MAURY USCG vessel records
← All vessels

KIRBY 11531

KIRBY 11531 is a 2008 tank barge. The Coast Guard has recorded 15 inspections since 2008, most recently in April 2025, along with 6 deficiencies.

Records from 2008 to 2025. Most recent: inspection, 21 April 2025.

Built
2008
Last inspected
21 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

885225
Flag
UNITED STATES
Maury page id
psix-885225

Inspections, by type

…with no type recorded1
Years with a record 12 calendar years (2008–2025)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC&C MARINE · BELLE CHASSE, LA, UNITED STATES · built 2008
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Net Ton
735 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 15

21 April 2025 Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8116265
8 February 2023 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7634160
2 March 2022 Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · MTSA Verification · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7401263
13 September 2021 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7311446
19 August 2021 Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7291529
19 December 2018 Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6600887
13 December 2017 MTSA Verification · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · COI Inspection · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6323742
5 January 2017 Deficiency Check · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6064989
29 January 2016 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5803400
16 April 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5102782
28 January 2014 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4786967
25 January 2012 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4230704
12 May 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3473139
7 May 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3469535
18 January 2008 Administrative Inspection · Construction Oversight · Internal Structural Exam · Deadweight Survey · Cargo Tank Internal · MTSA Verification · Hull Examination · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130793

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2021 Resolved
Barge sustained damage to deck which extends down to sideshell of the #4 Starboard void wing tank. Authorized transit to repair yard, repair to the satisfaction of USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2021
Resolved 13 September 2021
Resolution: USCG Marine Inspector conducted satisfactory air test and internal inspection of repair.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 January 2017 Resolved
Cargo Authority Attachment includeds Sodium Methylate (SMS) which requires a 4 year cargo tank internal exam. Vessel has not had a CTIE since 2008. Do not carry SMS until a CTIE is conducted by a CG Marine inspector, or remove SMS from CAA. Provide evidence the vessel has not carried SMS since 2008.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 15 February 2017
Resolution: New CAA uploaded by MSC
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 16 April 2015 Resolved
Diesel fuel tank vent wasted to the point of making the flame screen ineffective. The end of the tank vent was wasted, cracked, and exposed to the atmosphere with the flame screen not able to be fully threaded. Replace tank vent to the satisfaction of attending Coast Guard marine inspector.
Action required: 705 - Other - as specified
Due 16 April 2015
Resolved 16 April 2015
Resolution: On the spot correction. Tank vent was replaced to the satisfaction of the attending Coast Guard marine inspector.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 16 April 2015 Resolved
All 3 high-level indicator devices (1-meter rising sticks) were broken and inoperable. Replace all 3 devices to the satisfaction of the attending Coast Guard marine inspector.
Action required: 705 - Other - as specified
Due 16 April 2015
Resolved 16 April 2015
Resolution: On the spot correction. All 3 high-level indicator devices were replaced to the satisfaction of the attending Coast Guard marine inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 May 2009 Resolved
Vessel failed to conduct annual exam.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2009
Resolved 7 May 2009
Resolution: Vessel issued NOV, annual exam completed
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 January 2008 Resolved
Provide valid VRP IAW 33 CFR 155.1030
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.