when oil is transferred from the dirty oil tank to the sludge tank prior to disposal. MARPOL/ (2017 CONS) Annex I/17.2; 16ac
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 November 2019
Resolved
...The ORB shall be in the form specified in Appendix III to this Annex. Two tanks identified in the IOPP section 3.1 have not been sounded weekly. (Dirty Oil Tank 4.210 m3 CAP. and Waste Oil 5.02 m3 CAP.). MARPOL/ (2017 CONS) ANNEX I/17.1; 16ac
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2019
Resolved
No flammable liquids may be stored in any accommodation, control, or service spaces (other than a paint locker). PSCO's found diesel bunker samples stored alongside the MSD and in the BOSN store. 46 CFR 147.45 (b)
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 November 2019
Resolved
Ships shall be designed...maintained in compliance with the...classification society recognized by the administration PSCO's observed that the forward bell for the E.R. Alarm was non-operational. Additionally, the ventilation pipe into the paint store is repaired/patched with duct tape. 74 SOLAS(04 CONS) II-1/3-1; 16ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 5 November 2019
Resolved
Every company should develop. Implement and maintain a SMS which includes instructions and procedures to ensure...protection of the environment with relevant legistration. PSCO's observed that the vessel's Chief Engineer is not properly familiarized with completion of the ORB. 74 SOLAS (2014 CONS) IX/Reg. 3 ISM Code 1.4.2; 16ac
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 May 2019
Resolved
07108 - Fire Safety - Fire-fighting appliances shall be kept in good condition and be available for immediate use at all times. The cargo hold quick release CO2 valves had pins to prevent automatic release. Additionally, the manual release operating instructions did not include directions to pull CO2 valve pins prior to discharge. - 74 SOLAS (97 cons.) II/2/21
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2019
Resolved
07106 - Fire Safety - Cargo spaces shall be fitted with either a fixed fire detection and fire alarm system or a sample. Extraction smoke detection system complying with the requirements of the FSS Code. Cargo hold smoke detection panels on the bridge and forward CO2 room indicate an error. System was tested and operates properly. - 74 SOLAS (14 cons.) II-2/19.3.3
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 12 October 2018
Resolved
0715 - DETECTION - CARGO SPACES SHALL BE FITTED WITH EITHER A FIXED FIRE DETECTION AND FIRE ALARM SYSTEM OR A SAMPLE EXTRACTION SMOKE DETECTION SYSTEM COMPLYING WITH THE REQUIREMENTS OF THE FIRE SAFETY SYSTEMS CODE. SMOKE DETECTION SYSTEM FOR CARGO HOLD UNABLE TO ALARM ON BRDIGE PANEL AND IN PANEL IN CO2 ROOM.
74 SOLAS (14) II-2/19.3.3
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 12 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 12 October 2018
Resolved
0111 - CARGO SHIP SAFETY CONSTRUCTION - THE STRUCTURE AND MACHINERY OF A CARGO SHIP SHALL BE SUBJECT TO A MINIMUM OF TWO INSPECTIONS OF THE OUTSIDE OF THE SHIP'S BOTTOM. ANY TWO SUCH INSPECTIONS SHALL NOT EXCEED 36 MONTHS. VESSEL HAS NO RECORDED INSPECTION OUTSIDE THE SHIP'S BOTTOM IN THE PAST 36 MONTHS.
74 SOLAS (14) I/10(A)(5)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 October 2018
Resolved
0750 - FIRE PREVENTION - DOORS SHALL BE REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. PSCO FOUND MULTIPLE SELF-CLOSING DOORS FITTED WITH HOLD-BACK HOOKS.
74 SOLAS (01) II-2/47.2
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 April 2018
Resolved
799 - Doors fitted in boundary bulkheads of machinery spaces of catefory A shall be reasonable gastight and self closing. 01 Door leading into the engine room escape trunk was not closing completely. - 74 SOLAS (97 cons.) II-2/47.1
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 6 April 2018
Resolved
9900-Other (not clearly hazardous)- Each loading arm and each transfer pipe-system, including each metallic hose, must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel has not conducted required annual pressure test of transfer pipes- 33CFR156.170(c)(4)
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 9 September 2016
Resolved
01 - 0618 - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 05 minutes. Rescue boat launching davit not working properly resulting in an inability to properly launch the boat. 74SOLAS(97) Ch.III/Reg.14.1
Communications › Visual Communication › Signalling Lamp
Issued 9 September 2016
Resolved
02 - 1551 - All ships of 150GT and upwards shall be fitted with a daylight signalling lamp using an energy source of electrical power not solely dependent upon ship's power supply. Backup source of power for daylight signalling lmap failed to operate. 74SOLAS(14Cons.) Ch.V/Reg.19.2.2.2
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 12 January 2016
Resolved
0669: At least two radar transponders shall be carried on every cargo ship of 500 gross tonnage and upwards. SART in lifeboat found to be expired on DEC 2015. 74 SOLAS (1997 Cons.) Ch.III/Reg.6.2.2
Electrical › Electric Generation Source (emergency) › Generator
Issued 2 June 2014
Resolved
0999 - Other Safety General - Each emergency generating set shall be equipped with starting devices approved by Administration. A second source of energy shall be provided unless manual starting can be demonstrated. One of the battery banks provided for the start of the emergency generator was not fully charged to allow the proper start of the emergency generator. -74 SOLAS 04 Con. II-1 Reg 44.2
Communications › Radio Communications › Emergency Source of Power
Issued 2 June 2014
Resolved
1677 - Reserve Source of Energy - The siting and installation of accumulator batteries which provide a reserve source of energy shall be such as to ensure a reasonable lifetime and the highest degree of service. the GMDSS emergency battery is in an encasement that is exposed to the elements.
74 SOLAS 09 Con. IX Reg 13.7.1
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 June 2012
Resolved
0750: Doors required to be self-closing shall not be fitted with hold-back hooks. Stairwell doors all have hold back hooks. Fire plan requires the doors to be self-closing. 97 SOLAS II-2/47.2
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 June 2012
Resolved
1576: All vessels must have the following: US Coast Pilot, USCG Light List, etc. Vessel is missing required publications. 33 CFR 164.33
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 18 June 2012
Resolved
0240: Every seafarer shall hold a valid medical certificate issued in accordance with the pro. regulations. Bosun Arriola, Valentin does not have a valid medical cert. STCW I/9.3
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 18 June 2012
Resolved
1540 On ships 1600 GT and up, a gyro repeater or repeaters shall be provided. On both port and starboard bridge wings, gyro repeaters are inoperable. 97 SOLAS V/ 12.d(ii)
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 August 2008
Resolved
Owner/operator has not received required authorization to operate on the navigable waters of the U.S. Nontank Vessel Response plans must meet the required elements of IAW 33 USC (j)(5)(D) for each Geographic Specific Area in which it operates.
Documentation › Logs/Records › Logbook (official)
Issued 14 May 2007
Resolved
Vessel needs log book for chart corrections
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 14 May 2007
Resolved
Lock missing for CO2 locker. Ned to be placed on and fax receipt to Sector Miami.
Fire Fighting › International Shore Connection › Connection
Issued 14 May 2007
Resolved
International shore connection needs to be put back in place and finger tight bolts.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.